PubMed Health⌕ Search

Biomedical subjects

Itsuro Saito

Publications and source records attributed to Itsuro Saito.

20 records · Page 2Linked to original sources

Pathophysiologic study of goats with undulation pump total artificial heart: those that survived for more than 1 month.

The undulation pump total artificial heart is an implantable total artificial heart that is being developed at the University of Tokyo. Many advances in our system have been made by the adoption of hardware and software solutions that enabled the animals with the undulation pump total artificial hearts to survive more than 1 month. Pathophysiologic observations were performed for these goats that survived. In this article, the pathophysiologic findings are described in detail for three goats that survived for 46 (goat 9916), 54 (0030), and 63 (0107) days. The microscopic findings indicated that in goat 0107 the histologic changes in key organs occurred at the termination of the experiments. Therefore, the pathophysiologic changes in goats 9916 and 0030 were mainly investigated in this study to evaluate the chronic effect caused by our total artificial heart system. The signs of chronic ischemia and cell dystrophy were observed in both the liver and kidney. Until now, 13 goats had survived more than 1 week and 6 goats survived more than 1 month, including one that survived for 63 days, which is the longest in our experimental series. The pathophysiologic results of goats 9916 and 0030 showed that the undulation pump total artificial heart might still cause some damage to the liver and the kidney. To accomplish long-term survival with the undulation pump total artificial heart, further pathophysiologic studies are required, and the necessary modifications to the total artificial heart system will need to be made.

Animals↗

Functions for detecting malposition of transcutaneous energy transmission coils.

A transcutaneous energy transmission system (TETS) for artificial hearts and ventricular assist devices uses electrical coupling of power between external and implanted coils. If the position of coils changes relative to each other, the TETS cannot feed the required power of the implanted device. During activity or sleep, the coils may move accidentally. TETS users and the people around them have to pay attention to this because the range of the position where the required power can be fed efficiently is not wide. Therefore, we added functions for the position changes of the coils to the TETS. Regular, cautious, and irregular positions were introduced, and the ranges of them were decided upon in our experiments. The cautious position was determined by the area where the change of the relative position of the coils was relatively small. When the coils were in the cautious position, the circuit was tuned by way of changing the resonant point. This modulation could give good power efficiency in the cautious position. When the coils were in the irregular position, an alarm switch was turned on. These functions ease the restriction of the coil position and give better quality of life (QOL) than do the conventional TETS.

Biomedical Engineering↗