PubMed Health⌕ Search

Biomedical subjects

Iulia M Lazar

Publications and source records attributed to Iulia M Lazar.

6 recordsLinked to original sources

Microfluidic liquid chromatography system for proteomic applications and biomarker screening.

A microfluidic liquid chromatography (LC) system for proteomic investigations that integrates all the necessary components for stand-alone operation, i.e., pump, valve, separation column, and electrospray interface, is described in this paper. The overall size of the LC device is small enough to enable the integration of two fully functional separation systems on a 3 in. x 1 in. glass microchip. A multichannel architecture that uses electroosmotic pumping principles provides the necessary functionality for eluent propulsion and sample valving. The flow rates generated within these chips are fully consistent with the requirements of nano-LC platforms that are routinely used in proteomic applications. The microfluidic device was evaluated for the analysis of a protein digest obtained from the MCF7 breast cancer cell line. The cytosolic protein extract was processed according to a shotgun protocol, and after tryptic digestion and prefractionation using strong cation exchange chromatography (SCX), selected sample subfractions were analyzed with conventional and microfluidic LC platforms. Using similar experimental conditions, the performance of the microchip LC was comparable to that obtained with benchtop instrumentation, providing an overlap of 75% in proteins that were identified by more than two unique peptides. The microfluidic LC analysis of a protein-rich SCX fraction enabled the confident identification of 77 proteins by using conventional data filtering parameters, of 39 proteins with p < 0.001, and of 5 proteins that are known to be cancer-specific biomarkers, demonstrating thus the potential applicability of these chips for future high-throughput biomarker screening applications.

Biomarkers, Tumor↗

Mass spectrometric studies on 4-aryl-1-cyclopropyl-1,2-dihydropyridinyl derivatives: an examination of a novel fragmentation pathway.

Examination of the electrospray ionization product ion spectra of 1,2-dihydropyridinyl and 4-aryl-1,2-dihydropyridinyl derivatives bearing a 1-cyclopropyl or 1-trans-2-phenylcyclopropyl group has led to the characterization of unexpected fragment ions. For example, the base peak at m/z 156 present in the product ion spectrum of trans-1-(2-phenylcyclopropyl)-4-phenyl-1,2-dihydropyridine proved not to be the expected 4-phenylpyridinium species but rather the isomeric 3-phenyl-5-azoniafulvenyl species. The results of studies with a series of structural and isotopically labeled analogs require a novel fragmentation pathway to account for the formation of this and related fragment ions. One possible pathway is based on an initial 1,5-sigmatropic shift of a cyclopropylmethylene hydrogen atom that is accompanied by opening of the cyclopropyl ring. The resulting eniminium intermediates then fragment to yield the 5-azoniafulvenyl species.

1-Methyl-4-phenyl-1,2,3,6-tetrahydropyridine↗

Proteome profile of the MCF7 cancer cell line: a mass spectrometric evaluation.

The development of novel proteomic technologies that will enable the discovery of disease specific biomarkers is essential in the clinical setting to facilitate early diagnosis and increase survivability rates. We are reporting a shotgun two-dimensional (2D) strong cationic exchange/reversed-phase liquid chromatography/electrospray ionization tandem mass spectrometry (SCX/RPLC/ESI-MS/MS) protocol for the analysis of proteomic constituents in cancerous cells. The MCF7 breast cancer cell line was chosen as a model system. A series of optimization steps were performed to improve the LC/MS experimental setup, sample preparation, data acquisition and database search protocols, and a data filtering strategy was developed to enable confident identification of a large number of proteins and potential biomarkers. This research has resulted in the identification of >2000 proteins using multiple filtering and p-value sorting. Approximately 1600-1900 proteins had p < 0.001, and, of these, approximately 60% were matched by >or=2 unique peptides. Alternatively, >99% of the proteins identified by >or=2 unique peptides had p < 0.001. When searching the data against a reversed database of proteins, the rate of false positive identifications was 0.1% at the peptide level and 0.4% at the protein level. The typical reproducibility in detecting overlapping proteins across replicate runs exceeded 90% for proteins matched by >or=2 unique peptides. According to their biological function, approximately 200 proteins were involved in cancer-relevant cellular processes, and over 25 proteins were previously described in the literature as putative cancer biomarkers, as they were found to be differentially expressed between normal and cancerous cell states. Among these, biomarkers such PCNA, cathepsin D, E-cadherin, 14-3-3-sigma, antigen Ki-67, TP53RK, and calreticulin were identified. These data were generated by subjecting to MS analysis approximately 42 microg of sample, analyzing 16 SCX peptide fractions, and interpreting approximately 55,000 MS2 spectra. Total MS time required for analysis was 40 h.

Biomarkers, Tumor↗

Microfluidic device for capillary electrochromatography-mass spectrometry.

A novel microfabricated device that integrates a monolithic polymeric separation channel, an injector, and an interface for electrospray ionization-mass spectrometry detection (ESI-MS) was devised. Microfluidic propulsion was accomplished using electrically driven fluid flows. The methacrylate-based monolithic separation medium was prepared by photopolymerization and had a positively derivatized surface to ensure electroosmotic flow (EOF) generation for separation of analytes in a capillary electrochromatography (CEC) format. The injector operation was optimized to perform under conditions of nonuniform EOF within the microfluidic channels. The ESI interface allowed hours of stable operation at the flow rates generated by the monolithic column. The dimensions of one processing line were sufficiently small to enable the integration of 4-8 channel multiplexed structures on a single substrate. Standard protein digests were utilized to evaluate the performance of this microfluidic chip. Low- or sub-fmol amounts were injected and detected with this arrangement.

Electrophoresis, Capillary↗

Multiple open-channel electroosmotic pumping system for microfluidic sample handling.

The development of a novel, fully integrated, miniaturized pumping system for generation of pressure-driven flow in microfluidic platforms is described. The micropump, based on electroosmotic pumping principles, has a multiple open-channel configuration consisting of hundreds of parallel, small-diameter microchannels. Specifically, pumps with microchannels of 1-6 microm in depth, 4-50 mm in length, and an overall area of a few square millimeters, were constructed. Flow rates of 10-400 nL/min were generated in electric-field-free regions in a stable, reproducible and controllable manner. In addition, eluent gradients were created by simultaneously using two pumps. Pressures up to 80 psi were produced with the present pump configurations. The pump can be easily interfaced with other operational elements of a micrototal analysis system (micro-TAS) device with multiplexing capabilities. A new microfluidic valving system was also briefly evaluated in conjunction with these pumps. The micropump was utilized to deliver peptide samples for electrospray ionization-mass spectrometric (ESI-MS) detection.

Electrochemistry↗

Microfabricated devices: A new sample introduction approach to mass spectrometry.

Instrument miniaturization is one way of addressing the issues of sensitivity, speed, throughput, and cost of analysis in DNA diagnostics, proteomics, and related biotechnology areas. Microfluidics is of special interest for handling very small sample amounts, with minimal concerns related to sample loss and cross-contamination, problems typical for standard fluidic manipulations. Furthermore, the small footprint of these microfabricated structures leads to instrument designs suitable for high-density, parallel sample processing, and high-throughput analyses. In addition to miniaturized systems designed with optical or electrochemical detection, microfluidic devices interfaced to mass spectrometry have also been demonstrated. Instruments for automated sample infusion analysis are now commercially available, and microdevices utilizing chromatographic or capillary electrophoresis separation techniques are under development. This review aims at documenting the technologies and applications of microfluidic mass spectrometry for the analysis of proteomic samples.

Biotechnology↗