Analyzing ligand and small molecule binding activity of solubilized GPCRs using biosensor technology.

We used Biacore technology to measure directly the binding of natural ligands and small molecules to the chemokine receptors CXCR4 and CCR5. Both G protein-coupled receptors were solubilized from whole cell pellets and captured on antibody surfaces for analysis. Our solubilization conditions maintained high-affinity binding of chemokines SDF-1alpha and RANTES to CXCR4 and CCR5, respectively. Surface density- and buffer-dependent binding responses, along with binding data for a selective ligand (RCP-168), further validated the biosensor assay. In addition, we showed that it is possible to collect high-quality binding responses for the archetypal small molecule inhibitors JM-2987 and TAK-779. Finally, using our biosensor-based method, we characterized the kinetics of 19 novel small molecule inhibitors of CCR5 and showed that their affinities correlated with values determined for the membrane-associated receptor. Together, the chemokine and small molecule binding data provide evidence that the solubilized receptors maintain native binding properties. These solubilized receptor preparations could be useful reagents for biophysical studies as well as for structural analysis.

Chemokine CCL5↗

A biosensor-based approach toward purification and crystallization of G protein-coupled receptors.

Biacore technology was used to develop an affinity purification method and screen cocrystallization conditions for the chemokine receptor CCR5. We characterized the binding of nine HIV gp120 variants and identified a truncated construct (YU2DV1V2) that bound CCR5 independent of CD4. This construct was used in an affinity purification step to improve the activity of detergent-solubilized receptor by approximately 300%. The biosensor was also used to screen receptor binding activity automatically under 50 different crystallization conditions. We found that high-molecular-weight polyethylene glycols (PEGs 4,000 and 8,000 Da) most often stabilized the receptor and improved complex formation with potential cocrystallization partners such as conformationally sensitive monoclonal antibodies and gp120. Our results show how biosensors can provide unique insights into receptor purification methods and reveal the effects of crystallization conditions on complex formation. Importantly, these methods can be readily applied to other systems.

Antibodies, Monoclonal↗

Kinetic analysis of a high-affinity antibody/antigen interaction performed by multiple Biacore users.

To explore the reliability of Biacore-based assays, 22 study participants measured the binding of prostate-specific antigen (PSA) to a monoclonal antibody (mAb). Each participant was provided with the same reagents and a detailed experimental protocol. The mAb was immobilized on the sensor chip at three different densities and a two-step assay was used to determine the kinetic and affinity parameters of the PSA/mAb complex. First, PSA was tested over a concentration range of 2.5-600 nM to obtain k(a) information. Second, to define the k(d) of this stable antigen/antibody complex accurately, the highest PSA concentration was retested with the dissociation phase of each binding cycle monitored for 1h. All participants collected data that could be analyzed to obtain kinetic parameters for the interaction. The association and the extended-dissociation data derived from the three antibody surfaces were globally fit using a simple 1:1 interaction model. The average k(a) and k(d) for the PSA/mAb interaction as calculated from the 22 analyses were (4.1+/-0.6) x 10(4) M(-1) s(-1) and (4.5+/-0.6) x 10(-5) s(-1), respectively. Overall, the experimental standard errors in the rate constants were only approximately 14%. Based on the kinetic rate constants, the affinity (K(D)) of the PSA/mAb interaction was 1.1+/-0.2 nM.

Antibodies, Monoclonal↗

Solubilization, stabilization, and purification of chemokine receptors using biosensor technology.

Establishing solubilization conditions for membrane-associated receptors is often a tedious empirical process. Here we describe a novel application of SPR biosensor technology to screen solubilization conditions automatically and to assess receptor activity directly. We focus on two chemokine receptors, CXCR4 and CCR5, which are important in HIV cell invasion. The autosampler in Biacore 3000 permitted whole cells expressing C-terminally tagged receptors to be automatically lysed under a given solubilization condition and the lysates to be injected over an antibody surface. The total amount of solubilized receptor could be quantitated from the antibody capture level, whereas the amount of active receptor could be quantitated using a subsequent injection of conformationally sensitive antibody or protein. Using this approach, we identified detergent/lipid/buffer combinations that enhanced and maintained receptor activity. We also used the biosensor to demonstrate CD4-dependent binding of gp120 to solubilized CCR5 and to develop affinity chromatography-based purification methods that increased receptor activity more than 300%. Together, these results illustrate the benefits of using the biosensor as a tool for isolating functional membrane receptors and for analyzing ligand/receptor interactions.

Automation↗

Comparative analyses of a small molecule/enzyme interaction by multiple users of Biacore technology.

To gauge the experimental variability associated with Biacore analysis, 36 different investigators analyzed a small molecule/enzyme interaction under similar conditions. Acetazolamide (222 g/mol) binding to carbonic anhydrase II (CAII; 30000 Da) was chosen as a model system. Both reagents were stable and their interaction posed a challenge to measure because of the low molecular weight of the analyte and the fast association rate constant. Each investigator created three different density surfaces of CAII and analyzed an identical dilution series of acetazolamide (ranging from 4.1 to 1000 nM). The greatest variability in the results was observed during the enzyme immobilization step since each investigator provided their own surface activating reagents. Variability in the quality of the acetazolamide binding responses was likely a product of how well the investigators' instruments had been maintained. To determine the reaction kinetics, the responses from the different density surfaces were fit globally to a 1:1 interaction model that included a term for mass transport. The averaged association and dissociation rate constants were 3.1+/-1.6 x 10(6)M(-1)s(-1) and 6.7+/-2.5 x 10(-2)s(-1), respectively, which corresponded to an average equilibrium dissociation constant (K(D) of 2.6+/-1.4 x 10(-8)M. The results provide a benchmark of variability in interpreting binding constants from the biosensor and highlight keys areas that should be considered when analyzing small molecule interactions.

Acetazolamide↗