A multichannel telemetry system for single unit neural recordings.

We present the design, testing, and evaluation of a 16 channel wearable telemetry system to facilitate multichannel single unit recordings from freely moving test subjects. Our design is comprised of (1) a 16-channel analog front end board to condition and sample signals derived from implanted neural electrodes, (2) a digital board for processing and buffering the digitized waveforms, and (3) an index-card sized 486 PC equipped with an IEEE 802.11b wireless ethernet card. Digitized data (up to 12 bits of resolution at 31.25k samples/s per channel) is transferred to the PC and sent to a nearby host computer on a wireless local area network. Up to 12 of the 16 channels were transmitted simultaneously for sustained periods at a range of 9 m. The device measures 5.1 cm x 8.1 cm x 12.4 cm, weighs 235 g, and is powered from rechargeable lithium ion batteries with a lifespan of 45 min at maximum transmission power. The device was successfully used to record signals from awake, chronically implanted macaque and owl monkeys.

Action Potentials↗

A low power multichannel analog front end for portable neural signal recordings.

We present the design and testing of a 16-channel analog amplifier for processing neural signals. Each channel has the following features: (1) variable gain (70-94 dB), (2) four high pass Bessel filter poles (f(-3 dB)=445 Hz), (3) five low pass Bessel filter poles (f(-3 dB)=6.6 kHz), and (4) differential amplification with a user selectable reference channel to reject common mode background biological noise. Processed signals are time division multiplexed and sampled by an on-board 12-bit analog to digital converter at up to 62.5k samples/s per channel. The board is powered by two low dropout voltage regulators which may be supplied by a single battery. The board measures 8.1 cm x 9.9 cm, weighs 50 g, and consumes up to 130 mW. Its low input-referred noise (1.0 microV(RMS)) makes it possible to process low amplitude neural signals; the board was successfully tested in vivo to process cortically derived extracellular action potentials in primates. Signals processed by this board were compared to those generated by a commercially available system and were found to be nearly identical. Background noise generated by mastication was substantially attenuated by the selectable reference circuit. The described circuit is light weight and low power and is used as a component of a wearable multichannel neural telemetry system.

Amplifiers, Electronic↗

Evaluation of spike-detection algorithms for a brain-machine interface application.

Real time spike detection is an important requirement for developing brain machine interfaces (BMIs). We examined three classes of spike-detection algorithms to determine which is best suited for a wireless BMI with a limited transmission bandwidth and computational capabilities. The algorithms were analyzed by tabulating true and false detections when applied to a set of realistic artificial neural signals with known spike times and varying signal to noise ratios. A design-specific cost function was developed to score the relative merits of each detector; correct detections increased the score, while false detections and computational burden reduced it. Test signals both with and without overlapping action potentials were considered. We also investigated the utility of rejecting spikes that violate a minimum refractory period by occurring within a fixed time window after the preceding threshold crossing. Our results indicate that the cost-function scores for the absolute value operator were comparable to those for more elaborate nonlinear energy operator based detectors. The absolute value operator scores were enhanced when the refractory period check was used. Matched-filter-based detectors scored poorly due to their relatively large computational requirements that would be difficult to implement in a real-time system.

Action Potentials↗

Two multichannel integrated circuits for neural recording and signal processing.

We have developed, manufactured, and tested two analog CMOS integrated circuit "neurochips" for recording from arrays of densely packed neural electrodes. Device A is a 16-channel buffer consisting of parallel noninverting amplifiers with a gain of 2 V/V. Device B is a 16-channel two-stage analog signal processor with differential amplification and high-pass filtering. It features selectable gains of 250 and 500 V/V as well as reference channel selection. The resulting amplifiers on Device A had a mean gain of 1.99 V/V with an equivalent input noise of 10 microV(rms). Those on Device B had mean gains of 53.4 and 47.4 dB with a high-pass filter pole at 211 Hz and an equivalent input noise of 4.4 microV(rms). Both devices were tested in vivo with electrode arrays implanted in the somatosensory cortex.

Action Potentials↗