A 65-year-old female was first treated under a diagnosis of rheumatoid arthritis at the age of 62 years. Just after subcutaneous rheumatoid nodules appeared, she suddenly complained of shortness of breath and vomiting. The diagnosis was overt congestive heart failure with complete atrioventricular block and severe mitral regurgitation. She was treated with temporary pacing, and a permanent pacemaker was implanted 1 month later. She suffered recurrence of congestive heart failure and died 8 months later. Autopsy revealed a giant rheumatoid nodule located on the mitral valve and extending to the atrioventricular node. Presumedly this solitary giant nodule had induced complete atrioventricular block and severe mitral regurgitation.
In patients with implanted DDD pacemaker, cardiac output is maximal when atrioventricular (AV) delay is set to give the maximum QT interval (QTI). QTI is used as a sensor of a rate-responsive pacemaker and the evoked QTI (eQTI) is measured as the time duration from the ventricular pace-pulse and the T sense point, which is the steepest point of the intracardiac T wave. The relationship between the changes in eQTI according to AV delay variations and cardiac function was studied in 13 patients (74.2+/-9.3 [SD] years old) with an implanted QT-driven DDDR-pacemaker. A special software module was downloaded into the pacemaker memory and a personal computer equipped with the special software was connected to the programmer for eQTI date-logging. AV delay was set at 100, 120, 150, 180 and 210 ms. Delta eQTI was defined as maximal eQTI - minimal eQTI. The ejection fraction (EF) was measured by echocardiography. When the AV delay was prolonged, eQTI gradually increased and reached a peak, and then decreased. Delta eQTI in patients with reduced cardiac function (EF <40%) was significantly greater than that in normal cardiac function (EF >55%, 7.6+/-4.9 vs 2.7+/-9.8 ms, p<0.05). There was significant negative correlation between EF and delta eQTI (r=-0.63, p<0.05). The peak of changes in eQTI according to AV delay variations was steeper in patients with reduced cardiac function than in those with normal cardiac function. In conclusion, changes in eQTI according to AV delay variation are greater in patients with reduced cardiac function than in those with normal cardiac function, and the AV delay that gives the maximal eQTI can be easily determined in patients with reduced cardiac function.
QT interval (QTI) may change when cardiac function is improved by optimizing the AV delay. QTI is used as the sensor for rate responsive pacemakers. Evoked (e)QTI is measured as the time duration from the ventricular pace-pulse to the T sense point, which is the steepest point of the intracardiac T wave. The relationship between AV delay and eQTI and cardiac function was studied in 13 patients (74.2 +/- 9.3 [SD] years old) with an implanted QT-driven DDDR pacemaker. A special pacemaker software module was downloaded into the pacemaker memory for eQTI data logging. AV delay was set at 100, 120, 150, 180, 210, and 240 ms. Cardiac output (CO) was measured by continuous Doppler echocardiography. eQTI was 343.3 +/- 22.4, 345.1 +/- 22.5, and 343.4 +/- 23.2 ms (P < 0.01, repeated ANOVA) and CO was 4.2 +/- 0.8, 4.6 +/- 0.8, and 4.2 +/- 0.8 L/min (P < 0.0001, repeated ANOVA) when AV delay was set at the AV delay shortened by one step (AV[-]) and prolonged by one step (AV[+]) from the AV delay at which QT interval was maximum (AV[max]) in seven patients, in whom the peak AV delay at which the eQTI was maximal could be identified. eQTI decreased from 341.1 +/- 20.9 to 339.4 +/- 21.1 ms (P < 0.0001) and CO decreased from 4.4 +/- 1.4 to 4.1 +/- 1.3 L/min (P < 0.005) when AV delay was prolonged from AV(max) to AV(+) in all patients. eQTI decreased from 345.1 +/- 22.5 to 343.3 +/- 22.4 ms (P < 0.0005) and CO decreased from 4.6 +/- 0.8 to 4.2 +/- 0.8 L/min (P < 0.05) when AV delay was shortened from AV(max) to AV(-) in seven patients. Thus, CO was maximal when AV delay was set at the AV delay at which eQTI was maximal. In conclusion, the optimal AV delay can be predicted from the eQTI sensed by an implanted pacemaker, and automatic setting of the optimal AV delay can be achieved by the QT sensor of an implanted pacemaker.