PubMed Health⌕ Search

Biomedical subjects

Izzet Erdinler

Publications and source records attributed to Izzet Erdinler.

16 recordsLinked to original sources

Long-term effects of cardiac resynchronization therapy on heart rate and heart rate variability.

Congestive heart failure is characterized by significant autonomic dysfunction. Development of left bundle branch block in congestive heart failure is a predictor of worse outcome. There are several lines of evidence that cardiac resynchronization therapy (CRT), by biventricular stimulation in patients with severe heart failure and left bundle branch block, improves autonomic functions which can be quantified by measuring heart rate variability. The aim of the present study was to assess the effect of CRT on autonomic functions quantified by heart rate variability and mean heart rate (HR) in patients with advanced heart failure and left bundle branch block in short and long-term follow-up. A total of 35 patients with systolic heart failure and left bundle branch block (mean-age 60 +/- 11 years; 24 male and 11 female; mean left ventricular ejection fraction [EF]: 22.3 +/- 3%) were enrolled. Clinical assessment and echocardiographic examination were performed at baseline and every three months. Continuous electrocardiographic monitorization by 24-hour Holter recordings was performed pre-implantation, 3 months and 2 years after implantation. Mean HR and one of the time-domain parameters of heart rate variability, standard deviation of the R-R intervals (SDNN) were measured. CRT was associated with a decrease in the mean duration of QRS, and an increase in diastolic filling time, the rate with which the left ventricular pressure rises (dP/dt), and left ventricular ejection fraction. Decrease in mean heart rate and increase in SDNN were statistically significant in the third month and second year recordings when compared to baseline recording (p values were < 0.001 for both). In conclusion, CRT with biventricular pacing provides sustained improvement in autonomic function in patients with advanced heart failure and left bundle branch block.

Female↗

Influence of atrioventricular nodal reentrant tachycardia ablation on right to left inter-atrial conduction.

BACKGROUND: Radiofrequency (RF) catheter ablation is the procedure of choice for the potential cure of atrioventricular nodal reentrant tachycardia (AVNRT) with high success rates. We hypothesed that as a result of the close proximity of Koch's triangle and low inter-atrial septal fibers, the RF ablation applied at this region may result in prolongation of inter-atrial conduction time (IACT). METHODS: RF ablation of AVNRT was performed by conventional technique. IACT was measured before and 20 minutes after RF ablation during sinus rhythm. Number of ablations given and duration of ablation were noted. RESULTS: The study group was consisted of 48 patients (36 [75%] female, 12 [25%] male, mean age 43.4 +/- 14. 5 years). RF ablation was successful in all patients. Mean RF time was 4. 0 +/- 3. 3 minutes and mean number of RF was 11. 9 +/- 9, 8. The mean IACT was 70.1 +/- 9.0 ms before ablation and 84.9 +/- 12.7 ms after ablation, which demonstrated a significant prolongation (p<0.001). The prolongation of IACT was very well correlated with the number of (r=0.897, p<0.001) and duration of RF (r=0.779; p<0.001). CONCLUSIONS: RF ablation of AVNRT results in prolongation of IACT. The degree of prolongation is associated with the duration and number of RF ablations given. The relationship between this conduction delay and late arrhythmogenesis need to be evaluated.

Journal Article↗

Adrenal adenoma presenting with ventricular fibrillation.

We report the case of a 58-year-old man who presented with ventricular fibrillation. The serum potassium level was 1.8 mEq/L after successful cardioversion. Coronary angiography showed a normal heart with no structural defects, but 12-lead electrocardiography showed indications of left ventricular hypertrophy, which was confirmed by echocardiography. Laboratory examinations showed a suppressed renin level and an elevated serum aldosterone level. Computed tomography then revealed a right adrenal mass. The patient was treated with surgical resection of the adenoma. This case emphasizes the importance of meticulous search for secondary causes of hypertension, before the occurrence of serious complications.

Adenoma↗

Sequential evaluation of left ventricular systolic and diastolic function after radiofrequency catheter ablation.

Radiofrequency (RF) catheter ablation has become standard therapy for many types of arrhythmias. RF energy may cause deterioration in left ventricular function by damaging the myocardium. The aim of the present study was to assess the changes in left ventricular function after catheter ablation using various echocardiographic parameters. Forty patients (22 women), aged 37 +/- 14 years (range, 15-76 years), underwent catheter ablation for various tachycardias. Routine echocardiogaphic examination was done in all patients. Left ventricular systolic function was evaluated by the modified Simpson method and tissue Doppler. With regard to left ventricular diastolic function parameters, diastolic early (E) and late (A) transmitral filling velocities, deceleration time (DT), isovolumetric relaxation time (IVRT), and tissue Doppler parameters were assessed. All ventricular function parameters were assessed before, and 1 hour, 1 day, and 1 month after the catheter ablation procedure. To avoid any influence of heart rate on diastolic function parameters, the E/A ratio, DT, and IVRT were adjusted to heart rate (cE/A, cDT, cIVRT). No changes in left ventricular systolic function after the ablation were observed. After the ablation procedure (1 hour, 1 day, and 1 month) the cE/A ratio decreased from 1.42 +/- 0.43 to 1.19 +/- 0.40, 1.18 +/- 0.40, and 1.30 +/- 0.33 (P = 0.009), respectively. cDT increased from 210 +/- 54 to 272 +/- 64, 255 +/- 60, 240 +/- 64 (P = 0.001), respectively. Likewise cIVRT increased from 113 +/- 22 to 133 +/- 54, 123 +/- 27, 117 +/- 19 (P = 0.007), respectively. Significant changes were also observed concerning tissue Doppler parameters in assessing diastolic function. Although no significant changes were observed in systolic function after RF ablation, this procedure may have some detrimental effects on ventricular diastolic function para-meters.

Adolescent↗

Asystole associated with cluster headache.

A 43-year-old man with asystole and syncope occurring during cluster headache attacks is reported. The asystole and syncope attacks disappeared completely following prophylactic therapy with methysergide maleate. To the authors' knowledge, the present case is unique in associating asystole with cluster headache attacks and may be due to hyperactivity of the parasympathetic system.

Adult↗

An unusual cause of reflex cardiovascular syncope: vagal paraganglioma.

Vagal paraganglioma is one of the rare tumors of the neuroendocrine system. We are reporting a vagal paraganglioma case presented with uncommon features of the disease: asystole and syncope. Syncope episodes occurred 3 years before the major symptoms of the disease. Dual chamber pacemaker failed to prevent syncope attacks because of the vasodepressor component. The patient was treated successfully with en bloc removal of tumor and vagal nerve. Syncope episodes disappeared after operation.

Adult↗

New-onset conduction defects and their relationship with in-hospital major cardiac events in unstable angina pectoris.

BACKGROUND: The aim of this prospective cohort study was to describe the incidence and the risk factors for the development of intraventricular conduction defects and the relationship of these defects with in-hospital major cardiac events (MACE) in unstable angina pectoris. METHODS: Two-hundred-and-seventy consecutive patients presenting with Braunwald class IIIB angina without a conduction defect at admission were included in the study and followed up during the in-hospital period. RESULTS: Fifty-one patients who developed non-ST-elevation myocardial infarction during the first day were excluded from the study. Of the remaining 219 patients, 40 (18%) had a new permanent conduction defect (group 1) and 179 (82%) did not have a conduction defect (group 2) during the in-hospital period. The patients in group 1 were significantly older (mean age of 63.5 +/- 11 years compared with 59 +/- 10 years, P = 0.01) and a history of previous coronary artery bypass grafting (CABG) was more frequent in this group (12.5% compared with 1.6%, P = 0.004). By logistic regression analysis, age (P = 0.01, odds ratio (OR) = 1.473, 95% confidence interval (CI) = 1.108-2.612) and previous CABG (P = 0.005, OR = 3.995, 95% CI = 1.811-7.383) were also found to be risk factors for the development of a conduction defect. In-hospital total MACE, death and heart failure were more frequently observed in group 1 (P = 0.005, P = 0.02, P = 0.001, respectively). The incidences of recurrent refractory angina, acute myocardial infarction and urgent revascularization were not different between the groups. ST-segment depression at admission (P = 0.009, OR = 1.654, 95% CI = 1.228-2.675) and a new-onset conduction defect (P = 0.02, OR = 1.625, 95% CI = 1.244-2.754) were found to be predictors of the development of in-hospital MACE. CONCLUSIONS: In unstable angina pectoris, patients with a new-onset conduction defect are relatively older and have more frequently undergone previous CABG. Because in-hospital MACE, death and heart failure are more common in patients with a new conduction defect, they should be considered as high risk and treated more aggressively.

Aged↗

Echocardiographic prediction of long-term response to biventricular pacemaker in severe heart failure.

BACKGROUND: Biventricular pacing substantially improves LV systolic function and symptom status in some patients with dilated cardiomyopathy. AIMS: To assess whether the long-term benefit could be predicted from the echocardiographic parameters. METHODS AND RESULTS: Sixteen patients with dilated cardiomyopathy who underwent atrio-biventricular pacemaker implantation were analyzed in two groups: the responders (n=11) were those with a symptomatic improvement of one or more NYHA functional class; the non-responders (n=5) failed to improve at follow-up (7.6+/-5 months). Echocardiography was performed at baseline, the day after the implantation and then every 3 months. Besides the conventional parameters, the following variables were included: LV diastolic filling time (DFT); the duration of mitral regurgitation (dMR); and LV dP/dt obtained from the continuous wave mitral regurgitation curve. While the baseline DFT and dP/dt were not significantly different between non-responders and responders (256+/-105 vs. 358+/-115, P=0.14 and 564+/-199 vs. 468+/-117, P=0.44, respectively), the QRS width (149+/-15 vs. 175+/-24 ms, P=0.05) and the dMR (343+/-70 vs. 443+/-49 ms, P=0.007) were higher in the responders. The changes of dMR, DFT and QRS width by pacing were not significantly different between groups (P=0.18, 0.30 and 0.77, respectively). However, the change of LV dP/dt by pacing in the responders was significantly different than for non-responders (from 468+/-117 to 676+/-216 mmHg/s vs. from 564+/-199 to 483+/-94, P=0.002). An acute increase in LV dP/dt over 22% by pacing yielded only two false negatives and no false positives in predicting the long-term responsiveness. CONCLUSION: Patients with longer QRS and dMR are more likely to benefit from atrio-biventricular stimulation. The acute changes of Doppler derived LV dP/dt may provide valuable information in predicting the long-term response to biventricular pacing.

Aged↗

Differentiation of narrow QRS complex tachycardia types using the 12-lead electrocardiogram.

BACKGROUND: Previous studies have shown that only 80% of narrow QRS supraventricular tachycardia (SVT) types can be differentiated by standard 12-lead electrocardiographic (ECG) criteria. This study was designed to determine the value of some new ECG criteria in differentiating narrow QRS SVT. METHODS AND RESULTS: 120 ECGs demonstrating paroxysmal narrow QRS complex tachycardia (QRS < or = 0.11 ms and rate > 120 beats/min) were analyzed. Forty atrioventricular reciprocating tachycardia (AVRT), 70 atrioventricular nodal reentrant tachycardia (AVNRT), and 10 atrial tachycardia defined with electrophysiologic study (EPS) consisted the study group. Eight surface ECG criteria were found to be significantly different between tachycardia types by univariate analysis. P waves separate from the QRS complex were observed more frequently in AVRT (70%) and atrial tachycardia (80%). Pseudo r' deflection in lead V(1), pseudo S wave in inferior leads, and cycle length alternans were more common in AVNRT (55, 20, and 6%, respectively). QRS alternans was also present during AVRT (28%). ST-segment depression (> or = 2 mm) or T-wave inversion, or both, were present more often in AVRT (60%) than in AVNRT (27%). During sinus rhythm, manifest preexcitation was observed more often in patients with AVRT (42%). When a P wave was present, RP/PR interval ratio > 1 was more common in atrial tachycardia (90%). By multivariate analysis, presence of a P wave separate from the QRS complex, pseudo r' deflection in lead V(1), QRS alternans, preexcitation during sinus rhythm, ST-segment depression > 2 mm or T-wave inversion, or both, were independent predictors of tachycardia type. CONCLUSIONS: Several new ECG criteria may be useful in differentiation of SVT types. Prediction of mechanism prior to EPS may provide additional benefits concerning the fluoroscopic exposure time and cardiac catheterization procedure.

Adolescent↗

Left circumflex coronary artery bridging.

Myocardial bridging most frequently occurs on the left anterior descending coronary artery and may cause ischemia and related complications. Right coronary artery myocardial bridges (MB) are rare. We report a patient with an unusual coronary bridge, a left circumflex coronary artery bridge, who presented with exercise-induced angina pectoris that was relieved with medical therapy.

Angina Pectoris↗

Pacemaker related endocarditis: analysis of seven cases.

Vegetative electrode infection following permanent pacemaker implantation is a rare and serious complication. Among 1920 patients who underwent permanent pacemaker implantation in our institute between 1980 and 2000, 7 patients aged 65 to 78 years were diagnosed to have pacemaker related endocarditis. In this study, the clinical course and management strategies for these patients are reviewed. The most frequently encountered factors contributing to development of pacemaker infection were local complications such as postoperative hematoma and inflammation, and recurrent surgical interventions on the pacemaker system. In blood cultures S. aureus was the most common causative microorganism. Echocardiography could be performed in 5 patients. Three patients were referred to open-heart surgery for total removal of the pacemaker system, and one patient had his pacemaker system removed percutaneously. The remaining 3 patients did not agree to either surgical or percutaneous removal. These patients have been under antibiotic therapy for approximately 3 years and they still do not have any signs of a serious infection. Consequently, in patients with permanent pacemakers, infective endocarditis should be considered in the presence of fever and local symptoms. Blood cultures should be obtained and echocardiography should be performed. Complete removal of the pacemaker system with intensive antibiotic treatment is necessary for complete eradication of the infection. However, if percutaneous or surgical removal of the electrodes cannot be done because of high perioperative risk or the patient does not agree to undergo either method, medical treatment with long term antibiotic use may be considered as an alternative.

Aged↗

Long-term follow-up of pacemakers with an Autocapture pacing system.

UNLABELLED: The aim of this study was to evaluate the safety and performance of the Autocapture pacing system during a 5-year follow-up period. The study was conducted retrospectively between May 1996 and May 2001. Sixty consecutive patients who had undergone VVI pacemaker implantation using an Autocapture program with leads 1402T (n: 31) and 1452T (n: 29) were included in the study. Intraoperative measurements including a ventricular stimulation threshold test, sensing of intrinsic R wave (mV), and lead impedance (W) were done by a standard pacing system analyzer. Evoked responses (ER, mV) and polarization signals (PS, mV) were measured after the pocket was closed. Pacing thresholds by Autocapture (AC thrd, V) and Vario (Vario thrd, V), battery current (mA), and battery impedance (kW) were also repeated during predischarge and 1, 6, 12, 18, 24, 30, 40, 50, and 60 months after discharge. According to the ER and PS values an Autocapture algorithm could be activated in 49 patients (88%). The Autocapture algorithm remained active during the follow-up in all of these patients. In patients with inappropriate ER and PS values (11 patients, 12%), pacemakers were programmed to a VVIR pacing mode and Autocapture algorithm was inactivated. ER and PS values did not reach appropriate values to activate the Autocapture algorithm in any of these patients in consecutive follow-ups. Twenty-four-hour Holter monitoring could be conducted in 32 patients (53%). In all recordings, when the loss of capture occurred, it was confirmed that back-up pacing continued. When the first measurements recorded during implantation were compared to approximately the 5th year measurements; ER (9.2 mV vs 9.6 mV), PS signal (1.13 +/- 0.30 mV vs 1.15 +/- 0.72 mV), AC thrd (0.4 V vs 1.2 V), Vario thrd (0.7 V vs 1.3 V), and lead impedance (502 ohm vs 620 ohm) were not changed significantly. Battery impedance increased 1 kOhm between 30-40 months of the implantation. Seven deaths occurred during follow-up. Three patients had fatal myocardial infarction, one died due to a non-cardiac event, and the remaining three died due to progressive heart failure. CONCLUSION: ER, R wave amplitude, and PS, which are the main parameters for the continuation of Autocapture function, did not change significantly during long-term follow-up. High output back up pacing provided additional safety for sudden rises in threshold. The Autocapture pacing algorithm was found to be effective and reliable during long-term follow-up.

Aged↗

Tricuspid valve perforation by permanent pacemaker lead--a case report.

Tricuspid valve perforation with pacemaker lead is one of the extremely rare complications of transvenous pacemaker implantation. Approximately all reported cases have been diagnosed at autopsy. The authors present a case of tricuspid valve perforation caused by pacemaker lead that was diagnosed during cardiac surgery and treated successfully by removing the lead and suturing the tricuspid valve.

Aged↗

An electrocardiographic algorithm for determining the location of pacemaker electrode in patients with right bundle branch block configuration during permanent ventricular pacing.

The expected morphology of right ventricular pacing is a left bundle branch block (LBBB) pattern. However, right bundle branch block (RBBB) can also be seen during permanent right ventricular pacing. The aim of this study was to develop an electrocardiographic algorithm to differentiate this benign condition from septal and free wall perforation with subsequent left ventricular pacing. Three hundred consecutive patients who had permanent ventricular or dual-chamber pacemaker implantation between 1999 and 2000 were screened and 25 patients (8.3%) who exhibited RBBB configuration were included in the study. Echocardiograms and chest radiographs were evaluated in order to identify the pacing lead location in this group. The authors formed a study group with their own 25 patients and 22 cases of RBBB with permanent pacemaker from previous publications (total 47 patients). Frontal axis, QRS morphology in lead V(1), and the precordial transition point, which is defined as the precordial lead where R wave amplitude is equal to S wave amplitude, were examined. Placement of precordial leads V(1) and V(2) 1 interspace lower than the standard location (Klein maneuver) eliminated the RBBB pattern in 12 patients. RBBB pattern with "true right ventricular pacing" was detected in 24 of the 25 patients, and in 11 of the 22 patients reported in the literature (total 35 patients). Right ventricular pacing was correctly identified in 34 of 35 patients with use of criteria including left superior axis deviation, RS or qR morphology in lead V(1), and precordial transition at lead V(3) with a high sensitivity and specificity. A simple surface electrocardiogram can accurately predict the lead location in patients having RBBB morphology with right ventricular pacing.

Bundle-Branch Block↗