PubMed Health⌕ Search

Biomedical subjects

J A Awad

Publications and source records attributed to J A Awad.

At least 55 records · Page 3Linked to original sources

Expanded PTFE prostheses as arterial substitutes in humans: late pathological findings in 73 excised grafts.

Through collaboration of surgeons, pathologists and bioengineers at five centers in Canada and France, this study analyzed the late pathology and structural changes in 73 expanded PTFE arterial prostheses harvested from patients at autopsies and reoperations. The degree of tissue encapsulation increased with the duration of implantation but was reduced by the presence of infection. In several cases, the fibrous tissue penetrated the wall of the prosthesis and partitioned off the thin outer layer, thus disrupting the delicate microporous structure of the wall. The presence of aneurysms was observed in models that had no external reinforcing layer and among grafts that apparently suffered from surgical trauma. Wrinkling of grafts was noted at areas of flexion and was often associated with thickening of the external capsule and reduced luminal diameters. Endothelialization was found within only a few millimeters of the anastomoses. The luminal surfaces were generally not well healed. The PTFE structure was usually readily visible under a thin covering of loosely adhering thrombotic deposits. Bacteria were observed in 46% of the cases, even though only 29% were considered clinically infected. The incidence of lipid or cholesterol deposits was high. Avoiding iatrogenic trauma to the external wall of the prosthesis during implantation is important. Those features where design improvements are required to provide longer term structural integrity and dimensional stability in future models of expanded PTFE prostheses should be identified.

Adult↗

Thrombus formation in a staged capillary membrane oxygenator associated with a microaggregate blood filter: a scanning electron microscope study.

Blood contact at interfaces in extracorporeal devices is a source of traumas. Proteins are very rapidly adsorbed; then, depending on which proteins are left various degrees of platelet aggregation follow and thrombi develop. The scanning electron microscope reveals very instructive information on the morphology of the blood deposits which adhere to foreign surfaces. Oxygenators such as the Awad D, which is a staged one made of silicone rubber, become "thrombus invaded" after prolonged extracorporeal circulation in spite of adequate heparinization of the blood. In most cases, evaluation of membranes and devices is assessed with respect to transfer of blood gases. Careful examination of the morphology of deposits should be developed. This study shows the importance of blood flow rate, design, and materials.

Animals↗

Thrombus formation and microaggregate removal during prolonged extracorporeal circulation using a capillary membrane oxygenator. A scanning electron microscope study.

Despite adequate heparinization, thrombus formation occurs at the blood/foreign material interface. Depending on the part of the device, the material and the blood flow, the amount and the components of thrombi vary greatly. This is not dangerous by itself but clots can be expelled downstream and damage the lungs, brain, kidney and retina. Interposition of a filter may prevent risks of embolization. The present paper reports the scanning electron microscope study carried out on the Awad oxygenator after use during prolonged extracorporeal circulation on 13 dogs. No filter has been inserted in the circuit for the first six experiments. A screen filter (4) or a polyurethane foam filter (3) was employed in the following ones.

Animals↗

Preclotting and thrombosis of a dacron prosthesis. A scanning electron microscope study.

The authors report eht study of preclotting made on a knitted Dacron prostheses before implantation into a patient. Within 24 h of implantation, clotting occurred. The patient had to be reoperated, and a second preclotting followed. Specimens were removed at different times and fixed in a Rembaum solution before being dried and studied by scanning electron microscopy.

Aged↗

Nature of deposits in a tubular membrane oxygenator after prolonged extracorporeal circulation: a scanning electron microscope study.

Although silicone fibers are among the most compatible with tissue and blood, numerous deposits are observed after their prolonged usage in a capillary membrane oxygenator, even when the blood has been properly heparinized. The scanning electron microscope (SEM) study shows that the morphology of these deposits varies greatly, depending upon the part of the unit from which the sample is taken. The area close to the inlet is the most severely affected. The outlet zone is affected to a lesser degree, and the areas in between are only slightly affected.

Animals↗