PubMed Health⌕ Search

Biomedical subjects

J A Deprest

Publications and source records attributed to J A Deprest.

At least 19 recordsLinked to original sources

Bipolar coagulation of the umbilical cord in complicated monochorionic twin pregnancy.

OBJECTIVES: In monochorionic twin pregnancy in which one twin is a nonviable fetus, selective feticide may be considered. We aimed to occlude the umbilical cord with a bipolar forceps for doing so. STUDY DESIGN: This was a multicenter experience in 10 consecutive patients either with twin-to-twin transfusion syndrome and one fetus affected by a condition not compatible with normal extrauterine life or with acardiac twinning. RESULTS: There were no intraoperative problems, and the mean procedure time was 17.5 minutes. The flow was stopped in all 10 cases. Two cases were complicated by rupture of the fetal membranes within 2 days, and the pregnancies were terminated. The other 8 pregnancies resulted in the live birth of a healthy baby. The mean interval between procedure and birth was 15.1 weeks (range, 7-20 weeks). In one patient emergency cesarean delivery for abruptio placentae was done at 26 weeks, 7 weeks after the procedure. The other 7 patients were delivered beyond the 36th week of gestation. All 8 children are alive and well, with a mean follow-up of at least 1 year. CONCLUSION: Bipolar coagulation is a safe, effective, and simple procedure for cord coagulation that is feasible through a single port and can be performed solely under ultrasonographic guidance.

Female↗

Successful sealing of fetoscopic access sites with collagen plugs in the rabbit model.

OBJECTIVE: The aim of this study was to evaluate the efficacies of various plugging techniques in sealing the membrane defect created by fetoscopy in the rabbit at midgestation. STUDY DESIGN: Fetoscopy was performed in pregnant rabbits at 23 days' gestation (term, 32 days' gestation). In group 1 fetal sacs were left unclosed (positive control group, n = 24). In group 2 injection with commercially available extracellular matrix (Matrigel; BD Labware, Bedford, Mass) was performed and a myometrial suture was inserted (n = 23). In group 3 the entry site was plugged with collagen (Colgen; Inter-Phar, Paris, France) combined with a myometrial suture (n = 22). At 30 days' gestation the membrane integrity, amniotic fluid presence, and fetal lung/body weight ratios were assessed. The plugging site was examined histologically. RESULTS: The use of suture and collagen plugs (group 3) resulted in functional restoration of membrane integrity with preservation of amniotic fluid and normal fetal lung/body weight ratio at term in 82% of cases, compared with 42% in the positive control group (group 1; P <.05). Histologic examination revealed entrapment of membranes between the plug and the myometrium but no anatomic repair of the membranes. The use of suture and extracellular matrix (group 2) did not achieve better results than those seen in group 1 (positive control group). CONCLUSION: Collagen plugs achieved functional sealing of fetoscopic access sites in a rabbit model and prevented oligohydramnios and pulmonary hypoplasia.

Amnion↗

Is the angle of needle insertion influencing the created defect in human fetal membranes? Evaluation of the agreement between specialists' opinions and ex vivo observations.

OBJECTIVE: We sought to evaluate the agreement between the opinions of specialists in fetal medicine with ex vivo observations on the potential influence of the angle of needle insertion on the fluid leak through the created defect in human fetal membranes. STUDY DESIGN: Membranes from placentas of women who were delivered by elective cesarean were harvested, cut in pieces, and secured to the bottom of plastic tubes filled with Hartmann solution. They were punctured with 18-, 20-, or 22-gauge needles, with an angle of insertion of 90 degrees (group 1) or 45 degrees (group 2), and the flow rate (in milliliters per minute) through the created defect at a constant pressure of 150 mm H(2)O was measured. Fifty physicians performing amniocentesis at fetal medicine reference centers were interviewed about their impression and clinical attitude with respect to the angle of needle insertion at the time of amniocentesis. RESULTS: In the ex vivo study, puncture with a 45 degrees angle was associated with a significantly lower flow of fluid through the membrane defect for all needle sizes tested. Regarding survey answers, 82% of physicians try to perform amniocentesis with a given angle (ie, 90 degrees in the vast majority of cases). Among the reasons for doing so, minimizing membrane damage was mentioned in more than half of cases. CONCLUSION: These results provide evidence that the angle of needle insertion influences the type of defect and therefore the flow rate through human membranes. Membrane damage is a concern of a proportion of specialists while performing amniocentesis, but ex vivo observations do not agree with clinical assumptions on the potential influence of the angle of insertion.

Amniocentesis↗

Controlled balloon dilatation for laparoscopic extraperitoneal bladder neck suspension in patients with previous abdominal surgery.

PURPOSE: The balloon dilator is used in a variety of minimally invasive preperitoneal and retroperitoneal operations. In this study, we compared the ability to create an extraperitoneal cavity using a balloon spacer in patients with and without previous abdominal surgery undergoing laparoscopic bladder neck suspension. PATIENTS AND METHODS: This prospective study included 38 patients in total, 15 of whom had had previous abdominal wall surgery and 23 who had not. A balloon spacer technique was used to develop the extraperitoneal space. RESULTS: In 80% of the patients with previous surgery, the introduction of the balloon spacer was recorded as simple; in 20%, it was considered difficult. In 78% of the patients without previous surgery, the introduction of the balloon spacer was recorded as simple, in 17% it was difficult, and in 4% it failed. In 80% of the patients with previous surgery, the extraperitoneal view was good or acceptable, in 20% it was poor, and in 13% it failed. In 92% of the patients without previous surgery, the extraperitoneal view was good or acceptable, in 4% it was poor, and in 4% dilatation failed. Morbidity was equally divided between the groups. CONCLUSIONS: Previous abdominal surgery is not a contraindication to laparoscopic extraperitoneal surgery using a balloon spacer. The approach carries low morbidity, similar to that in patients without previous abdominal surgery.

Abdomen↗

Matrix metalloproteinases -2 and -9 and their endogenous tissue inhibitors in fetal membrane repair following fetoscopy in a rabbit model.

The cellular mechanisms underlying fetal membrane repair are poorly understood. Matrix metalloproteinases (MMP) and the endogenous tissue inhibitors of metalloproteinases (TIMP) play a key role in the control of turnover of extracellular matrix in fetal membranes at normal parturition and preterm prelabour rupture of the fetal membranes (PPROM). The time course of secretion of MMP-2 (72 kDa, gelatinase A) and MMP-9 (92 kDa, gelatinase B) and TIMP into extra-embryonic coelomic, allantoic and amniotic fluids in a rabbit model was examined. Furthermore, to evaluate their role in fetal membrane repair, the changes induced by fetoscopy at mid-gestation (23 days; gestation length is 32 days) were investigated. Zymography showed predominantly secretion of latent MMP-2 at 18, 23 and 30 days of gestation in all gestational compartments. Reverse zymography detected a broad range of TIMP activity with molecular weights of 27-30 kDa (TIMP-1, glycosylated TIMP-3 and TIMP-4), 24 kDa (unglycosylated TIMP-3) and 21 kDa (TIMP-2). Following fetoscopy, both MMP-2 and TIMP increased significantly in amniotic fluid and extra-embryonic coelomic fluid, but not in allantoic fluid, as demonstrated by densitometric analyses. These findings indicate a modulating role for MMP and TIMP in the repair processes following a surgically induced fetal membrane defect.

Animals↗

Time-related cotyledonary effects of laser coagulation of superficial chorionic vessels in an ovine model.

Endoscopic Nd:YAG laser coagulation of superficial chorionic plate vessels has been suggested as a 'causal' therapy for severe twin-to-twin transfusion syndrome (TTS), as it is believed to arrest flow over vascular anastomoses. The therapy remains debated, partly because it is questioned whether coagulation of superficial chorionic vessels can arrest blood flow over deeply located anastomoses. The latter are believed to be responsible for the majority of cases of severe TTs. In this study, the coagulation performance, and the immediate and delayed tissue effects of laser coagulation were evaluated in an in vivo ovine model. Eight pregnant ewes of about 100 days' gestational age (term= 145 days) were studied. In utero coagulation was done through a 1.2 mm fetoscope loaded with a 600 microm laser fibre, connected to an Nd:YAG laser in continuous mode. Superficial cotyledonary vessels were coagulated under visual control at a distance of 1 cm with a mean power of 60 watts. 31 lasered cotyledons were harvested, either immediately (n= 15), 14 days (n = 8) or 42 days (n = 8) after the surgery and evaluated by inspection and histology. Control cotyledons were either neighbouring cotyledons from the same amniotic sac (internal control) or cotyledons from another gestational-age-matched sac (external control). Immediate effects consisted of localized coagulation necrosis at the zone of laser impact with no significant histological effect at more than 2 mm distance, except tissue congestion. Long-term effects consisted of fibrosis without any vascular recanalization or tissue regeneration extending from the impact site over the whole cotyledon. All treated cotyledons underwent complete infarction over time. This study provides experimental evidence supporting that laser coagulation of superficial chorionic vessels entering a cotyledon achieves complete functional elimination of the involved cotyledon.

Animals↗

Gelatin sponge plug to seal fetoscopy port sites: technique in ovine and primate models.

Amniotic fluid leakage and rupture of membranes are common complications of fetoscopy. We describe a plug technique for leakproof removal of endoscopic cannulas. Thirty gelatin sponge plugs were introduced in 5 pregnant ewes and 5 pregnant rhesus monkeys. In the primate model no evidence of amniorrhexis was noted on postoperative ultrasonography. Myometrium and membranes at the port sites were intact at term. A gelatin sponge plug technique may facilitate leakproof port removal after fetoscopy.

Amniotic Fluid↗

The midgestational rabbit as a model for the creation of membrane defects after needle fetoscopy.

OBJECTIVES: The aim of the study was to determine whether the pregnant rabbit at mid gestation could be used as a suitable in vivo model for the study of membrane defects after invasive procedures. STUDY DESIGN: Pregnant rabbits at gestational ages of 22 and 18 days (term is 32 days' gestation) underwent needle insertion with different instrument diameters (1.1 mm, 1.35 mm, 2.0 mm, and 2.7 mm). Two different insertion techniques were evaluated, blind amniotic puncture and puncture through surgically exposed amnion. Membrane integrity, presence of amniotic fluid, and fetal lung/body weight ratio were evaluated at 31 days' gestation. RESULTS: Among rabbits operated on at 22 days' gestation the amniotic integrity restoration at 31 days' gestation ranged from 46% to 76% in the different diameter and access technique groups, as compared with 98% in untreated sacs (P <.05 for all groups). Fetuses from sacs with persisting membrane defects had oligohydramnios and significantly lower fetal lung/body weight ratios. Survival rates among fetuses operated on at 18 days' gestation were so poor that appropriate statistical analysis was not possible in this group. CONCLUSIONS: The rabbit at mid gestation can be used as a model to reproduce permanent membrane defects after fetoscopy, reproducing oligohydramnios and pulmonary hypoplasia. This may provide a suitable in vivo model for the study of iatrogenic membrane defects.

Amnion↗

Natural protective mechanisms against endoscopic white-light injury in the fetal lamb eye.

OBJECTIVE: To evaluate light transmission, possible light trauma, and techniques for protection of the fetal eyes during intrauterine videoendoscopic surgery in a sheep model. METHODS: In vitro studies were done at various gestational ages, including spectrometry of light output by a halogen light source and telescope and light transmission by spectrophotometry in the range of 180-3000 nm through amniotic fluid (AF) and fetal eyelids. In vivo electron-microscopic, morphologic analysis of the retinas of 65-, 95-, 108-, and 112-day-old fetal lambs with (n = 8) and without (n = 8) 30 minutes' light exposure to the open eye was also done. RESULTS: The light spectrum at the tip of the telescope was 400-750 nm, with a maximum irradiance of 3x10(-3) W/cm2 at 580 nm. In the ultraviolet spectrum (less than 300 nm), irradiance was less than 0.5x10(-3) W/cm2. Light transmission through ovine AF ranged from 30% at 300 nm to 89% at 700 nm at 84 days' gestation, decreasing to less than 0.01% (300 nm) and 70% (700 nm) at 112 days. Fetal eyelids did not transmit more than 1% of light (any wavelength). After direct in vivo light exposure, no retinal damage was found. Photoreceptors were present from 108 days onward, but chromophores were scant or absent at all ages studied. CONCLUSION: The light spectrum of a standard endoscope is limited to 400-750 nm; ultraviolet light is filtered out. The AF transmits harmful blue light poorly. Fetal eyelids seem to protect the eye by extremely low transmission and light dispersion. Even with the eye open, no morphologic retinal damage was found. The strong light sources used with fetal endoscopy did not appear to pose a threat to the fetal retina.

Animals↗

Closure techniques for fetoscopic access sites in the rabbit at mid-gestation.

Operative fetoscopy may be limited by its relatively high associated risk of preterm prelabour rupture of membranes. The objective of this study was to study closure techniques of the access site for fetoscopy in the mid-gestational rabbit. A total of 32 does (288 amniotic sacs) at 22 days gestational age (GA; term = 32 days) underwent 14 gauge needle fetoscopy, by puncture through surgically exposed amnion. Entry site was randomly allocated to four closure technique groups: myometrial suture (n = 14), fibrin sealant (n = 15), autologous maternal blood plug (n = 13), collagen plug (n = 14); 16 sacs were left unclosed (positive controls), and the unmanipulated 216 sacs were negative controls. Membrane integrity, presence of amniotic fluid and fetal lung to body weight ratio (FLBWR) were evaluated at 31 days GA. Following fetoscopy without an attempt to close the membranes, amniotic integrity was restored in 41% of cases (amniotic integrity in controls 94%; P = 0.00001). When the access site was surgically closed, the amnion resealed in 20-44% of cases, but none of the tested techniques was significantly better than the others or than positive controls. Permanent amniotic disruption was associated with a significantly lower FLBWR in all groups. In conclusion, the rate of fetoscopy-induced permanent membrane defects in this model did not improve by using any of the closure techniques tested here.

Animals↗

Obstetrical endoscopy.

Fetoscopy has been reintroduced in fetal diagnosis and therapy, as a result of instrumental innovations. It has been suggested that fetoscopy be used to guide endoscopic operations on the fetus, but this application is still in the experimental phase. Its use for surgical interventions on the placenta, umbilical cord, and to a lesser extent the fetal membranes, could be called 'obstetrical' endoscopy. Nd:YAG laser coagulation of chorionic plate vessels for feto-fetal transfusion syndrome is the most common operation carried out today. Survival rates of 60% or more have recently been reported on both sides of the Atlantic Ocean. Neurological morbidity does not exceed 6%, which compares favorably with serial amnioreductions and may become the most important incentive for performing the operation. A randomized trial comparing both therapies as a next step is being proposed. Fetoscopy has also been used for cord ligation, but because of the complexity of the operation and the high risk for preterm prelabor rupture of the membranes, other alternatives have been investigated. Most experience has been gathered with bipolar cord occlusion, a procedure which can be performed under ultrasound guidance. The instrumental considerations and potential complications of fetoscopy are discussed.

Female↗

IGF-I, IGF-II, IGF binding protein 1, and C-peptide in second trimester amniotic fluid are dependent on gestational age but do not predict weight at birth.

Previous data suggested that small for gestational age newborns have increased levels of IGF binding protein 1 (IGFBPI) in amniotic fluid (AF) at 15-16 wk of pregnancy. In this study, we developed an RIA for IGFBP1 and measured IGFBP1 concentrations in 209 AF samples with normal fetal karyotype between 14 and 20 wk; we measured IGF-I, IGF-II, and C-peptide in the same samples. Concentrations of these growth-modulating factors were all positively correlated with gestational age at sampling (p < 0.0001). After correcting for gestational age, AF IGFBP1 remained strongly correlated with IGF-I and IGF-II (both p < 0.0001); their concentrations were many times higher in AF than in cord serum during the third trimester. None of the growth-modulating factors in AF correlated with birth weight, after correction for gestational age; birth weight percentile distribution was comparable in two groups of newborns who had AF values of IGF-I, IGF-II, IGFBP1, or C-peptide that were either less than or equal to the 50th percentile or more than the 50th percentile at sampling. However, placenta weight and the placenta weight to birth weight percentage were negatively correlated with AF IGF-I, IGF-II, and IGFBP1; placenta weight to birth weight percentage was lower in pregnancies with IGFBP1 values more than the 50th percentile compared with those less than or equal to the 50th percentile at sampling. In conclusion, AF concentrations of IGFBP 1 increase gradually between 14 and 20 wk gestational age and correlate with IGF-I and IGF-II levels; high IGFBP1 levels do not predict small for gestational age newborns, but are associated with lower placenta weight.

Adult↗

Cord occlusion techniques for selective termination in monochorionic twins.

We wished to determine the optimal method for cord obliteration to perform selective reduction in complicated monochorionic (MC) twin pregnancies under different clinical conditions. For this purpose, we reviewed our experience and the available published literature and unpublished reports. Indications were a cardiac twin pregnancy, twins discordant for fetal anomaly, and severe feto-fetal transfusion syndrome where one twin had a very poor prognosis. Data were available for the following techniques: cord embolization, fetoscopic cord ligation, laser coagulation, monopolar coagulation and bipolar cautery. Unfortunately the data are heterogeneous, incomplete and reports are only sporadic. Cord embolization using coils or sclerosants has a high failure rate and can no longer be recommended. In 23 published cases of fetoscopic cord ligation a failure rate of 10% was reported. After successful ligation an overall fetal survival rate of 71% but a risk of preterm prelabor rupture of the membranes (PPROM) of 30% was documented. Four cases of monopolar coagulation have been published--all in a cardiac twin pregnancies. In three cases the abdominal aorta was coagulated prior to 20 weeks and complete cessation of flow was demonstrated. In 10 cases of bipolar cord coagulation, all procedures were technically successful. Nine of 10 were performed under ultrasound guidance through a single port. In 2 cases, frank PPROM occurred, leading to induction of labor. The other eight fetuses were born at 35 weeks or more. Nd:YAG coagulation of the cord was much more sporadically described; the success of the procedure seems to be clearly dependant on gestational age. In all our attempts prior to 20 weeks, we failed in only one out of 6 cases. In summary, there is little data to perform meaningful comparisons of available techniques for umbilical cord occlusion. Based on practical and technical considerations we use the following clinical algorithm: prior to 21 weeks, we attempt to coagulate the cord with Nd:YAG laser. If this is unsuccessful, or for gestations beyond 21 weeks, bipolar cord coagulation is currently our other method of choice. Sonoendoscopic cord ligation is reserved as backup procedure if neither of these methods are successful.

Congenital Abnormalities↗

[Minimally invasive techniques make fetal surgery possible. Disabling abnormalities can be corrected].

Increases in our knowledge of the fetus and improved skill in early prenatal diagnosis inevitably result in attempts to treat some of the abnormalities detected. Although most fetal malformations diagnosed prenatally in continuing pregnancies are best managed by medical and surgical intervention after planned delivery, some structural defects may require in utero-treatment to forestall subsequent sequelae. The article consists in a review of the current status of ultrasound-guided invasive fetal therapy, including multifetal pregnancy reduction, manipulation of amniotic fluid, drainage and shunting procedures, fetal transfusion therapy, operative fetoscopy, and in utero stem cell transplantation. Future prospects and developments in this rapidly expanding field are also outlined.

Amniocentesis↗

Fetal membrane closure techniques after hysteroamniotomy in the midgestational rabbit model.

OBJECTIVE: We studied closure techniques for amniotic access in midgestational rabbits. STUDY DESIGN: Twenty-eight rabbits with a total of 313 amniotic sacs were used for this study. In each animal a 1 cm hysteroamniotomy was made in two amniotic sacs at 22 days' gestation (term = 32). For 12 amniotic sacs (group 1) only the myometrium was closed by microsurgical suturing. In group 2 (n = 12), sutures included myometrium and membranes. In group 3 (n = 8), a collagen plug was placed, and in group 4 (n = 12) fibrin glue was used. Twelve sacs were left unclosed (positive controls) and the unmanipulated 257 sacs were negative controls. Eight days later (gestational age 30 days) amniotic sacs were evaluated for the presence of amniotic fluid, membrane integrity, and fetal weight and survival. Statistics were done with two-tailed Fisher's exact test and one-way analysis of variance. RESULTS: Membrane integrity (p = 0.0036) and amniotic fluid (p = 0.047) were best restored after myometrial closure. Fetal weight and survival rate were not affected by different closure techniques. CONCLUSION: In this model primary closure of the myometrium only yielded best results.

Amnion↗

The plug-unplug sequence: an important step to achieve type II pneumocyte maturation in the fetal lamb model.

PURPOSE: The purpose of this study was to test the hypothesis that tracheal obstruction (plugging) in the fetal lamb model leads to a decrease in the absolute number of type II pneumocytes and that reversing the obstruction before birth (unplugging), allows the type II cells to recover while maintaining the beneficial effect on lung growth. METHODS: Nine time-dated pregnant ewes (term, 145 days), carrying 17 fetuses, were used in this surgical trial. The fetuses were divided into three experimental groups: group A underwent plugging at 93 days gestation, followed by unplugging at 110 days; group B animals had tracheal ligation at 93 days and group C consisted of unoperated controls. All fetuses were delivered by cesarean section at 136 days' gestation. The fetal trachea was obstructed with the tracheoscopically placed detachable balloon described by our group. Unplugging was performed by needle puncture of the balloon under tracheoscopic vision. Outcome measurements consisted of lung-to-body-weight ratio (LWBR), lung morphometry (mean terminal bronchial density [MTBD] and linear intercept [Lm]), and assessment of the number of type II pneumocytes. The latter was determined by in situ hybridization to the mRNA of surfactant protein-C, which is exclusively produced by type II cells. Statistics were calculated using a two-tailed unpaired t test and P less than .05 is considered significant. RESULTS: Seventeen animals are included in the results. All of them had lung samples analyzed for lung morphometry, whereas for type II cells analysis, three animals were studied in each group. Morphometric analyses were consistent with pulmonary hyperplasia for group B, whereas group A lungs showed more histological maturity than group C albeit not as marked as group B. In group A, there was a similar number of type II cells to that observed in group C (53.2 +/- 3.9 v 55.9 +/- 4.0, P = .66). However, for group B animals, the number of type II pneumocytes was markedly decreased compared with controls (4.7 +/- 0.1 v 55.9 +/- 4, P = .0003). CONCLUSIONS: The authors conclude that tracheal ligation until birth, although inducing pulmonary hyperplasia, significantly decreases the number of type II pneumocytes in the alveoli. After a temporary 15-day occlusion initiated at 95 days' gestation, there is complete normalization of the density of type II cells. These results bear importance on the duration of PLUG to treat the pulmonary hypoplasia seen in congenital diaphragmatic hernia. Temporary tracheal obstruction now needs to be tested in a hypoplastic lung model.

Animals↗

Single-port tracheoscopic surgery in the fetal lamb.

BACKGROUND/PURPOSE: Endoscopic fetal surgery could help avoid many of the problems associated with open fetal surgery, but the use of multiple ports may be too traumatic to the membranes. The authors describe a single-port technique of tracheoscopic surgery in the fetus. METHODS: Time-dated pregnant ewes (95 to 105 days; term, 145 days) underwent midline laparotomy under general halothane anesthesia. A 5-mm-diameter balloon-tipped cannula was introduced in the uterus by Seldinger technique. A 1.2-mm semirigid mini-endoscope, fitted inside a 9F, 20 degrees curved sheath, was introduced under continuous, low-pressure irrigation, inside the fetus' mouth, and advanced into the trachea. RESULTS: Endotracheal procedures, including temporary (n = 11) and permanent balloon tracheal occlusion (n = 30) and placement of a barbed guide wire for endotracheal occlusion device insertion (n = 12), were performed by introducing a 1-mm diameter instrument alongside the telescope. These were successfully performed in 52 of the 53 fetuses. The rigidity of the telescope allowed controlled access to the pharynx; its curve allowed full tracheobronchial endoscopy with the fetus in utero. CONCLUSIONS: The present technique marries the control and optical quality of a rigid endoscope with the physiological curve only a flexible instrument could offer until now. The types of procedures performed with this technique illustrate its potential as a research tool; the size (1.2-mm diameter), shape, and optical qualities of the telescope should make clinical applications possible.

Animals↗

Experience with fetoscopic cord ligation.

OBJECTIVE: In the case of a monochorionic multiple pregnancy with one non-viable fetus who compromises its co-twin, fetoscopic cord ligation may be performed. We describe our fetoscopic cord ligation technique and discuss the efficacy of cord ligation for salvaging the co-twin, based on available data. STUDY DESIGN: Descriptive case series of four cases and review of the cases published up to 1996. RESULTS: We performed four successful ligations. Of the 23 reported cases, which include the present series, two ligations failed. Four fetuses died in utero, and 17 were born alive at a mean of 8 weeks following the procedure. Two babies died in the perinatal period, a third after 60 days. Preterm uterine contractions do not seem to be a clinical problem. Preterm prelabour rupture of the membranes (PPROM) complicates about 40% of cases, the majority occurring prior to 32 weeks. CONCLUSION: Fetoscopic cord ligation is a feasible procedure with a 71% survival rate and a high risk for PPROM.

Adult↗