Determination of acetate in biological material by vacuum microdistillation and gas chromatography.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to J A Dowling.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We have developed a gas liquid chromatographic assay for plasma acetate which detects 0.01 mM and has a standard deviation of less than 16% of the mean at 0.05 mM. The acetate concentration of venous blood obtained from normal subjects was 0.025 +/- 0.002 mM. The value was not significantly different from the venous acetate concentration of dialysis patients, prior to a dialysis treatment. The acetate concentration of arterial plasma obtained from dialysis patients prior to a hemodialysis treatment was 0.048 +/- 0.006 mM. This was significantly greater than the venous concentration of 0.027 +/- 0.002 (p less than 0.01). This arteriovenous difference suggests that acetate is utilized peripherally. At the onset of hemodialysis, acetate concentrations rapidly rose and, in all but one case, reached a steady state value in the range of 1.5-5.1 mM. At the termination of dialysis, acetate concentrations fell rapidly, usually achieving baseline values within one hr. The rate of decrease was not a simple logarithmic function, suggesting that acetate metabolism is not solely a first order function. Furthermore, acetate disappearance was more rapid in the dialysis patients than in the normal subjects. We wish to emphasize that the present data, which were obtained on a small number of subjects are preliminary and should be interpreted with caution.