Carotid artery approach for balloon dilation of aortic valve stenosis in the neonate: a preliminary report.

Balloon valvuloplasty in neonates with severe aortic valve stenosis is limited by difficulties in catheter manipulation around the arch and across the valve and by the risk of femoral artery complications. A right common carotid artery cutdown was utilized for balloon aortic valvuloplasty in five neonates 1 to 20 days of age, weighing 3.1 to 3.9 kg. Standard balloon valvuloplasty was performed through a 6F sheath inserted in the right carotid artery. The arteriotomy was repaired at the end of the procedure. Mean left ventricular systolic pressure was reduced from 142 to 97 mm Hg, with a decrease in mean peak systolic pressure gradient from 76 to 33 mm Hg. Only one patient developed mild aortic regurgitation. One patient with a hypoplastic left ventricle died, and one patient required open valvotomy. All four survivors have a normal carotid pulse and no neurologic sequelae. Two of these patients required repeat balloon dilation to treat residual aortic valve stenosis at 8 and 10 months of age, respectively. Balloon valvuloplasty using a carotid artery approach is feasible and was safe in five neonates with severe aortic valve stenosis.

Aortic Valve↗

Diagnostic echocardiographic features of the sinus venosus defect.

To establish the diagnostic criteria for a sinus venosus atrial septal defect cross sectional echocardiograms, cineangiograms, and surgical notes of all patients with this diagnosis seen at the Children's Hospital of Pittsburgh between 1986 and 1988 were reviewed. Seven patients were identified. In each the extent of the atrial septum and the nature of the junction of the superior vena cava with the atria were evaluated echocardiographically from the subcostal position. All had overriding of the superior vena cava and abnormally connected right pulmonary veins. Six patients had undergone cardiac catheterisation and cineangiography. Five patients underwent surgical repair. The operative findings were consistent with the expected morphology in all five, and these features were additionally confirmed in a specimen from the cardiopathological museum. Therefore, the basic anatomical feature of a superior sinus venosus interatrial communication is a biatrial connection of the superior vena cava. This, together with anomalous drainage of the right sided pulmonary veins, results in an interatrial communication outside the confines of the true atrial septum. Overriding of the superior vena cava across the upper rim of the oval fossa is suggested as the pathognomonic diagnostic feature that can clearly be demonstrated echocardiographically from the subcostal position. In essence the lesion is an interatrial communication rather than an atrial septal defect.

Adolescent↗

An evaluation of right and left ventricular function after anatomical correction and intra-atrial repair operations for complete transposition of the great arteries.

Anatomical correction of complete transposition of the great arteries has the potential advantage over intra-atrial repair in that the left ventricle becomes the systemic pump. To investigate the importance of this, we evaluated right and left ventricular function in 21 patients after anatomical correction and in 21 patients after Mustard or Senning operations. First-pass and equilibrium-gated radionuclide angiography were used to measure right and left ventricular ejection fractions between 17 and 78 (mean, 47) months after anatomical correction and between 3 and 187 (mean, 67) months after intra-atrial repair. The mean age of the patient groups at the time of study was 52 and 84 months, respectively. The right ventricular ejection fraction ranged from 35% to 78% (mean, 58%) in patients after anatomical correction and from 27% to 68% (mean, 51%) after intra-atrial repair (p = 0.066). The left ventricular ejection fraction ranged from 39% to 74% (mean, 58%) after anatomical correction and from 35% to 74% (mean, 58%) after intra-atrial repair (p = 0.86). The mean right and left ventricular ejection fractions of both groups were significantly lower than those of normal children. Individuals with systemic ventricular dysfunction were identified after both types of operations; however, symptomatic dysfunction occurred only after intra-atrial repair (p = 0.24).

Cardiac Surgical Procedures↗

Corrected transposition presenting as aortic stenosis in an infant.

Associated intracardiac lesions have been well documented in congenitally corrected transposition. Most often these include ventricular septal defects, dysplasia of the morphologically tricuspid valve and subpulmonic stenosis. Aortic stenosis as the only isolated intracardiac defect in association with corrected transposition has not been described previously. We present such a patient and review the clinical features of corrected transposition.

Aortic Valve↗

A quantitative evaluation of aortic regurgitation after anatomic correction of transposition of the great arteries.

Twenty patients who had undergone anatomic correction of transposition of the great arteries were assessed by Doppler echocardiography or cardiac catheterization, or both, to identify the presence of aortic regurgitation. The severity of aortic regurgitation was evaluated by radionuclide angiographic measurement of the stroke volume index a mean of 47.1 months postoperatively. The stroke volume index was defined as the ratio of the stroke counts between the left and right ventricles. A value greater than 1.8 was considered to indicate significant left ventricular volume overload. Eight patients (40%) were shown to have various degrees of aortic regurgitation by Doppler echocardiography or cardiac catheterization, or both. The mean (+/- SD) stroke volume index was 1.03 +/- 0.15 in these patients and 1.01 +/- 0.21 in the 12 patients without aortic regurgitation (p = NS). The stroke volume index was not above the normal range in any patient, indicating that the degree of aortic regurgitation present was trivial. This medium-term study indicates that trivial or mild aortic regurgitation is a frequent finding after anatomic correction of transposition of the great arteries. However, it rarely results in an audible cardiac murmur or significant left ventricular volume overload. Long-term evaluation is required to determine its importance.

Aortic Valve Insufficiency↗

The pathology of balloon pulmonary valvoplasty.

The pulmonary valve was examined following balloon dilation of pulmonary valve stenosis in six children. Stenosis was due to commissural fusion in two. In these patients, cineangiography showed that the valve was slightly thickened and "domed" during systole. Balloon valvoplasty produced complete separation of fused commissures in one and partial separation in the other. Commissural splitting is likely to be the most common mechanism of relief of pulmonary stenosis by balloon dilation. Incomplete separation could account for the partial reduction of the gradient in most children treated with this technique. Four children had pulmonary valve dysplasia. Balloon valvoplasty did not produce haemodynamic improvement or morphological changes that were identifiable at the time of surgical correction. Tearing of pulmonary valve tissue and avulsion of pulmonary cusps were not seen in this series.

Adolescent↗

Complete heart block as a complication of varicella.

A case of varicella myocarditis complicated by permanent complete heart block requiring treatment with a permanent pacemaker is presented. Antiviral therapy with Acyclovir from the moment of presentation had no effect on the course of the heart block, but may have induced recovery of myocardial contractile dysfunction.

Cardiac Pacing, Artificial↗

The value of counter-current aortography in infants.

Counter-current aortograms were performed on five infants weighing from 1.6 to 2.8 kg. All had symptoms suggestive of congenital heart disease. The images obtained were all of diagnostic quality. In only one, who had anomalous origin of the subclavian artery on the side chosen for the injection, was the diagnosis not made by this technique. No complications directly attributable to the procedure occurred. Counter-current aortography is a safe and effective minimally invasive method of elucidating the anatomy of the aortic arch in young infants.

Aortic Coarctation↗

Pulmonary regurgitation in transposition of the great arteries.

A female infant who presented with cyanosis and tachypnoea was found to have transposition of the great arteries, a ductus arteriosus, and a ventricular septal defect. An aortogram showed evidence of mild pulmonary regurgitation, which persisted after a Senning's operation; this is a hitherto unrecognised clinical finding.

Cardiac Catheterization↗

Balloon aortoplasty for recoarctation following the subclavian flap operation.

Transluminal balloon aortoplasty was successfully performed 7 times in 5 children between 3 and 14 months of age who had had the subclavian flap operation for coarctation of the aorta in the neonatal period. In two the balloon aortoplasty was performed twice. All recoarctations presented with upper limp hypertension and marked upper to lower limb pressure gradients. The pressure gradient decreased immediately after the procedure from 57.1 +/- 13.8 mm Hg to 17.9 +/- 15.5 mm Hg, P less than 0.001. The diameter of the recoarcted region increased from 2.67 +/- 1.0 mm to 3.85 +/- 1.23 mm, P less than 0.05. There were no complications attributable to the dilatation technique. Intermediate term success was unpredictable from the initial results or the angiographic appearance of the recoarctation. Follow-up has been for an average of 12.7 months (range 2-30 months). Four patients have pressure gradients from upper to lower limbs of 20 mm Hg or less. In one this has been achieved by repeat balloon aortoplasty. Severe restenosis has occurred in one other patient despite repeating the angioplasty. The procedure is safe and although intermediate term success cannot be predicted in all cases, we propose that balloon aortoplasty be the initial treatment of choice for recoarctation of the aorta. The place of repeating the procedure when early restenosis occurs has yet to be defined.

Angioplasty, Balloon↗

Double aortic arch associated with coarctation.

An unusual combination of double aortic arch with coarctation of one of its limbs is described. We emphasize the importance of preoperative aortography to demonstrate or exclude coarctation which is clinically silent prior to surgery. This rare association will determine the surgical approach.

Aorta, Thoracic↗

Influence of stenotic valve geometry on measured pressure gradients and ventricular work: the relationship between morphology and flow.

The physiologic impact of aortic valve stenosis is most directly reflected by an increased workload placed on the ventricle. In the pediatric population the morphology of aortic stenosis varies considerably. Fluid dynamic principles suggest that different morphologies may require the ventricle to accelerate blood to different maximal velocities for constant cardiac outputs and valve areas, resulting in different ventricular workloads. This study examined this important concept in in vitro models designed to isolate the effect of valve geometry on distal velocity, pressure gradients, and proximal work. Four stenotic valve morphologies were examined using a variable-voltage pump system. For constant orifice areas and flows, markedly different workloads were required by the pump, and this difference was reflected in direct measurements of pressure gradient and Doppler predictions of gradient. These fundamental fluid dynamic studies isolate the relationship between flow, work, and stenotic valve morphology. Different orifice geometries affect the value of the coefficient of contraction, which is reflected in different maximum velocity values for stenosis with constant anatomic areas and flows. The proximal pumping chamber must generate different levels of force to achieve these different velocities, and this variability is reflected in the clinically measured pressure gradient.

Aortic Valve↗

Intrapericardial left atrial aneurysm: noninvasive diagnosis.

Intrapericardial aneurysm of the left atrium is a rare cardiac anomaly. We present a 10-year-old girl in whom the diagnosis was made following referral for an abnormal configuration of the left heart border seen on chest radiography. Diagnosis was made by echocardiography, but magnetic resonance imaging defined the exact morphology and the relation to adjacent structures. Surgical removal of this aneurysm is recommended because of potentially serious complications.

Child↗