PubMed Health⌕ Search

Biomedical subjects

J A Fessler

Publications and source records attributed to J A Fessler.

16 recordsLinked to original sources

A feasibility study of mutual information based setup error estimation for radiotherapy.

We have investigated a fully automatic setup error estimation method that aligns DRRs (digitally reconstructed radiographs) from a three-dimensional planning computed tomography image onto two-dimensional radiographs that are acquired in a treatment room. We have chosen a MI (mutual information)-based image registration method, hoping for robustness to intensity differences between the DRRs and the radiographs. The MI-based estimator is fully automatic since it is based on the image intensity values without segmentation. Using 10 repeated scans of an anthropomorphic chest phantom in one position and two single scans in two different positions, we evaluated the performance of the proposed method and a correlation-based method against the setup error determined by fiducial marker-based method. The mean differences between the proposed method and the fiducial marker-based method were smaller than 1 mm for translational parameters and 0.8 degree for rotational parameters. The standard deviations of estimates from the proposed method due to detector noise were smaller than 0.3 mm and 0.07 degree for the translational parameters and rotational parameters, respectively.

Algorithms↗

Tomographic reconstruction of tracer gas concentration profiles in a room with the use of a single OP-FTIR and two iterative algorithms: ART and PWLS.

Computed tomographic (CT) reconstructions of air contaminant concentration fields were conducted in a room-sized chamber employing a single open-path Fourier transform infrared (OP-FTIR) instrument and a combination of 52 flat mirrors and 4 retroreflectors. A total of 56 beam path data were repeatedly collected for around 1 hr while maintaining a stable concentration gradient. The plane of the room was divided into 195 pixels (13 x 15) for reconstruction. The algebraic reconstruction technique (ART) failed to reconstruct the original concentration gradient patterns for most cases. These poor results were caused by the "highly underdetermined condition" in which the number of unknown values (156 pixels) exceeds that of known data (56 path integral concentrations) in the experimental setting. A new CT algorithm, called the penalized weighted least-squares (PWLS), was applied to remedy this condition. The peak locations were correctly positioned in the PWLS-CT reconstructions. A notable feature of the PWLS-CT reconstructions was a significant reduction of highly irregular noise peaks found in the ART-CT reconstructions. However, the peak heights were slightly reduced in the PWLS-CT reconstructions due to the nature of the PWLS algorithm. PWLS could converge on the original concentration gradient even when a fairly high error was embedded into some experimentally measured path integral concentrations. It was also found in the simulation tests that the PWLS algorithm was very robust with respect to random errors in the path integral concentrations. This beam geometry and the use of a single OP-FTIR scanning system, in combination with the PWLS algorithm, is a system applicable to both environmental and industrial settings.

Air Pollution, Indoor↗

Mean and variance of single photon counting with deadtime.

The statistics of photon counting by systems affected by deadtime are potentially important for statistical image reconstruction methods. We present a new way of analysing the moments of the counting process for a counter system affected by various models of deadtime related to PET and SPECT imaging. We derive simple and exact expressions for the first and second moments of the number of recorded events under various models. From our mean expression for a SPECT deadtime model, we derive a simple estimator for the actual intensity of the underlying Poisson process; simulations show that our estimator is unbiased even for extremely high count rates. From this analysis, we study the suitability of the Poisson statistical model assumed in most statistical image reconstruction algorithms. For systems containing 'modules' with several detector elements, where each element can cause deadtime losses for the entire module, such as block PET detectors or Anger cameras, the Poisson statistical model appears to be adequate even in the presence of deadtime losses.

Algorithms↗

Regularization for uniform spatial resolution properties in penalized-likelihood image reconstruction.

Traditional space-invariant regularization methods in tomographic image reconstruction using penalized-likelihood estimators produce images with nonuniform spatial resolution properties. The local point spread functions that quantify the smoothing properties of such estimators are space-variant, asymmetric, and object-dependent even for space-invariant imaging systems. We propose a new quadratic regularization scheme for tomographic imaging systems that yields increased spatial uniformity and is motivated by the least-squares fitting of a parameterized local impulse response to a desired global response. We have developed computationally efficient methods for PET systems with shift-invariant geometric responses. We demonstrate the increased spatial uniformity of this new method versus conventional quadratic regularization schemes in simulated PET thorax scans.

Computer Simulation↗

Maximum-likelihood transmission image reconstruction for overlapping transmission beams.

In many transmission imaging geometries, the transmitted "beams" of photons overlap on the detector, such that a detector element may record photons that originated in different sources or source locations and thus traversed different paths through the object. Examples include systems based on scanning line sources or on multiple parallel rod sources. The overlap of these beams has been disregarded by both conventional analytical reconstruction methods as well as by previous statistical reconstruction methods. We propose a new algorithm for statistical image reconstruction of attenuation maps that explicitly accounts for overlapping beams in transmission scans. The algorithm is guaranteed to monotonically increase the objective function at each iteration. The availability of this algorithm enables the possibility of deliberately increasing the beam overlap so as to increase count rates. Simulated single photon emission tomography transmission scans based on a multiple line source array demonstrate that the proposed method yields improved resolution/noise tradeoffs relative to "conventional" reconstruction algorithms, both statistical and nonstatistical.

Algorithms↗

Ordered subsets algorithms for transmission tomography.

The ordered subsets EM (OSEM) algorithm has enjoyed considerable interest for emission image reconstruction due to its acceleration of the original EM algorithm and ease of programming. The transmission EM reconstruction algorithm converges very slowly and is not used in practice. In this paper, we introduce a simultaneous update algorithm called separable paraboloidal surrogates (SPS) that converges much faster than the transmission EM algorithm. Furthermore, unlike the 'convex algorithm' for transmission tomography, the proposed algorithm is monotonic even with nonzero background counts. We demonstrate that the ordered subsets principle can also be applied to the new SPS algorithm for transmission tomography to accelerate 'convergence', albeit with similar sacrifice of global convergence properties as for OSEM. We implemented and evaluated this ordered subsets transmission (OSTR) algorithm. The results indicate that the OSTR algorithm speeds up the increase in the objective function by roughly the number of subsets in the early iterates when compared to the ordinary SPS algorithm. We compute mean square errors and segmentation errors for different methods and show that OSTR is superior to OSEM applied to the logarithm of the transmission data. However, penalized-likelihood reconstructions yield the best quality images among all other methods tested.

Algorithms↗

Penalized-likelihood estimators and noise analysis for randoms-precorrected PET transmission scans.

This paper analyzes and compares image reconstruction methods based on practical approximations to the exact log likelihood of randoms-precorrected positron emission tomography (PET) measurements. The methods apply to both emission and transmission tomography, however, in this paper we focus on transmission tomography. The results of experimental PET transmission scans and variance approximations demonstrate that the shifted Poisson (SP) method avoids the systematic bias of the conventional data-weighted least squares (WLS) method and leads to significantly lower variance than conventional statistical methods based on the log likelihood of the ordinary Poisson (OP) model. We develop covariance approximations to analyze the propagation of noise from attenuation maps into emission images via the attenuation correction factors (ACF's). Empirical pixel and region variances from real transmission data agree closely with the analytical predictions. Both the approximations and the empirical results show that the performance differences between the OP model and SP model are even larger, when considering noise propagation from the transmission images into the final emission images, than the differences in the attenuation maps themselves.

Image Processing, Computer-Assisted↗

Monotonic algorithms for transmission tomography.

We present a framework for designing fast and monotonic algorithms for transmission tomography penalized-likelihood image reconstruction. The new algorithms are based on paraboloidal surrogate functions for the log likelihood. Due to the form of the log-likelihood function it is possible to find low curvature surrogate functions that guarantee monotonicity. Unlike previous methods, the proposed surrogate functions lead to monotonic algorithms even for the nonconvex log likelihood that arises due to background events, such as scatter and random coincidences. The gradient and the curvature of the likelihood terms are evaluated only once per iteration. Since the problem is simplified at each iteration, the CPU time is less than that of current algorithms which directly minimize the objective, yet the convergence rate is comparable. The simplicity, monotonicity, and speed of the new algorithms are quite attractive. The convergence rates of the algorithms are demonstrated using real and simulated PET transmission scans.

Algorithms↗

Statistical image reconstruction methods for randoms-precorrected PET scans.

Positron emission tomography (PET) measurements are usually precorrected for accidental coincidence events by real-time subtraction of the delayed-window coincidences. Randoms subtraction compensates on average for accidental coincidences but destroys the Poisson statistics. We propose and analyze two new approximations to the exact log-likelihood of the precorrected measurements, one based on a 'shifted Poisson' model, the other based on saddle-point approximations to the measurement of probability mass function (PMF). The methods apply to both emission and transmission tomography; however, in this paper we focus on transmission tomography. We compare the new models to conventional data-weighted least-squares (WLS) and conventional maximum-likelihood methods [based on the ordinary Poisson (OP) model] using simulations and analytic approximations. The results demonstrate that the proposed methods avoid the systematic bias of the WLS method, and lead to significantly lower variance than the conventional OP method. The saddle-point method provides a more accurate approximation to the exact log-likelihood than the WLS, OP and shifted Poisson alternatives. However, the simpler shifted Poisson method yielded comparable bias-variance performance to the saddle-point method in the simulations. The new methods offer improved image reconstruction in PET through more realistic statistical modeling, yet with negligible increase in computation time over the conventional OP method.

Abdomen↗

Preliminary results from intensity-based CT-SPECT fusion in I-131 anti-B1 monoclonal-antibody therapy of lymphoma.

BACKGROUND: In treatment of non-Hodgkin's lymphoma patients with predose-plus-I-131-labeled anti-B1 (anti-CD20) monoclonal antibody, an intratherapy single photon emission computed tomography (SPECT) image is an important part of research estimates of tumor dosimetry. For that imaging, a computed tomography (CT)-SPECT fusion is used both to obtain an attenuation map for the space-alternating generalized expectation maximization reconstruction and to provide CT-based volumes of interest (VoI) to determine activity in tumors and organs. Fusion based on external, skin-surface markers has been used but may not correctly superimpose internal structures. METHODS: A new algorithm, developed and implemented in the Department of Radiology, University of Michigan, and based on the mutual information of grayscale values, was investigated. Results from four anti-B1 therapy patients are presented. RESULTS: In one patient, the new intensity-based fusion provided total reconstructed counts for kidneys that were higher than those produced by marker-based fusion; therefore, the VoI was probably located more accurately. In a second patient, after an acquisition that did not include any skin markers, the new algorithm produced counts/pixel that were similar for four of five tumors consistent with what is expected from an ideal therapy combined with accurate count density estimates. The fifth tumor was quite small and will have its final activity estimate moved toward consistency with the others after a recovery coefficient multiplication. For four tumors in two patients, direct comparison of the two algorithms yielded count totals that were different by no more than 7.2%. CONCLUSIONS: The use of CT-SPECT fusion and subsequent transfer of tumor VoI originally drawn in high-resolution CT space offers potential advantages for quantifying tumor uptake of radioactivity. A new, mutual-information-based fusion algorithm is usable without skin markers. Results indicate that the new fusion algorithm gives equal tumor count values within 7.2% compared with fusion based on external markers. It increases estimates of kidney activity by an average of 6.4%.

Algorithms↗

Grouped-coordinate ascent algorithms for penalized-likelihood transmission image reconstruction.

This paper presents a new class of algorithms for penalized-likelihood reconstruction of attenuation maps from low-count transmission scans. We derive the algorithms by applying to the transmission log-likelihood a version of the convexity technique developed by De Pierro for emission tomography. The new class includes the single-coordinate ascent (SCA) algorithm and Lange's convex algorithm for transmission tomography as special cases. The new grouped-coordinate ascent (GCA) algorithms in the class overcome several limitations associated with previous algorithms. 1) Fewer exponentiations are required than in the transmission maximum likelihood-expectation maximization (ML-EM) algorithm or in the SCA algorithm. 2) The algorithms intrinsically accommodate nonnegativity constraints, unlike many gradient-based methods. 3) The algorithms are easily parallelizable, unlike the SCA algorithm and perhaps line-search algorithms. We show that the GCA algorithms converge faster than the SCA algorithm, even on conventional workstations. An example from a low-count positron emission tomography (PET) transmission scan illustrates the method.

Algorithms↗

Simultaneous transmission/emission myocardial perfusion tomography. Diagnostic accuracy of attenuation-corrected 99mTc-sestamibi single-photon emission computed tomography.

BACKGROUND: The purpose of the present study was to assess the diagnostic performance of attenuation-corrected (AC) stress 99mTc-sestamibi cardiac single-photon emission computed tomography (SPECT) for the identification of coronary heart disease (CHD). METHODS AND RESULTS: With a triple-detector SPECT system with a 241Am transmission line source, simultaneous transmission/emission tomography (TCT/ECT) was performed on 60 patients with angiographic coronary disease and 59 patients with < or = 5% likelihood of CHD. Iteratively reconstructed AC stress 99mTc-sestamibi perfusion images were compared with uncorrected (NC) filtered-backprojection images. Normal database polar maps were constructed from AC and NC images for quantitative analyses. From the low-likelihood patients, the visual and quantitative normalcy rates increased from 0.88 and 0.76 for NC to 0.98 and 0.95 for AC (P < .05). For the detection of CHD, the receiver operating characteristic curves for the AC images demonstrated improved discrimination capacity (P < .05), and sensitivity/specificity values increased from 0.78/0.46 (NC) to 0.84/0.82 (AC) with visual analysis and from 0.84/0.46 (NC) to 0.88/0.82 (AC) with quantitative analysis. For localization of stenosed vessels, visual and quantitative sensitivity values were 0.51 and 0.63 for NC and 0.64 and 0.78 for AC images (P < .05), respectively. CONCLUSIONS: TCT/ECT myocardial perfusion imaging significantly improves the diagnostic accuracy of cardiac SPECT for the detection and localization of CHD. Clinical use of TCT/ECT imaging deserves serious consideration.

Coronary Angiography↗

In vivo mapping of cholinergic terminals in normal aging, Alzheimer's disease, and Parkinson's disease.

To map presynaptic cholinergic terminal densities in normal aging (n = 36), Alzheimer's disease (AD) (n = 22), and Parkinson's disease (PD) (n = 15), we performed single-photon emission computed tomography using [123I]iodobenzovesamicol (IBVM), an in vivo marker of the vesicular acetylcholine transporter. We used coregistered positron emission tomography with [18F]fluorodeoxyglucose for metabolic assessment and coregistered magnetic resonance imaging for atrophy assessment. In controls (age, 22-91 years), cortical IBVM binding declined only 3.7% per decade. In AD, cortical binding correlated inversely with dementia severity. In mild dementia, binding differed according to age of onset, but metabolism did not. With an onset age of less than 65 years, binding was reduced severely throughout the entire cerebral cortex and hippocampus (about 30%), but with an onset age of 65 years or more, binding reductions were restricted to temporal cortex and hippocampus. In PD without dementia, binding was reduced only in parietal and occipital cortex, but demented PD subjects had extensive cortical binding decreases similar to early-onset AD. We conclude that cholinergic neuron integrity can be monitored in living AD and PD patients, and that it is not so devastated in vivo as suggested by postmortem choline acetyltransferase activity (50-80%).

Aged↗

Simultaneous transmission-emission thallium-201 cardiac SPECT: effect of attenuation correction on myocardial tracer distribution.

UNLABELLED: This study evaluates the effect of attenuation correction on regional myocardial tracer distributions defined by 201TI cardiac perfusion SPECT images obtained from healthy volunteers and patients with coronary heart disease. METHODS: A three-detector SPECT system equipped with an 241Am line source and a fanbeam collimator was used for simultaneous transmission/emission (201TI) tomography on 40 patients and 10 normal volunteers. Uncorrected emission images were reconstructed using filtered backprojection (FBP), whereas the attenuation corrected images were iteratively reconstructed with a regularized, least-squares algorithm utilizing the attenuation map computed from the transmission data. Both sets of images were reoriented into short-axis and vertical long-axis slices. Circumferential profile analysis was applied to both datasets of short-axis slices. RESULTS: The normal volunteers demonstrated improved homogeneity in tracer distribution. For a basal short-axis slice, the lateral-to-posterior activity ratio improved from 1.17 +/- 0.12 for FBP to 1.01 +/- 0.07. Basal attenuation appeared properly compensated as the peak basal-to-apical slice activity gradient along the posterior-inferior wall changed from 1.15 +/- 0.12 for FBP to 1.01 +/- 0.09. The apex of the attenuation corrected images showed a significant decrease in activity relative to the base which appeared consistent with anatomic wall thinning. For the inferior and basal septal regions, the defect severity was slightly less in the attenuation corrected images, but the defects were more sharply defined compared to the FBP image defects. CONCLUSION: These results indicate that attenuation correction is clinically feasible and accurately corrects for photon attenuation. Clinical validation, however, is necessary to define the diagnostic benefits.

Coronary Disease↗

In vivo mapping of cholinergic neurons in the human brain using SPECT and IBVM.

UNLABELLED: In the search for an in vivo marker of cholinergic neuronal integrity, we extended to human use the tracer (-)-5-[123I]iodobenzovesamicol (IBVM). METHODS: IBVM, an analog of vesamicol that binds to the acetylcholine transporter on presynaptic vesicles, was prepared with specific activity greater than 1.11 x 10(9) MBq mmole-1. After intravenous injection of [123I]IBVM, body distribution studies (n = 5) and brain SPECT studies (n = 5) were performed on normal human subjects (n = 10). SPECT images of the brain were collected sequentially over the first 4.5 hr following injection, and again 18 hr later. Data were realigned and transformed to stereotaxic coordinates, and localized activities were extracted for tracer kinetic analysis. The cerebral tracer input function was determined from metabolite-corrected radial arterial blood samples. The best data fit was obtained using a three-compartment model, including terms reflecting cerebral blood volume, exchange of free tracer between plasma and brain and specific binding. RESULTS: Dissociation of bound tracer was negligible for up to 4 hr. For the fitted parameters reflecting transport (K1) and binding site density index (k3), coefficients of variation were approximately 8% in cortical regions of interest. Relative distributions corresponded well with postmortem immunohistochemical values reported for the acetylcholine-synthesizing enzyme choline acetyltransferase, k3 (IBVM binding site density index), and tracer activity distribution at 22 hr, but not at 4 hr after injection. CONCLUSION: SPECT imaging of [123I]IBVM succeeds as an in vivo measure of cholinergic neuronal integrity and should be useful for the study of cerebral degenerative processes such as Alzheimer's disease.

Adult↗

Comparison of americium-241 and technetium-99m as transmission sources for attenuation correction of thallium-201 SPECT imaging of the heart.

UNLABELLED: This study compares the ability of 241Am and 99mTc to estimate 201Tl attenuation maps while minimizing the loss in the precision of the emission data. METHODS: A triple-head SPECT system with either an 241Am or 99mTc line source opposite a fan-beam collimator was used to estimate attenuation maps of the thorax of an anthropomorphic phantom. Linear attenuation values at 75 keV for 201Tl were obtained by linear extrapolation of the measured values from 241Am and 99mTc. RESULTS: Lung and soft-tissue estimates from both isotopes showed excellent agreement to within 3% of the measured values for 201Tl. Linear extrapolation did not yield satisfactory estimates for bone from either 241Am (+11.7%) or 99mTc (-15.3%). Patient data were used to estimate the dependence of crosstalk on patient size. Contamination from 201Tl in the transmission window was 5-6 times greater for 241Am compared to 99mTc, while the contamination in the 201Tl data in the transmission-emission detector head (head 1) was 4-5 times greater for 99mTc compared to 241Am. No contamination was detected in the 201Tl emission data of heads 2 and 3 from 241Am, whereas the 99mTc produced a small crosstalk component giving a signal-to-crosstalk ratio near 20:1. Measurements with a fillable chest phantom estimated the mean error introduced into the data from the removal of the crosstalk. CONCLUSION: Based on the measured data, 241Am is a suitable transmission source for simultaneous transmission-emission tomography for 201Tl cardiac studies.

Americium↗