PubMed Health⌕ Search

Biomedical subjects

J A Flint

Publications and source records attributed to J A Flint.

4 recordsLinked to original sources

Magnitude and distribution of acute, self-reported gastrointestinal illness in a Canadian community.

To estimate the magnitude and distribution of self-reported, acute gastrointestinal illness in a Canadian-based population, we conducted a retrospective, cross-sectional telephone survey of approximately 3500 randomly selected residents of the city of Hamilton (Ontario, Canada) from February 2001 to February 2002. The observed monthly prevalence was 10% (95 % CI 9.94-10.14) and the incidence rate was 1.3 (95 % CI 1.1-1.4) episodes per person-year; this is within the range of estimates from other developed countries. The prevalence was higher in females and in those aged < 10 years and 20-24 years. Overall, prevalence peaked in April and October, but a different temporal distribution was observed for those aged < 10 years. Although these data were derived from one community, they demonstrate that the epidemiology of acute gastrointestinal illness in a Canadian-based population is similar to that reported for other developed countries.

Acute Disease↗

Biomimetic finger control by filtering of distributed forelimb pressures.

A linear filter was developed for decoding finger commands from volitional pressures distributed within the residual forelimb. Filter parameters were based on dynamic pressures recorded from the residual limb within its socket, during specific finger commands. A matrix of signal features was derived from eight-dimensional (8-D) pressure vectors, and its pseudoinverse comprised the filter parameters. Results with amputees showed that the filter could discriminate specific finger flexion commands, suggesting that pressure vector decoding (PVD) can provide them with biomimetic finger control.

Adult↗

A biomimetic controller for a multifinger prosthesis.

A novel controller for a multifinger hand prosthesis was developed and tested to measure its accuracy and performance in transducing volitional signals for individual "phantom" fingers. Pneumatic sensors were fabricated from open-cell polymeric foam, and were interposed between the prosthetic socket and superficial extrinsic tendons associated with individual finger flexion. Test subjects were prompted to move individual fingers or combinations thereof to execute either taps or grasps. Sensor outputs were processed by a computer that controlled motions of individual fingers on a mechanical prosthesis. Trials on three upper-limb amputees showed that after brief training sessions, the TAP controller was effective at producing voluntary flexions of individual fingers and grasping motions. Signal energies were between 5 and 25 dB relative to noise from all sources, including adjacent sensors, indicating high degrees of both sensitivity and specificity for tendon-associated transduction. Finger flexions at up to three repetitions per second, and rhythmic tapping of sequential fingers were readily transduced. One amputee subject was able to play a short piano piece with three fingers, at approximately one-quarter normal tempo. TAP sensors responded linearly to graded forces from individual fingers, indicating proportional force control. Our results demonstrate the feasibility of restoring some degree of finger dexterity by noninvasive sensing of extrinsic tendons.

Amputees↗