The safety system for the rotary blood pump, combination of the valve and LVAD pulsatile mode: in vitro test.

The significant amount of regurgitation produced by a stopped rotary blood pump is one of the major considerations for its use as an implantable left ventricular assist device (LVAD), especially if the pump accidentally stops. The installation of a valve is an option for the solution of this potential problem. However, this option may lead to thrombogenic problems, particularly if the valve motion is restricted. This in vitro study analyzes the valve performance and assesses the credibility of a rotary blood pump valve. A pulsatile pump was used as the natural heart and a centrifugal pump as the LVAD. The valve was positioned into the LVAD outflow. In the low speed range (<1,000 rpm in this test condition), normal valve motion was maintained. Also, the valve model provided a higher mean bypass flow than the model without a valve due to reduced regurgitation. However, the valve motion was drastically restricted when in the high speed range (>1,600 rpm in this condition). The pulsatile mode was applied to the LVAD by periodically changing the impeller speed (40 bpm); subsequently, a constant valve motion could be provided. A possibility exists that this pulsatile mode application could eliminate thrombosis formation around the valve. A conclusion was made that the combination of a valve and an LVAD in a pulsatile mode is considered to be a unique safety system for a rotary blood pump.

Blood Pressure↗

Effects of pulsatile flow on gas transfer of membrane oxygenator: MENOX EL-4000 and Gyro C1-E3 pulsatile mode.

It is acknowledged that pulsatile flow enhances the gas exchange performance of membrane oxygenators. However, the data for currently developed oxygenators are limited. In this study, the effect of pulsatile flow was assessed utilizing the MENOX EL-4000 oxygenator. The in vitro test was performed following the Association for the Advancement of Medical Instrumentation (AAMI) standards. Pulsatile flow was produced by the Gyro C1-E3 centrifugal pump with periodical changing of the impeller speed. In Study 1, the following 3 groups were created and examined: nonpulsatile flow, pulsatile flow of 40 bpm, and pulsatile flow of 60 bpm. The blood flow rate was maintained at 3 L/min, and the V/Q ratio was 1. In Study 2, four groups were examined, nonpulsatile flow with V/Q = 1, nonpulsatile with V/Q = 2, pulsatile with V/Q = 1, and pulsatile with V/Q = 2. The blood flow rate was maintained at 4 L/min, and the pulse frequency was set at 40 bpm. In study 1, although O2 transfer was not enhanced, CO2 transfer was significantly improved (40-50%) by pulsatile flow, regardless of pulse frequency. Study 2 demonstrated that pulsatile flow resulted in improved CO2 transfer as did higher ventilation (V/Q = 2). Furthermore, even after applying higher ventilation, the pulsatile mode enhanced CO2 transfer more than the nonpulsatile mode. It was considered that the pulsatile mode induced an active secondary flow and enhanced mixing effects, and consequently CO2 transfer was improved. In conclusion, the pulsatile flow significantly enhanced the CO2 transfer of the MENOX oxygenator. It is indicated that applying the pulsatile mode is a unique and effective method to improve the gas exchange performance for a current membrane oxygenator.

Analysis of Variance↗

Hemolysis test of a centrifugal pump in a pulsatile mode: the effect of pulse rate and RPM variance.

Centrifugal pumps are generally employed as nonpulsatile blood flow pumps; however, these pumps can produce pulsatile flow by periodically alternating the impeller rotation speed. This study investigates blood trauma due to the effect of pulse frequency and various ranges of pump speed. The hemolysis tests were conducted using the Gyro C1E3 pump. The study was divided into the following categories: Group 1 in a nonpulsatile mode; Group 2 operated at 40 bpm with 30% of speed variance; Group 3, 60 bpm with 30% of speed variance; Group 4, 40 bpm with 70% of speed variance; and Group 5, 60 bpm with 70% of speed variance. A flow rate of 3 L/min and a total pressure head of 200 mm Hg were employed in all groups to simulate a percutaneous cardiopulmonary support condition. There were no significant differences in the hemolysis levels among Groups 1, 2, and 3. However, Groups 4 and 5 exhibited a significantly higher hemolysis rate compared to the other groups. These results indicate that a high rate of speed variance increases hemolysis; however, a range of less than 30% does not affect hemolysis. The pulse rate has no significant effect on hemolysis. In conclusion, the higher speed variance increases the hemolysis level when a pulsatile mode is applied with a centrifugal pump at the given test conditions. However, a speed variance of less than 30% or a pulse rate of less than 60 bpm does not affect hemolysis.

Analysis of Variance↗

Estimation of the minimum pump speed to prevent regurgitation in the continuous flow left ventricular assist device: left ventricular drainage versus left atrial drainage.

Due to the fact that centrifugal and axial pumps do not require valves, there is a possibility of back flow when the pump speed is low. To estimate the minimum required pump speed to prevent this regurgitation, an in vitro simulation test was conducted. A pulsatile pump simulated the natural heart while a centrifugal pump simulated the continuous flow left ventricular assist device (LVAD). The LVAD flow was attained from the left atrial (LA) drainage or left ventricular (LV) drainage. The minimum or regurgitate flow was observed in the systolic phase with LA drainage and in the diastolic phase with LV drainage. LV drainage always provided higher flow than LA drainage at the same pump speed. These differences are due to the various total pressure heads of the LVAD. To prevent the regurgitation, the LVAD should maintain a certain pump speed which can create positive flow against the aortic systolic pressure with LA drainage and against the aortic diastolic pressure with LV drainage. These required pump speeds can be identified by the LVAD flow-pressure curve.

Aortic Valve Insufficiency↗

The simple in vitro thrombogenic test: modified methods for same priming pumps.

The improvement of antithrombogenicity is one of the major objectives for the development of blood pumps. Previously we reported that an in vitro thrombogenic test was useful as a pilot study, especially to predict thrombogenic areas. In this study we modified the method for testing pumps with identical priming volumes by eliminating the blood reservoir. Identical compact mock loops (priming volume of 53 ml, without pump) were constructed and tested with the same priming volume of Nikkiso centrifugal pumps, noncoated verus heparin-coated. Two pumps were run simultaneously using the same source of fresh heparinized human blood (activated clotting time [ACT] 150-250 s) for 4 or 6 h. Results indicated that the heparin-coated pump had a longer thrombus free period than the noncoated one. The thrombi location and forms were consistently in the same places the in vivo study had identified. It is suggested that this modified in vitro thrombogenic test is a feasible pilot study, as well as the one previously reported. The minimal priming volume will allow evaluation of multiple pumps simultaneously with the same source blood.

Anticoagulants↗

Development of an atraumatic small centrifugal pump for second-generation cardiopulmonary bypass.

A small and light direct-drive centrifugal pump has been developed for cardiopulmonary bypass. In the development process, blood compatibility studies including a hemolysis study, an in vitro fluid dynamic performance study, and in vivo durability and feasibility studies were performed. The centrifugal pump with a 50 mm diameter impeller resulted in almost the same index of hemolysis value as did a Bio-Medicus centrifugal pump. Heat dissipation from the motor was prevented by using a flexible drive cable. Forty-eight-hour sealing durability around the driving axis was accomplished by using a fluoro-rubber V-ring that connected to the hard chrome-plated stainless steel. In vitro and in vivo performances of the pump were satisfactory. Thrombus formation behind the impeller was prevented by using a holed impeller that generated blood flow from the back to the surface of the impeller. Elimination of air during priming procedures was also easier with this modification. This centrifugal pump has one-quarter of the priming volume, size, and weight of magnetically coupled centrifugal pump systems.

Animals↗

Comparative in vitro encrustation studies of biomaterials in human urine.

A new dynamic in vitro human urine model was developed to compare biomaterial encrustation. The model incorporates a capacity to study seven biomaterials, a daily urine inflow of 500 ml, a reservoir capacity of 700 ml, and a turnover rate of four days. Encrustation studies performed for 2 weeks in sterile and infected (Proteus Vulgaris) urine on segmented polyether polyurethane, polyester polyurethane, silicone (Mitsui), silicone (Dow Corning), biothane, biolor 1 and biolor 11 demonstrated that biolor 11 (silicone-carbon composite) caused the least encrustation. Encrustation analysis showed brushite in the sterile model and struvite and ammonium acid urate in the infected mode I. Biolor II should have beneficial applications in catheters, stents and prosthetics which come in contact with urine.

Bacteriuria↗