PubMed Health⌕ Search

Biomedical subjects

J A Griggs

Publications and source records attributed to J A Griggs.

7 recordsLinked to original sources

Effect of cryogenic treatment on nickel-titanium endodontic instruments.

AIM: To investigate the effects of cryogenic treatment on nickel-titanium endodontic instruments. The null hypothesis was that cryogenic treatment would result in no changes in composition, microhardness or cutting efficiency of nickel-titanium instruments. METHODOLOGY: Microhardness was measured on 30 nickel-titanium K-files (ISO size 25) using a Vicker's indenter. Elemental composition was measured on two instruments using X-ray spectroscopy. A nickel-titanium bulk specimen was analysed for crystalline phase composition using X-ray diffraction. Half of the specimens to be used for each analysis were subjected to a cryogenic treatment in liquid nitrogen (-196 degrees C) for either 3 s (microhardness specimens) or 10 min (other specimens). Cutting efficiency was assessed by recording operator choice using 80 nickel-titanium rotary instruments (ProFile 20, .06) half of which had been cryogenically treated and had been distributed amongst 14 clinicians. After conditioning by preparing four corresponding canals, each pair of instruments were evaluated for cutting efficiency by a clinician during preparation of one canal system in vitro. A Student's t-test was used to analyse the microhardness data, and a binomial test was used to analyse the observer choice data. Composition data were analysed qualitatively. RESULTS: Cryogenically treated specimens had a significantly higher microhardness than the controls (P < 0.001; beta > 0.999). Observers showed a preference for cryogenically treated instruments (61%), but this was not significant (P = 0.21). Both treated and control specimens were composed of 56% Ni, 44% Ti, 0% N (by weight) with a majority in the austenite phase. CONCLUSIONS: Cryogenic treatment resulted in increased microhardness, but this increase was not detected clinically. There was no measurable change in elemental or crystalline phase composition.

Cold Temperature↗

SEM/EDS evaluation of porcelain adherence to gold-coated cast titanium.

The adhesion between titanium and dental porcelain is related to the diffusion of oxygen to the reaction layer formed on cast-titanium surfaces during porcelain firing. The diffusion of oxygen could be suppressed by coating the titanium surface with a thin gold layer. This study characterized the effects of gold coating on titanium-ceramic adhesion. ASTM grade II CP titanium was cast into a MgO-based investment (Selevest CB, Selec). The specimen surfaces were air abraded with 110-microm Al(2)O(3) particles. Gold coating was applied on titanium surfaces by three methods: gold-paste (Deck Gold NF, Degussa-Ney) coating and firing at 800 degrees C for three times, single gold-paste coating and firing followed by sputter coating (40 mA, 500 s), and sputter coating (40 mA, 1000 s). Surfaces only air abraded with Al(2)O(3) particles were used as controls. An ultra-low-fusing dental porcelain (Vita Titankeramik, Vident) was fused on titanium surfaces. Specimen surfaces were characterized by SEM/EDS and XRD. The titanium-ceramic adhesion was evaluated by a biaxial flexure test (N = 8), and area fraction of adherent porcelain (AFAP) was determined by EDS. Numerical results were statistically analyzed by one-way ANOVA and the Student-Newman-Keuls test at alpha = 0.05. SEM fractography showed a substantial amount of porcelains remaining on the gold-sputter-coated titanium surfaces. A new Au(2)Ti phase was found on gold-coated titanium surface after the firing. Significantly higher (p <.05) AFAP values were determined for the gold-sputter-coated specimens compared to the others. No significant differences were found among the other groups and the control. Results suggested that gold coatings used in this study are not effective barriers to completely protect titanium from oxidation during the porcelain firing, and porcelain adherence to cast titanium can be improved by gold-sputter coating used in the present study.

Dental Porcelain↗

Effects of flaw size and auto-glaze treatment on porcelain strength.

The functional surfaces of porcelain restorations are often ground to adjust occlusion. This removes the surface glaze and introduces flaws. Re-firing the restoration before final placement produces a self-glaze layer on the surface that may reduce the extent of damage caused by grinding. The objectives of this study were to determine whether re-firing after grinding increases the strength of dental porcelain and to determine whether the effectiveness of this treatment was dependent on the initial flaw size. Six groups, each containing 12 disk specimens, were prepared from experimental body porcelain (No. 36, J.F. Jelenko & Co., Armonk, NY). The specimens were fired under vacuum, ground to a thickness of 1 mm with 240-grit SiC abrasive, and polished through 600-grit on the surface to be subjected to tensile stress. Control Group A consisted of 12 non-indented specimens. Flaws were induced in the remaining groups by means of a Vickers indenter under the following loads: 3.9 N (Group B), 7.8 N (Group C), 11.8 N (Group D), 15.7 N (Group E), and 19.6 N (Group F). Following indentation, half of the specimens from each group were re-fired. The flexure strength of each specimen was determined by means of a piston-on-three-ball biaxial fixture. The TTEST procedure of SAS (1985) indicated a significant difference between the mean strength values of glazed and non-glazed specimens in Group E only (p = 0.55, 0.24, 0.13, 0.07, 0.01, and 0.69 for Groups A to F, respectively). ANOVA with the GLM procedure of SAS (1985) revealed that the mean strength values of groups subjected to five indentation loads were not significantly different (p = 0.45 for glazed specimens and p = 1.00 for non-glazed specimens). These findings support those of Fairhurst et al. (1992) for specimens with smaller flaws that were induced by grinding with 1 micron abrasive grit. The results of the current study indicate that re-firing of porcelain with large surface flaws does not significantly increase the flexural strength.

Analysis of Variance↗

Sensitivity of catalyst/base ratio on curing of resin luting agents: polymerization exotherm analysis.

OBJECTIVES: Currently, the proposed test of the International Standardization Organization (ISO) for measuring working and setting times of resin luting agents is based on measurement of times to reach specified stages on the polymerization exotherm. The objective of this study was to use this test to investigate the influence of variations in the mass ratios of catalyst paste to base paste on the working and setting times of three dual-cured dental resin luting agents. METHODS: The materials used were Dicor Light Activated Cement (Dentsply International Inc.), Palfique Inlay Resin Cement (Tokuyama Soda Co.), and Vivadent Dual Cement (Vivadent). Fifteen specimens of each material were tested for working time by spatulating mass ratios from 0.7 to 1.3 for 30s at 23 degrees C and recording the time from beginning of spatulation to the time at which a temperature increase occurs. Ten specimens of each material were tested for setting time by spatulating in a similar manner at 37 degrees C and recording the time at which the temperature reaches a maximum value. RESULTS: The data were fitted to the relation, In t = In A + Bm, where t is the time in seconds, m is the mass ratio, and A and B are regression coefficients. The results suggest that working and setting times of the specimens were independent of variations in mass ratio. A comparison among the materials was made by using a multiple linear regression with the relation, In t = In C + Dm + E gamma + Fm gamma, where gamma is a dummy variable to help distinguish between materials, and C, D, E, and F are regression coefficients. The results suggest that differences in materials influence the working time but not the setting time. SIGNIFICANCE: These results infer that variations in mass ratio (+/- 20%) often observed in the clinical setting should not have a significant influence on the working and setting times of resin luting agents.

Acrylic Resins↗

Mayer-Rokitansky-Kuster-Hauser syndrome with splenosis. A case report.

This is the first reported case of simultaneously occurring pelvic splenosis and Mayer-Rokitansky-Kuster-Hauser syndrome. No other congenital or anatomic abnormalities were observed in the patient, and she had no history of abdominal trauma or surgery. Endometriosis was suspected initially during laparoscopy for pelvic pain. After tissue removal at laparotomy, the histologic evaluation established the diagnosis of splenosis. Biopsy at laparoscopy should be considered to confirm the diagnosis in the presence of a congenital anomaly and lesions suspected of being endometriotic.

Abnormalities, Multiple↗