PubMed Health⌕ Search

Biomedical subjects

J A Horrocks

Publications and source records attributed to J A Horrocks.

10 recordsLinked to original sources

A novel method for producing x-ray test objects and phantoms.

A novel method for producing customized x-ray test objects and clinically realistic phantoms has been developed. Test objects can be created with a drawing software package and the digital images can be printed on a standard inkjet printer but using potassium iodide solution in place of the cartridge's ink. The reproducibility and the consistency, the limiting spatial resolution, the uniformity as well as the potassium iodide thickness per print have been evaluated. The relationship between the number of prints, grey levels and the radiation contrast was investigated and quantified. A copy of the Leeds TO10 contrast detail test object was printed and the x-ray images of the Leeds TO10 and of the printed Leeds TO10 were compared. In addition, the potential use of this method was demonstrated by reproducing a percutaneous transluminal coronary angioplasty clinical digital image. The reproducibility and consistency of this method was found to be better than 0.1%. The limiting spatial resolution of the printer using ink was found to be 3.55 1p mm(-1) but it deteriorated when the ink was replaced with potassium iodide and as the print density increases. The uniformity across the printed area was found to be satisfactory although an artefact due to the printer was present in the x-ray images. The comparison between the Leeds TO10 and the printed Leeds TO10 gave differences less than 10%. A good agreement between the clinical image and the printed clinical image was found. In conclusion, the method is a reliable, cost-effective, flexible and alternative way for producing x-ray test objects and clinically related phantoms.

Air↗

Pharmaceutical interventions for emotionalism after stroke.

BACKGROUND: Antidepressants may be useful in the treatment of abnormal crying associated with stroke. OBJECTIVES: To determine whether pharmaceutical treatment reduces the frequency of emotional displays in people who suffer from emotionalism after stroke. SEARCH STRATEGY: We searched the Cochrane Stroke Group Trials Register (last searched June 2003). In addition we searched the following electronic databases: Cochrane Central Register of Controlled Trials (The Cochrane Library, Issue 3 2002), MEDLINE (1966 to September 2002), EMBASE (1980 to September 2002), CINAHL (1982 to September 2002), PsychINFO (1967 to September 2002), Applied Science and Technology Plus (1986 to September 2002), Arts and Humanities Index (1991 to September 2002), Biological Abstracts (1969 to September 2002), General Science Plus (1994 to September 2002), Science Citation Index (1992 to September 2002), Social Sciences Citation Index (1991 to September 2002), and Sociofile (1974 to September 2002). We searched reference lists from relevant articles and textbooks, and contacted authors of known studies and pharmaceutical companies who manufacture psychotropic medications. SELECTION CRITERIA: Randomised and quasi-randomised controlled trials, comparing psychotropic medication to placebo, in people with stroke and emotionalism (also known as emotional lability or pathological crying and laughing). DATA COLLECTION AND ANALYSIS: Data were obtained on people who no longer met criteria for emotionalism, as defined in studies, and on reduction in frequency of crying at the end of treatment. Data were not pooled because of the multiplicity of definitions and outcome measures. MAIN RESULTS: Five trials involving 103 participants were included. Four trials showed large effects of treatment: 50% reduction in emotionalism, improvements (reduction) in the frequency of compulsive laughter, and lower (better) scores on the Pathological Laughter and Crying scale. The confidence intervals were wide, however, indicating that treatment may have had only a small positive effect, or even a small negative effect (in one trial). Subgroup analysis was not performed due to the multiple methods of assessment of emotionalism within and between trials. Only one study systematically recorded and reported adverse events; no discernible difference was seen between groups. Participants allocated active treatment were more likely to leave early from trials. REVIEWERS' CONCLUSIONS: Antidepressants can reduce the frequency and severity of crying or laughing episodes. The effect do not seem specific to one drug or class of drugs. However, our conclusions must be qualified by several methodological deficiencies in the studies. More reliable data are required before recommendations can be made about the treatment of post-stroke emotionalism.

Antidepressive Agents↗

A study on radiation doses and irradiated areas in cerebral embolisation.

Patient radiation doses during interventional radiology procedures may reach the thresholds for radiation-induced skin and eye lens injuries. This study investigates the irradiated areas and doses received by patients undergoing cerebral embolisation, which is regarded as a high dose interventional radiology procedure. For each procedure the fluoroscopic and digital dose-area product (DAP), the fluoroscopic time, the total number of acquired images and entrance-skin dose (ESD) calculated by the angiographic unit were recorded. The ESD was measured by means of thermoluminescent dosimeters. In this study, the skin, eye and thyroid gland doses and the irradiated area for 30 patients were recorded. The average ESD was found to be 0.77 Gy for the posteroanterior plane and 0.78 Gy for the lateral plane. The average DAP was 48 Gy cm(2) for the posteroanterior plane and 58 Gy cm(2) for the lateral plane. The patient's average right eye dose was 60 mGy and the dose to the thyroid gland was 24 mGy. Seven patients received a dose above 1 Gy, one patient exceeded the threshold for transient erythema and one exceeded the threshold for temporary epilation. A good correlation between the DAP and the ESD for both planes has been found. The doctor's eye dose has also been measured for 17 procedures and the average dose per procedure was 0.13 mGy.

Embolization, Therapeutic↗

Quantitative analysis of herpesvirus sequences from normal tissue and fibropapillomas of marine turtles with real-time PCR.

Quantitative real-time PCR has been used to measure fibropapilloma-associated turtle herpesvirus (FPTHV) pol DNA loads in fibropapillomas, fibromas, and uninvolved tissues of green, loggerhead, and olive ridley turtles from Hawaii, Florida, Costa Rica, Australia, Mexico, and the West Indies. The viral DNA loads from tumors obtained from terminal animals were relatively homogeneous (range 2-20 copies/cell), whereas DNA copy numbers from biopsied tumors and skin of otherwise healthy turtles displayed a wide variation (range 0.001-170 copies/cell) and may reflect the stage of tumor development. FPTHV DNA loads in tumors were 2.5-4.5 logs higher than in uninvolved skin from the same animal regardless of geographic location, further implying a role for FPTHV in the etiology of fibropapillomatosis. Although FPTHV pol sequences amplified from tumors are highly related to each other, single signature amino acid substitutions distinguish the Australia/Hawaii, Mexico/Costa Rica, and Florida/Caribbean groups.

Amino Acid Sequence↗

The effect of decreasing mAs on image quality and patient dose in sinus CT.

The aim of this study was to determine the effect of reducing mAs on the diagnostic quality of images and the radiation dose to the orbits in patients undergoing sinus CT. We studied 40 consecutive patients undergoing paranasal sinus CT for inflammatory disease prior to functional endoscopic sinus surgery (FESS). Four groups of 10 patients were scanned at 200 mAs, 150 mAs, 100 mAs and 50 mAs, respectively. Orbital radiation dose was measured using thermoluminescent dosemeters. Images were reviewed independently by two observers who were unaware of the mAs setting used. Image quality was evaluated using a semi-quantitative scoring system for six anatomical structures. The osteomeatal complex, uncinate process, infundibulum, frontal recess, middle turbinate and optic nerve were assessed as: clearly demonstrated (2 points); demonstrated but not clearly visualized (1 point); or not seen (0 points). No significant difference was shown between any of the four groups in terms of image quality according to the scoring system used in this study. Mean radiation dose to the orbit was reduced by 77%, from 13.5 mGy at 200 mAs to 3.1 mGy at 50 mAs (p<0.05). CT of the sinuses can be performed in patients prior to FESS at greatly reduced mAs without loss of diagnostic quality of the images. This is important in reducing the radiation dose to the lens.

Analysis of Variance↗

Low-angle X-ray scattering signatures of urinary calculi.

This is the first reported use of low-angle X-ray scattering for the investigation of urinary calculi. Low-angle X-ray scattering (LAXS) measures the diffraction of a broad spectrum of X-rays at a single angle and uses a conventional diagnostic X-ray beam, and could thus be developed for use in vivo. A total of 45 calculi were investigated using this technique. Calcium oxalate stones showed a bimodal signature with peaks of almost even photon energies. Signatures for the other stone types were less well-defined. The results are discussed in more detail below. Our preliminary results show that the technique is capable of distinguishing between calcium oxalate stones and other stone types in vitro. Further work is in progress to correlate the results of this technique with objective parameters of stone hardness.

Humans↗

Testing models of female reproductive migratory behaviour and population structure in the Caribbean hawksbill turtle, Eretmochelys imbricata, with mtDNA sequences.

Information on the reproductive behaviour and population structure of female hawksbill turtles, Eretmochelys imbricata, is necessary to define conservation priorities for this highly endangered species. Two hypotheses to explain female nest site choice, natal homing and social facilitation, were tested by analyzing mtDNA control region sequences of 103 individuals from seven nesting colonies in the Caribbean and western Atlantic. Under the social facilitation model, newly mature females follow older females to a nesting location, and subsequently use this site for future nesting. This model generates an expectation that female lineages will be homogenized among regional nesting colonies. Contrary to expectations of the social facilitation model, mtDNA lineages were highly structured among western Atlantic nesting colonies. These analyses identified at least 6 female breeding stocks in the Caribbean and western Atlantic and support a natal homing model for recruitment of breeding females. Reproductive populations are effectively isolated over ecological time scales, and recovery plans for this species should include protection at the level of individual nesting colonies.

Animals↗

Short communication: helical computed tomography: where is the cut?

The helical scanning mode in computed tomography (CT) entails continuous table movement during image acquisition. The projections acquired in this mode will not be consistent with those in the axial scanning mode. A comparison of the helical and axial modes of scanning on the IGE HiSpeed Advantage CT system (software version ZA) has been made using a contrast-detail phantom. Differences seen between the two modes include shadow and streaking artefacts and an increase in the partial volume effect in the helical scan mode.

Humans↗

A Monte Carlo study of multiple scatter effects in Compton scatter densitometry.

The contribution of multiple scatter to the measured signal in x- and gamma-ray Compton scatter densitometry has been investigated theoretically by the use of Monte Carlo techniques to follow individual photon life histories. A three component phantom was employed in the computer model to simulate the patient at three examination sites; the radius/ulna, the femoral neck, and the lumbar spine. Monoenergetic radiation beams of 60- and 100-keV photons and polyenergetic x-ray spectra of 100 and 140 kVp were used. Scattered events were detected over 360 degrees and classified according to their origin and frequency of scatter. The single scatter in bone to multiple scatter ratio was studied as an indication of the signal-to-noise ratio and this was found to vary with phantom size but was independent of photon energy. Correction factors to be used in a clinical densitometer to account for the inclusion of multiple scatter events were computed. These were found to be 0.65-0.58 at the optimum scattering angles for the phantoms considered.

Absorptiometry, Photon↗