Host inflammatory response to NiCr, CoCr, and Ti in a soft tissue implantation model.

The inflammatory response to nickel chromium (NiCr), cobalt chromium (CoCr), and titanium (Ti) implants at 7 and 28 days was investigated using real-time PCR analysis along with histological and immunohistochemical staining. Contrasting inflammatory profiles were found in response to the different metal compositions. The inflammatory profile induced by CoCr remained consistent and elevated during the 28-day period with high cell counts associated with the implants and a progressive recruitment of T lymphocytes. The response to NiCr was also elevated, but with an initially low T-lymphocyte infiltration that increased by the later time period. Ti indicated an early increased inflammatory response that had reduced by 28 days. Changes in gene expression demonstrated that Ti induced very low levels of expression of the three inflammatory cytokine genes. NiCr initiated a significant upregulation in gene expression for IL-6 and TNF-alpha. CoCr resulted in the highest upregulation of IL-2 indicative of T-lymphocyte activation to this material.

Animals↗

Flow cytometric measurement of phagocytosis reveals a role for C3b in metal particle uptake by phagocytes.

A methodology for the quick and efficient study of phagocytosis has been developed. It uses the flow cytometer to exploit the change in size and granularity that occurs in cells upon the ingestion of particulate material. The numbers of cells that have phagocytosed particles can be calculated from the distinct shift in regions that occurs. The method also allows the factors governing phagocytosis to be studied in detail through the use of blocking agents or antibodies. Blood-derived monocytes were studied to investigate the role of complement in metal particle phagocytosis to further understand aseptic loosening. Factor C3b was found to be fundamental to the opsonization and phagocytosis of metal particles by monocytes.

Antibodies↗

The effect of starch-based biomaterials on leukocyte adhesion and activation in vitro.

Leukocyte adhesion to biomaterials has long been recognised as a key element to determine their inflammatory potential. Results regarding leukocyte adhesion and activation are contradictory in some aspects of the material's effect in determining these events. It is clear that together with the wettability or hydrophilicity/hydrophobicity, the roughness of a substrate has a major effect on leukocyte adhesion. Both the chemical and physical properties of a material influence the adsorbed proteins layer which in turn determines the adhesion of cells. In this work polymorphonuclear (PMN) cells and a mixed population of monocytes/macrophages and lymphocytes (mononuclear cells) were cultured separately with a range of starch-based materials and composites with hydroxyapatite (HA). A combination of both reflected light microscopy and scanning electron microscopy (SEM) was used in order to study the leukocyte morphology. The quantification of the enzyme lactate dehydrogenase (LDH) was used to determine the number of viable cells adhered to the polymers. Cell adhesion and activation was characterised by immunocytochemistry based on the expression of several adhesion molecules, crucial in the progress of an inflammatory response. This work supports previous in vitro studies with PMN and monocytes/macrophages, which demonstrated that there are several properties of the materials that can influence and determine their biological response. From our study, monocytes/macrophages and lymphocytes adhere in similar amounts to more hydrophobic (SPCL) and to moderately hydrophilic (SEVA-C) surfaces and do not preferentially adhere to rougher substrates (SCA). Contrarily, more hydrophilic surfaces (SCA) induced higher PMN adhesion and lower activation. In addition, the hydroxyapatite reinforcement induces changes in cell behaviour for some materials but not for others. The observed response to starch-based biodegradable polymers was not significantly different from the control materials. Thus, the results reported herein indicate the low potential of the starch-based biodegradable polymers to induce inflammation especially the HA reinforced composite materials.

Biocompatible Materials↗

Attachment, morphology and adherence of human endothelial cells to vascular prosthesis materials under the action of shear stress.

In an effort to improve the long-term patency of vascular prostheses several groups now advocate seeding autologous endothelial cells (ECs) onto the lumen of the vessel prior to implantation, a procedure that involves pre-treating the prosthesis material with fibrin, collagen and/or other matrix molecules to promote cell attachment and retention. In this study, we examined the degree to which human umbilical venous endothelial cells (HUVECs) adhered to three materials commonly used polymeric vascular prosthesis that had been coated with the same commercial extra cellular matrix proteins, and after exposure to fluid shear stresses representative of femoro-distal bypass in a cone-and-plate shearing device. We quantified cell number, area of coverage and degree of cell spreading using image analysis techniques. The response of cells that adhered to the surface of each material, and following exposure to fluid shear stress, depended on surface treatment, topology and cell type. Whereas collagen coating improved primary cellular adhesion and coverage significantly, the degree of spreading depended on the underlying surface structure and on the application of the shear stress. In some cases, fewer than 30% of cells remained on the surface after only 1-h exposure to physiological levels of shear stress. The proportion of the surface that was covered by cells also decreased, despite an increase in the degree to which individual cells spread on exposure to shear stress. Moreover, the behaviour of HUVECs was distinct from that of fibroblasts, in that the human ECs were able to adapt to their environment by spreading to a much greater extent in response to shear. The quality of HUVEC attachment, as measured by extent of cell coverage and resistance to fluid shear stress, was greatest on expanded polytetrafluoroethylene samples that had been impregnated with Type I/III collagen.

Blood Vessel Prosthesis↗

The physical properties and response of osteoblasts to solution cast films of PLGA doped polycaprolactone.

Polycaprolactone films doped with poly(lactide-co-glycolide) (65:35) in 0, 10, 20, and 30 (wt%) were prepared and evaluated in terms of morphology, dynamic contact angle analysis, and thermal properties. The unique surface morphology of the doped PCL film resulted, without introducing significant microstructure disruption of PCL aggregation. The doped PCL film registered a lower contact angle and increased hydrophilicity. Osteoblast cells attached to all doped materials, the 10% and 20% doped materials demonstrating the greatest cell growth.

Actins↗

Controlling the phenotype and function of mesenchymal stem cells in vitro by adhesion to silane-modified clean glass surfaces.

The behaviour of human mesenchymal stem cells (hMSC) when cultured in contact with a range of silane-modified surfaces was examined to determine if changing the surface chemistry affected the early differentiation potential of mesenchymal stem cells in vitro over a 7-day period. Cells were cultured for 1 and 7 days in direct contact with glass which had been functionalized by surface treatment to provide a range of different surfaces: -CH(3), -NH(2), -SH, -OH, and -COOH modified surfaces and a clean glass reference (TAAB). Viable cell adhesion was quantified by Lactate Dehydrogenase assay, and morphology and viability was qualitatively evaluated using calcein AM, ethidium homodimer, cytoskeletal (F Actin), extra-cellular matrix (fibronectin and vitronectin) and Hoechst staining (nucleus). The expression of selected differentiation markers, Collagen II (chondrocytes), CBFA1 (bone transcription factor), Collagen I (MSC marker) and TGF-beta3 (extra-cellular matrix production) was determined using real time polymerase chain reaction. The expression of ornithine decarboxylase was evaluated as a marker of proliferation. Surfaces of the -NH(2) group demonstrated the greatest level of cell adhesion by the 7-day period, and mRNA expression profiles indicated osteogenic differentiation, increased CBFA1 and decreased Collagen II expression. Cells cultured in contact with the -COOH surfaces displayed different cell morphologies, fibronectin and vitronectin spatial distributions compared with the cells in contact with the -NH(2) surfaces, in addition to an increase in Collagen II expression, indicative of chondrogenic differentiation. The modifications to the surface chemistry of glass did affect cell behaviour, both in terms of viable cell adhesion, morphology and profiles of mRNA expression, providing the means to alter the differentiation potential of the MSCs.

Cell Adhesion↗

Surface properties and biocompatibility of solvent-cast poly[-caprolactone] films.

Poly(epsilon-caprolactone) (PCL) was dissolved in four solvent systems, chloroform, tetrahydrofuran, acetone and ethyl acetate, and cast onto glass Petri dishes. The surface properties of the resulting films were investigated. The extent to which their properties were determined by the solvent used in each case was quantified in terms of contact angle, surface morphology, attenuated total reflection-Fourier transform infrared spectroscopy (ATR-FTIR), and the adhesion and proliferation of fibroblasts by direct contact. The surface of the PCL film in contact with glass was denoted the SG surface, and the other, which was exposed to the gas phase, a mixture of air and residual solvent vapour, was denoted the SA surface. In the case of hydrophobic solvent systems, the advancing contact angle of the SG surface was always lower than that of the SA surface. With hydrophilic solvent systems, on the other hand, the advancing contact angle of the SG film surface was higher when the contact angle of the Petri dish was higher than that of the gaseous mixture of the air and solvent vapour, otherwise it was lower or equal to that of the surface on which it was cast. The surface morphology was dictated by the solubility of PCL in the respective solvent systems: high dissolution solvents such as chloroform and tetrahydrofuran produced films that comprised PCL aggregates, the particles being larger in the case of chloroform, whereas the less efficient solvents (acetone and ethyl acetate) resulted in a filamentous structure. The ATR-FTIR results confirmed that the chemistry of the SA surfaces differed according to the solvent system used. Preliminary cell culture experiments carried out with the PCL films established that murine (L929) fibroblasts grew well on all surfaces regardless of the solvent used, although the rates of adhesion and proliferation were not as great as on tissue culture plastic controls. Of all the surfaces examined in this study, the cells favoured the SG aspect of ethyl acetate cast PCL films, the surface of which had the finest pore size and relatively low contact angle.

Animals↗

Hydrophilicity of 3-D biomaterials: the Washburn equation.

Characterisation and quantification of the surface energy of biomaterials used as tissue engineering scaffolds is important, but many of the techniques available to examine these properties are only applicable to smooth flat samples, not porous materials. This paper describes the application of the Washburn equation to measure the surface energy of a range of porous polyether polyurethane scaffolds with three test liquids; n-Hexane was used to measure a material constant, whilst ethanol and xylene were used to measure contact angles. The results show that the Washburn equation is not applicable in its current form, reasons for this could be that the voids in the materials are too wide for effective capillarity; absorption of the solvents into the polymer matrix may further complicate the measured imbibition profile. Another possible reason is the differences between the sizes of the interconnecting pores in scaffolds with varying void sizes; this could affect the capillary effect of the test liquids through the material. The repeatability of the results and the similar patterns observed with the different liquids suggest that if these issues could be quantified and incorporated into the Washburn equation, it may be possible to generate useful results for similar materials.

Absorption↗

Quantitative evaluation of the biocompatible and osteogenic properties of a range of biphasic calcium phosphate (BCP) granules using primary cultures of human osteoblasts and monocytes.

A range of 50% porous gamma-sterilized biphasic calcium phosphate (BCP) granules, (20, 50, 80, and 100% tricalcium phosphate, TCP) were classified into two distinct size ranges, small 2-4 mm in diameter and large 4-6 mm in diameter, and their potential as bone graft extender materials was assessed in vitro using culture systems of primary-derived peripheral human blood monocytes and human osteoblasts isolated from bone. The effect of the in vitro culture conditions was evaluated prior to the introduction of the test substrates. The cellular response was assessed via quantification of viable cell adhesion to the materials, lactate dehydrogenase (LDH), the production and release of interleukin-1beta (IL-1beta), tumor necrosis factor alpha (TNF-alpha), and prostaglandin E2 (PGE2). The higher content TCP materials, 80% and 100% TCP, had a detrimental effect on viable cell adhesion after day 1, which was not related to calcium release from the granules within the local environment. TCP granules (20% and 50%) initiated a controlled level of inflammatory response that sustained and promoted viable macrophage adhesion throughout the test period, The percentage of TCP within the BCP granules was a governing factor in determining the cellular response.

Biocompatible Materials↗

Quantitative assessment of the response of primary derived human osteoblasts and macrophages to a range of nanotopography surfaces in a single culture model in vitro.

The effect of nanotopography on a range of Ti oxide surfaces was determined. Flat Ti, 3%, 19%, 30% and 43% topography densities of 110 nm high hemispherical protrusions were cultured in contact with primary derived human macrophages and osteoblasts in single culture models. Prior to introduction of the test substrate the phenotype and optimum conditions for in vitro cell culture were established. The cellular response was investigated and quantified by assessments of cytoskeletal development and orientation, viable cell adhesion, cytokine production and release and RT-PCR analysis of osteogenic markers. The tested nanotopographies did not have a statistically significant effect on viable cell adhesion and subsequent cytoskeletal formation. Surface chemistry was the dominant factor as established via incorporation of a tissue culture polystyrene, TCPS, control. The topography surfaces induced a release of chemotactic macrophage activation agents at 1 day in conjunction with stress fibre formation and a subsequent fibronectin network formation. Osteoblasts migrated away from the topography surfaces to the exposed TCPS within the wells during the 7-day period.

Cell Adhesion↗

Preliminary study on human protein adsorption and leukocyte adhesion to starch-based biomaterials.

In this study, the adsorption of human serum albumin (HSA), fibronectin (FN) and vitronectin (VN) onto the surface of novel biodegradable materials was evaluated by immunostaining. Specifically, polymeric blends of corn starch with cellulose acetate (SCA), ethylene vinyl alcohol copolymer (SEVA-C), and polycaprolactone (SPCL) were immersed in unitary and competitive systems; that is, binary and more complex protein solutions. For binary solutions, different HSA and FN protein distribution patterns were observed depending on the starch-based surface. Furthermore, the relative amount of proteins adsorbed onto starch-based surfaces was clearly affected by protein type: a preferential adsorption of VN and FN as compared to HSA was observed. On tests carried out with unitary, binary and more complex solutions, it was found that vitronectin adsorption ability was enhanced in competitive systems, which was associated with a lower amount of adsorbed albumin. In order to assess the effect of these human proteins on cell behavior, a mixed population of human lymphocytes and monocytes/macrophages was cultured over pre-coated SEVA-C surfaces. Through anti-CD3 and CD-14 monoclonal antibody labeling and cell counting, leukocyte adhesion onto pre-coated SEVA-C surfaces was analyzed. Based on the results, it was possible to detect albumin long-term effects and fibronectin short-term effects on cell adhesion proving that previously adsorbed proteins modulate leukocyte behavior.

Journal Article↗

Evaluation of the potential of starch-based biodegradable polymers in the activation of human inflammatory cells.

The inflammatory response resulting from the implantation of a medical device may compromise its performance and efficiency leading, in certain cases, to the failure of the implant. Thus, the assessment of the behavior of inflammatory cells in vitro, constitutes a key feature in the evaluation of the adverse potential, or not, of new promising biomaterials. The objectives of this study were to determine whether starch-based polymers and composites activated human neutrophils. Blends of starch with ethylene-vinyl alcohol, with cellulose acetate and polycaprolactone, as well as composites based on all these materials filled with hydroxyapatite have been studied. A lysozyme assay was adapted to examine enzyme secretion from human neutrophils incubated with different starch-based materials. Changes in the free radical and degranulation activity of the neutrophil were also determined by measuring the luminescent response of Pholasin, a photoprotein that emits light after excitation by reactive oxygen species. The amount of lysozyme secreted by neutrophils incubated with the polymers did not exhibit significant differences between the tested materials. Results were in all cases similar to those obtained for the control (polypropylene) except for one of the starch blends (corn starch with polycaprolactone reinforced with 30% (w/w) of HA). The chemiluminescence experiments showed that polymers reduce the signal produced by activated neutrophils. Furthermore, for some polymers it was demonstrated that the phenomenon was due to an effect of the surface of the materials in cell adhesion or a simultaneous competition for the photoprotein in solution, which results in the decrease of the intensity of light emitted and detected.

Journal Article↗

The biocompatibility of novel starch-based polymers and composites: in vitro studies.

Studies with biodegradable starch-based polymers have recently demonstrated that these materials have a range of properties. which make them suitable for use in several biomedical applications, ranging from bone plates and screws to drug delivery carriers and tissue engineering scaffolds. The aim of this study was to screen the cytotoxicity and evaluate starch-based polymers and composites as potential biomaterials. The biocompatibility of two different blends of corn-starch, starch ethylene vinyl alcohol (SEVA-C) and starch cellulose acetate (SCA) and their respective composites with hydroxyapatite (HA) was assessed by cytotoxicity and cell adhesion tests. The MTT assay was performed with the extracts of the materials in order to evaluate the short-term effect of the degradation products. The cell morphology of L929 mouse fibroblast cell line was also analysed after direct contact with polymers and composites for different time periods and the number of cells adhered to the surface of the polymers was determined by quantification of the cytosolic lactate dehydrogenase (LDH) activity. Both types of starch-based polymers exhibit a cytocompatibility that might allow for their use as biomaterials. SEVA-C blends were found to be the less cytotoxic for the tested cell line, although cells adhere better to SCA surface. The cytotoxicity test also revealed that SCA and SEVA-C composites have a similar response to the one obtained for SCA polymer. Scanning electron microscopy (SEM) analysis showed that cells were much more spread on the SCA polymer and LDH measurements showed a higher number of cells on this surface.

Animals↗

Effects of plasma treated PET and PTFE on expression of adhesion molecules by human endothelial cells in vitro.

The aim of this study was to evaluate the expression of adhesion molecules on the surface of human endothelial cells in response to the systematic variation in materials properties by the ammonia plasma modification of polyethylene terephthalate (PET) and polytetrafluorethylene (PTFE). These adhesion molecules act as mediators of cell adhesion, play a role in the modulation of cell adhesion on biomaterials and therefore condition the response of tissues to implants. First and second passage human umbilical vein endothelial cells (HUVECs) were cultured on plasma treated and untreated PET and PTFE. HUVECs grown on polystyrene tissue culture coverslips and HUVECs stimulated with tumour necrosis factor (TNF-alpha) were used as controls. After 1 day and 7 days, the expression of adhesion molecules platelet endothelial cell adhesion molecule-1 (PECAM-1), intercellular adhesion molecule-1 (ICAM-1), Integrin alphavbeta3, vascular cell adhesion molecule-1 (VCAM-1), E-selectin, P-selectin and L-selectin were evaluated using flow cytometry and immunohistochemistry. There was a slight increase in positive cell numbers expressing the adhesion molecules ICAM-1 and VCAM-1 on plasma treated PET and PTFE. A significant increase in E-selectin positive cells on untreated PTFE was demonstrated after 7 days. Stimulation with TNF-alpha demonstrated a significant increase in the proportion of ICAM-1. VCAM-1 and E-selectin positive cells. Almost all cells expressed PECAM-1 and integrin alphavbeta3, on both materials and controls but did not express P- and L-selectin on any surface. When second passage cells were used, the expression of the adhesion molecules ICAM-1 and VCAM-1 was markedly increased on all surfaces but not with TNF-alpha. These significant differences were not observed in other adhesion molecules. These results were supported by immunohistochemical studies. The effects of plasma treated PET and PTFE on cell adhesion and proliferation was also studied. There was a 1.3-fold increase in cell numbers adhered on ammonia plasma treated PET compared to untreated PET and a 5.5-fold increase in cell numbers on treated PTFE compared to untreated PTFE after 1 day. This is significantly different when analysed statistically. After 7 days, cell number increased significantly on all surfaces compared to 1 day, except for untreated PTFE which conversely reduced by 41%. Cell number on the surface of untreated PET was no different to treated PET on days 1 and 7 when second passage cells were used. The study has shown that the plasma treatment of PET and PTFE with ammonia improves the adhesion and growth of endothelial cells and slightly upregulates the expression of adhesion molecules. This surface modification should promote colonisation of an artificial vascular prosthesis by endothelial cells and make it less vulnerable to immune system cells of the recipient. In addition, it should be considered which passage of cells is used due to the different adhesion features of different passages of HUVECs on untreated PET.

Biocompatible Materials↗

A study of tissue interface membranes from revision accord knee arthroplasty: the role of T lymphocytes.

Despite four decades of advances in the design of orthopaedic devices aseptic loosening remains a major cause for the revision of total joint arthroplasty. This study used the techniques of immunohistochemistry and reverse transcription polymerase chain reaction to identify the inflammatory cell types, cytokines and chemokines within the interface tissue surrounding failed Accord Knee prostheses. Many T cells were identified within the tissue: however, the classical marker of activation, CD25 was expressed on very few cells. Molecular analysis failed to detect the synthesis of either Th1 or Th2 cytokines. These results suggest that the T cells are being actively recruited to the site of inflammation along the chemokine gradients but are not participating in a classical immune response.

Aged↗

Expression of leukocyte-endothelial cell adhesion molecules on monocyte adhesion to human endothelial cells on plasma treated PET and PTFE in vitro.

We used a coculture model to evaluate the inflammatory potential of ammonia gas plasma modified PET and PTFE by flow cytometry and immunohistochemistry. In these studies, human endothelial cells from umbilical cord (HUVEC) and promonocytic U937 cells were used. HUVECs grown on polystyrene tissue culture coverslips and HUVECs stimulated with tumour necrosis factor (TNF-alpha) were used as controls. U937 adhesion to endothelium on each surface was evaluated at day 1 and day 7. To further investigate the role of leukocyte-endothelial cell adhesion molecules (CAMs) in cell-to-cell interaction on material surfaces, the expression of the leukocyte-endothelial CAMs: ICAM-1, VCAM-1, PECAM-1, and E-selectin on HUVECs were evaluated after U937 cell adhesion. The results demonstrated that plasma treated PET (T-PET) and treated PTFE (T-PTFE) did not increase U937 cell adhesion compared to the negative control. Maximal adhesion of U937 cells to HUVEC was observed on TNF-alpha stimulated endothelium with significant differences between day 1 and day 7, which is consistent with our prior observation that T-PET and T-PTFE did not cause HUVECs to increase the expression of adhesion molecules. After U937 cell adhesion, the expression of ICAM-1 and VCAM-1 of HUVECs were not different on T-PET and T-PTFE compared with the negative control. However, the expression of E-selectin was reduced on day 1, but not on day 7. The effects of plasma treated PET and PTFE on HUVEC adhesion and proliferation were also studied. On day 1 there were slight increases in the growth of HUVECs on both of T-PET and T-PTFE but this was not statistically significant. On day 7, the cell number increased significantly on the surfaces compared to the negative control. The results demonstrate that the plasma treatment of PET and PTFE with ammonia improves the adhesion and growth of endothelial cells and these surfaces do not exhibit a direct inflammatory effect in terms of monocyte adhesion and expression of leukocyte-endothelial CAMs. The monocyte adhesion to endothelial cells on surfaces can be used as a tool for the evaluation of material surface modification and further to study the mechanisms of cell-to-cell interactions in response to surfaces.

Biocompatible Materials↗

The influence of bracket type on the force delivery of Ni-Ti archwires.

This study investigated the force delivery of an 0.014 inch nickel-titanium (Ni-Ti) archwire used in combination with a range of commercially available bracket systems, and using a model based on an 'ideal' mandibular archform. The model aimed to replicate the clinical interbracket span. The force delivery was measured at four different sites on an archwire for one batch of 10 nickel titanium archwires from one manufacturer, using one bracket/archwire combination. The four sites represented the lateral incisor, canine, second premolar and first molar positions. Force delivery was also measured for a further four different bracket designs at four different sites on the archwire using five fresh wires of the same archwire type. The wires were loaded with an M5 Nene Universal testing machine. The results demonstrate that the peak and plateau force, both of which are clinically important, are dependent on several factors of the archwire/bracket combination. The results showed that 20 per cent of the batch of 10 wires behaved differently by delivering a higher peak force. There was a statistically significant difference (P < 0.05) between the four bracket/archwire combinations for the peak forces delivered, but there was very little difference between the four bracket/archwire unloading force delivery values. The wires delivered a predictable force on the unloading curves, but self-ligating brackets may not develop sufficient strain within the wire to take full advantage of the superelastic effect of Ni-Ti wires.

Dental Stress Analysis↗

Structural influence of hydrophobic core residues on metal binding and specificity in carbonic anhydrase II.

Aromatic residues in the hydrophobic core of human carbonic anhydrase II (CAII) influence metal ion binding in the active site. Residues F93, F95, and W97 are contained in a beta-strand that also contains two zinc ligands, H94 and H96. The aromatic amino acids contribute to the high zinc affinity and slow zinc dissociation rate constant of CAII [Hunt, J. A., and Fierke, C. A. (1997) J. Biol. Chem. 272, 20364-20372]. Substitution of these aromatic amino acids with smaller side chains enhances Cu(2+) affinity while decreasing Co(2+) and Zn(2+) affinity [Hunt, J. A., Mahiuddin, A., & Fierke, C. A. (1999) Biochemistry 38, 9054-9062]. Here, X-ray crystal structures of zinc-bound F93I/F95M/W97V and F93S/F95L/W97M CAIIs reveal the introduction of new cavities in the hydrophobic core, compensatory movements of surrounding side chains, and the incorporation of buried water molecules; nevertheless, the enzyme maintains tetrahedral zinc coordination geometry. However, a conformational change of direct metal ligand H94 as well as indirect (i.e., "second-shell") ligand Q92 accompanies metal release in both F93I/F95M/W97V and F93S/F95L/W97M CAIIs, thereby eliminating preorientation of the histidine ligands with tetrahedral geometry in the apoenzyme. Only one cobalt-bound variant, F93I/F95M/W97V CAII, maintains tetrahedral metal coordination geometry; F93S/F95L/W97M CAII binds Co(2+) with trigonal bipyramidal coordination geometry due to the addition of azide anion to the metal coordination polyhedron. The copper-bound variants exhibit either square pyramidal or trigonal bipyramidal metal coordination geometry due to the addition of a second solvent molecule to the metal coordination polyhedron. The key finding of this work is that aromatic core residues serve as anchors that help to preorient direct and second-shell ligands to optimize zinc binding geometry and destabilize alternative geometries. These geometrical constraints are likely a main determinant of the enhanced zinc/copper specificity of CAII as compared to small molecule chelators.