A randomized comparison of vacuum extraction delivery with a rigid and a pliable cup.

OBJECTIVE: To compare the effectiveness and complications of obstetric vacuum extraction with a rigid and a pliable cup, with a focus on neonatal retinal hemorrhage. METHODS: One hundred women requiring assisted delivery who met predefined criteria for vacuum extraction were randomly assigned to be delivered by the classic rigid Malmström cup or the pliable Silastic cup. RESULTS: Because of the faster induction of vacuum, delivery occurred more rapidly with the pliable cup, but the pliable cup detached significantly more often than the rigid cup. The overall failure rate was not significantly different between the cups. There were no significant differences between the groups with regard to Apgar scores, umbilical artery pH, birth canal trauma, or maternal blood loss, but scalp injury occurred less frequently with the soft than with the rigid cup. Retinal hemorrhage in the newborns showed a similar incidence of about 50%, and neonatal neurologic examination showed no significant differences between the groups. CONCLUSION: In comparison with the rigid cup, the advantage of the pliable cup is limited to a smaller incidence of neonatal scalp injury.

Adult↗

The pliable obstetrical vacuum cup: application and opinions in The Netherlands.

A questionnaire was sent to all hospital obstetric units in The Netherlands to obtain information about the use of soft cups for vacuum extraction. Over 90% of the 156 units responded. Vacuum extraction was used twice as often as forceps for instrumental vaginal delivery. In 12 units the flexible cup was applied in the majority of vacuum extractions and without specific restrictions. In 47 units a minority of vacuum extractions was performed with a flexible cup: its use was generally restricted to anticipated easy low outlet extractions. It is concluded that in The Netherlands the flexible cup is an accepted instrument used in about 13% of vacuum extraction deliveries.

Female↗

Evaluation of a new catheter for esophageal pH monitoring.

A new catheter, provided with an Ion Sensitive Field Effect Transistor as a pH sensor and incorporating a reference electrode, was evaluated for esophageal pH recording. The pH-sensitivity was 54 mV/pH in vitro, with a linear response between pH 2 and pH 9. Clinical semi-ambulatory 24-hour esophageal pH recordings were carried out in 6 adults and 15 infants. System drift after 24-hour in vivo recording was 0.14 pH units +/- 0.10 pH units, and -0.01 pH units +/- 0.10 pH units, in pH 4.0 and pH 7.0 calibration solution, respectively, in the pediatric group (n = 15). It is concluded that the reusable catheter combines accurate esophageal pH monitoring with optimum patient comfort.

Adult↗