Craniomandibular dysfunction among an edentulous Canadian population.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to J A McCarthy.
Explore the source record for details and available documents.
Flexor tendon function following excision of various portions of the fibro-osseous pulley system was measured biomechanically using a tensile testing machine. The biomechanical parameters measured were tendon excursion (the excursion of the tendon required to fully flex the digit) and work of flexion (the area under the force-excursion curve, representing all the forces that resist tendon flexion). In this experiment, work of flexion included the forces necessary to accomplish full digital flexion against a 15-g counter-weight, as well as the frictional forces that resist tendon gliding. The results indicate that the work of flexion was affected to a greater degree by pulley loss than was tendon excursion, suggesting that it is a more sensitive measurement of tendon function. A2 was found to be the single most important pulley for flexor tendon function, followed by A4. However, both A2 and A4 had to be present if near-normal hand function was to be achieved; sacrificing the A1 pulley was not associated with a significant loss of flexion. The "pulley effect" of the skin and soft tissue as a supplement to the fibro-osseous pulleys in reducing tendon bow-stringing was also noted. Although the parameters of tendon excursion and work of flexion were used in this study to determine the effect of pulley loss on tendon function, they can also be used to evaluate other flexor tendon studies, such as pulley reconstruction.
A model was developed to evaluate continuous passive motion as an adjunct to tenolysis. The use of continuous passive motion after tenolysis was associated with a significant increase in tendon rupture and the terminal force necessary to flex the phalanx actively. Also, there was a decrease in the passive range of motion in the continuous passive motion group which appeared to be the result of increased granulation tissue which formed around tenolysed tendon.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
These static creep characteristics indicate that under functional loads Coe-Comfort could behave satisfactorily as a tissue-conditioning material for periods up to 1 week, particularly for the first 24 hours postinsertion. However, the absence of published data on the tissue loads exerted by dentures in their resting state precludes making judgments as to the absolute efficiency of any of these materials as tissue-conditioning agents. When the present results are considered along with those obtained in an earlier study (Part I), the following general conclusions can be made: 1. Coe-Comfort should exhibit the best tissue-conditioning characteristics of the materials tested. 2. F.I.T.T. should perform as the best functional impression material. 3. Lynal is distinctly different from the other two materials in its mechanical properties. Its much greater stiffness coupled with much lower plasticity precludes a prediction of its relative clinical efficacy.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Transcutaneous electrical nerve stimulation was applied in the pain management of a patient with Guillain-Barré Syndrome. As subjectively reported by the patient, her back and lower extremity pain was significantly decreased although her foot paresthesia was not decreased. The program was continued for an 11-day period because TENS was considered a valuable adjunct for the patient's comfort. Transcutaneous electrical nerve stimulation is a valuable addition to our repertoire of available physical therapy modalities. We hope that as clinical experience with TENS increases, fellow clinicians will volunteer the experiences of their endeavors.
Impressions of a laboratory model of an edentulous ridge were made with three commercial tissue conditioners (FITT, Hydro-Cast and Coe-Comfort). Combinations of undercut dimensions and tray relief were tested by using three different sized trays with each tissue conditioner. Greater tray relief increased the accuracy of all materials tested; increasing ageing time from 7 to 24 h resulted in little change of accuracy of the stone models poured from the impressions taken.
Permanent deformation, strain in compression, flow, dimensional stability, reproduction of detail and gypsum compatibility of three commercial tissue conditioners (Coe-Comfort, FITT and Hydro-cast) and one polysulphide base Type I impression material (Coe-flex) were measured according to ADA Specification No. 19. Although the tissue conditioners generally exhibited higher deformations and lower gypsum compatibility than specified by ADA Specification No. 19, the materials can, in all probability, be considered adequate for the present. It would appear that the development of international standards for tissue conditioners and functional impression materials is badly needed.
Since their discovery more than 40 years ago, PGs have been shown to be present in many tissues. The 10 members of this family (PGA-PGI and TxA) that have been identified to date have been noted to have a wide variety of pharmacologic actions. Frequently, the actions of one PG are in direct opposition to those of another. This has led to the theory that PGs play an important role in maintaining homeostasis in many organ systems. Evidence accumulated indicates a major role for PGs in the regulation of blood pressure, the autonomic nervous system, blood flow and platelet aggregation. This is in addition to specific actions on other tissues such as the CNS and reproductive system. A summary of PG actions in humans is contained in Table 1. Unfortunately, the PGs have not been as useful therapeutically as originally hoped. Currently, they are being used to induce labor and to maintain the patency of the PDA. However, they still hold much promise and with the development of synthetic analogues and specific synthesis inhibitors, they should live up to this promise in the future.