Interface pressure sensor for IVRA and other biomedical applications.

The fabrication and testing of a minimally intrusive (2 mm high, 10 mm diameter) biomedical interface pressure sensor are described. Such sensors are needed for the implementation of improved safety features in the next generation of automated intravenous regional anaesthesia (IVRA) systems. The sensor utilizes a structured elastomer as a deflection element sandwiched between the plates of a parallel plate capacitor device. Simple mechanical modifications allow sensitivity and zero offset adjustment. The sensor is housed in a package machined from an engineering polymer. The device is easily calibrated using either a bench-top or an on-body calibration procedure. The device is particularly sensitive to cuff artefacts arising from variations in cuff-wrap tightness and folding of the cuff. As such, it offers some promise for detecting potential hazard conditions which can occur during conventional IVRA procedures. For the purpose of unit conversion, 1 Pa = 1 N/m2, 1 MPA = 1 N/mm2 and 40 kPa approximately equal to 300 mmHg.

Anesthesia, Intravenous↗

Unanticipated variations between expected and delivered pneumatic compression therapy after elective hip surgery: a possible source of variation in reported patient outcomes.

The differences between the pneumatic compression thromboprophylaxis delivered after elective total hip arthroplasties and that was expected were quantified before (49 patients) and after a concerted nursing education program (30 patients) that was designed to ensure maximum compliance and to verify the correct application of the devices. The expected therapy was not delivered to any of the patients monitored. Therapy was delivered only an average of 77.8% of the time during the expected treatment periods. During 99.9% of the expected therapy times, values of key outcomes-related parameters of the therapy delivered to the patients varied by >10% from expected values. These variations were not reduced significantly by medical and nursing education. This variation may be a significant confounding factor in comparatively evaluating thromboembolic disease outcome reports.

Adult↗

A North American survey of intravenous regional anesthesia.

UNLABELLED: One thousand questionnaires concerning the techniques and complications of intravenous regional anesthesia (IVRA) were sent to 900 American and 100 Canadian anesthesiologists. Of the 321 respondents, 86% perform IVRA regularly. A wide variation in device-related and clinical aspects was found, ranging from acceptable to falling outside published guidelines. Anesthesiologists perform a median of four upper-limb IVR procedures per month, most often using 50 mL of lidocaine 0.5% at tourniquet pressures of 250 mm Hg or 100 mm Hg greater than the systolic blood pressure. Forearm, thigh, and calf IVRA are occasionally used. Complications, reported infrequently in the literature, were reported by respondents, including mistaken deflation of the cuff; dysphoria, dizziness, or facial tingling; seizures; cardiac arrests; and deaths. Although there was no correlation between complications and deviation from traditional practice, we recommend that IVRA be performed following recognized protocols by anesthesiologists who are familiar with the technique and trained to treat its potential complications. We recommend a protocol for IVRA. IMPLICATIONS: Intravenous regional anesthesia is a widely used anesthetic technique. A survey of 321 American and Canadian anesthesiologists indicates a wide variation in technique. Despite no correlation between complications and technique, the authors recommend that recognized protocols be used for this technique.

Adult↗

Occlusion of arterial flow in the extremities at subsystolic pressures through the use of wide tourniquet cuffs.

Tourniquet-induced peripheral neuropathy is at least partially attributable to excessive forces applied to the nerves beneath cuffs inflated to high pressures. Lowering the inflation pressure to the minimum necessary to obtain an effective arrest of blood flow distal to the tourniquet cuff should increase the safety of these systems. Tourniquet cuffs with widths varying from 4.5 cm to 80 cm were applied to the upper and lower extremities of 34 healthy, normotensive volunteers. Occlusion pressure for the arterial system under study was estimated by determining that level of cuff inflation at which the distal pulse became detectable by ultrasonic flowmetry. The occlusion pressure was inversely proportional to the ratio of tourniquet cuff width to limb circumference and was in the subsystolic range at a cuff width to limb circumference ratio above 0.5. Wide tourniquet cuffs can achieve an effective arrest of the regional arterial circulation at subsystolic pressures of inflation. Wide cuffs may reduce the risk of tourniquet-induced injury to underlying soft tissues by lowering the inflation pressure required to secure a bloodless field.

Arm↗

Perineural pressures under the pneumatic tourniquet in the upper extremity.

The literature indicates that tourniquet-induced neurological injuries are relatively common and frequently occur at a subclinical level. In order to evaluate the pressure transmitted to the major peripheral nerves of the arm by an externally applied pneumatic tourniquet, a fully implantable biomedical pressure transducer was placed adjacent the radial, median and ulnar nerves in six cadaver upper extremities of average dimensions. This sensor allowed accurate, reproducible measurements of perineural pressures without requiring significant disruption of the normal anatomical structures of the test limb for its installation. At levels of tourniquet cuff inflation which are commonly used in clinical practice, there was little or no decrease in the pressure detected in the perineural regions over that applied to the surface of the limb. In addition, there was a steep gradient of perineural pressure between locations beneath the edge of the cuff and those under its midpoint. This was most marked at the highest levels of tourniquet inflation. At presently accepted levels of inflation, pneumatic tourniquet cuffs transmit high pressures to the peripheral nerves without any significant attenuation by the intervening soft tissues. The distribution of these forces is one which may subject the underlying nerves to deleterious shear forces, especially at higher levels of inflation.

Arm↗

Detection of interruptions in the breathing gas of ventilated anaesthetized patients.

Interruption of the breathing gas to a ventilated anaesthetized patient due to accidental disconnection or anaesthesia system malfunction may have serious consequences if not detected quickly. A series of tests which covers the range of foreseeable mechanical problems was developed and used to test the performance of three breathing gas interruption monitors, two commercially available and one developed at Vancouver General Hospital. The tests were designed to evaluate the performance of monitors as installed on anaesthesia systems under a variety of failure conditions, including endotracheal tube disconnection with and without occlusion of the opening, kinks in the inspiratory and fresh gas hoses, disconnection of the fresh gas hose, leaks in the breathing circuit, excessive high or low pressure in the scavenging circuit, continuing high breathing circuit pressure, and kinks in the circuit pressure sensing hose. Ability to detect both significant changes in ventilation variables and faults existing at initiation of ventilation were also tested over a representative range of ventilator and patient variables using circle, coaxial and paediatric circuits. Only complete endotracheal tube disconnections with no obstruction of the opening were reliably detected by all three monitors. A commercial monitor with a single fixed-threshold alarm level also detected fresh gas interruptions in circle and adult coaxial circuits, but failed to alarm in response to any other fault condition. A monitor with selectable pressure thresholds and high, low, and continuing pressure limits detected just under half of the fault conditions. A microprocessor-based monitor developed at Vancouver General Hospital detected and correctly identified roughly 80 per cent of the faults. The series of tests forms the basis for a Canadian Standards Association Preliminary Standard (Z168.10) and will allow hospitals to test the performance of breathing gas interruption monitors in use in their institutions. Comments on the test series are solicited.

Anesthesia↗

New finger cuffs for use with digital tourniquets.

The advent of tourniquets employing digital technology has led to significant improvements in the safety and accuracy of surgical procedures performed with an occlusive cuff applied proximally on a limb. This article describes the evaluation of new cuffs used on fingers that may permit significantly lower pressures to be more safely and consistently employed. Our experimental studies would suggest that finger occlusion pressure is a function of cuff design, cuff width, finger circumference, and systolic blood pressure.

Adult↗

A study of anaesthesia depth by power spectral analysis of the electroencephalogram (EEG).

The feasibility of using computer-based EEG spectral analysis to monitor the level of anaesthesia during nitrous oxide-alphaprodine anaesthesia has been established by this study. At present, this system is capable of estimating the level of anaesthesia correctly from 55 per cent to 80 per cent of the time. There are several possible clinical applications of such a monitoring system during anaesthesia. It provides a continuous estimation of the depth of anaesthesia, without requiring any special EEG training on the part of the anaesthetist. This system can also be of particular benefit during anaesthesia for critically ill patients, or in specific cases, as in neurosurgery and caesarian section when there may be periods of time when the gross clinical evaluation of depth of anaesthesia may not be precise or reliable and yet it is imperative not to deepen the anaesthesia unnecessarily. In such instances it appears that a monitoring system such as we have developed could provide valuable indication of the depth of anaesthesia. Other potential applications might be in the training of students in the clinical assessment of patients during anaesthesia and in the study of new anaesthetic agents.

Adult↗