Improved pulmonary nodule detection with scanning equalization radiography.

The potential for improved pulmonary nodule detection with scanning equalization radiography (SER) was evaluated by means of observer performance testing during the interpretation of posteroanterior conventional radiographs and SER images of an anthropomorphic chest phantom with simulated nodules. A test set of 200 conventional and 200 SER radiographs of phantoms containing either one nodule or none was interpreted by four radiologists attempting to detect a nodule and indicate a confidence value. Their ability to detect nodules positioned over the lung was slightly improved with SER compared with conventional radiography (sensitivity, .56 vs .70); for nodules over the mediastinum or diaphragmatic areas, it was much improved (sensitivity, .29 vs .64). The results were also analyzed with receiver-operating characteristic methods, which revealed a significant improvement in lesion detect-ability over the thicker body parts with SER images. The capability of equalized chest radiographs to provide improved lesion detectability suggests that SER may set a new standard for film-based chest radiography and have a large clinical application.

Humans↗

Ethanol effects on synaptic glutamate receptor function and on membrane lipid organization.

The enhancement of L-glutamic acid binding activity of brain synaptic membranes by low concentrations of ethanol (less than 50 mM) and the decrease in binding at high concentrations (greater than 100 mM) was not due to a direct action by ethanol on the glutamate binding protein. Biphasic effects of ethanol on membrane protein complexes such as the glutamate binding sites might be the result of biphasic changes in membrane lipid organization. Low ethanol concentrations (0.1-4.0 mM) were shown to decrease fatty acid chain motion detected by the EPR probe 5-doxyl stearic acid, whereas high concentrations (greater than 400 mM) increased lipid motion in egg phosphatidylcholine liposomes. The function of the L-glutamate receptor-ion channel complex in the presence of ethanol was also determined by measuring the changes in thiocyanate (SCN-) influx brought about by L-glutamate or ethanol. A low concentration of ethanol (9.4 mM) diminished the L-glutamate-induced depolarization of synaptic membranes, while a high concentration (93.7 mM) increased the passive SCN-influx and produced a transient overshoot in glutamate-stimulated SCN-flux.

Animals↗

Ethanol effects on synaptic glutamate receptors and on liposomal membrane structure.

Exposure of synaptic plasma membranes to 50 mM ethanol in vitro brought about a 3.5 degrees C decrease in the transition temperature of the high affinity glutamate binding process in these membranes. Ethanol had no effect on the energy of activation of glutamate binding below the transition temperature but decreased the energy of activation above the transition temperature. Electron paramagnetic resonance (EPR) studies of lipid organization of egg lecithin and bovine brain phospholipid liposomes indicated that ethanol at low concentrations (0.04--2 mM) caused small increases in the rigidity of the membrane near the surface. At higher concentrations (0.04--2 M) ethanol brought about increasing fluidization of both the surface and inner areas of the bilayer. Even at 4 mM concentration ethanol enhanced the ordered to fluid state transition of liposome membranes as shown by a 5.2 degrees C and 1.9 degrees C decrease in the transition temperatures of the membrane determined with the cholestane EPR probe.

Animals↗

Parallel-plate ionization chamber response in cobalt-60 irradiated transition zones.

The authors study the acceptance of a Capintec parallel-plate ionization chamber. The Capintec chamber is used for dose measurements in a lead and polystyrene slab phantom irradiated with cobalt-60 gamma rays. The authors define an enhancement ratio to quantify the dose measurements. The enhancement ratio equals the ratio of dose measured with the lead slab present to dose measured under equilibrium conditions in polystyrene at equal primary beam attenuation. The measured enhancement ratio at the exit side of the lead/polystyrene interface is 25% lower than the Monte Carlo predicted enhancement ratio. The authors propose that geometric acceptance limitations of the Capintec chamber to large-angle, low-energy electrons are the cause for this difference. A Monte Carlo simulation of the Capintec chamber acceptance confirms the hypothesis.

Cobalt Radioisotopes↗