PubMed Health⌕ Search

Biomedical subjects

J A Penny

Publications and source records attributed to J A Penny.

8 recordsLinked to original sources

Birth weight and 24-hour ambulatory blood pressure in nonproteinuric hypertensive pregnancy.

OBJECTIVE: The aim of this study was to examine the relationship between maternal ambulatory blood pressure monitor measurements during pregnancy and birth weight in a population of women considered to have hypertension according to conventional antenatal clinic measurement. STUDY DESIGN: A prospective observational study was carried out within the obstetric departments of Leicester Royal Infirmary and Queen Charlotte's Hospital. A total of 237 women were found to have hypertension (blood pressure >/=140/90 mm Hg) without significant proteinuria during examination in the antenatal assessment area. Sequential-day unit blood pressure recordings and a 24-hour automated ambulatory blood pressure recording were performed, and the results were compared with the principal outcome measure of birth weight. RESULTS: A significant inverse association (gradient, -13.5; 95% confidence interval -23.4 to -3.6) was found between daytime ambulatory diastolic blood pressure measurement and birth weight. An increase of 5 mm Hg in daytime mean diastolic blood pressure was associated with a fall in birth weight of 68.5 g. This association remained after adjustment for potential confounders that included maternal age, maternal weight, smoking status, ethnicity, and gestational age at delivery. No such association was found between obstetric day unit assessment of blood pressure and birth weight. CONCLUSION: There is a significant association between blood pressure and birth weight in nonproteinuric hypertensive pregnancies. The best predictor of this association is the daytime mean ambulatory diastolic blood pressure measurement. This is further evidence that maternal blood pressure may be an important confounding and potentially genetic variable in the association between birth weight and subsequent adult hypertension.

Adult↗

A comparison of hemodynamic data derived by pulmonary artery flotation catheter and the esophageal Doppler monitor in preeclampsia.

OBJECTIVE: This study was undertaken to compare hemodynamic data derived with the esophageal Doppler monitor against those obtained with a pulmonary artery flotation catheter in women with complicated preeclampsia. STUDY DESIGN: Seventeen women with severe preeclampsia who had a pulmonary artery flotation catheter placed for clinical indications also had an esophageal Doppler monitor inserted. Hemodynamic data were recorded on 2 occasions separated by several hours with both the pulmonary artery flotation catheter and the esophageal Doppler monitor simultaneously. RESULTS: The esophageal Doppler monitor underestimated cardiac output by 36% +/- 14% (mean +/- SD). The esophageal Doppler monitor accurately estimated cardiac output in 3 women >40 years old, whereas in the remaining women (all <35 years old) the esophageal Doppler monitor underestimated cardiac output by 38% +/- 11%. The esophageal Doppler monitor accurately reflected changes in cardiac output with time when compared with the pulmonary artery flotation catheter. CONCLUSION: In women with preeclampsia the esophageal Doppler monitor consistently underestimated cardiac output by approximately 40%. It is not known whether the apparent increase in accuracy among the women >40 years old arose by chance or reflected a real improvement in performance. The esophageal Doppler monitor accurately reflected the direction and magnitude of the changes in cardiac output with time.

Adult↗

The relative accuracy of sequential same-arm and simultaneous opposite-arm measurements for the intra-arterial validation of blood pressure monitors.

OBJECTIVE: To compare the results of simultaneous opposite-arm and sequential same-arm intra-arterial validation of automated blood pressure monitors. DESIGN: Intra-arterial blood pressure measurements were compared with blood pressure measurements obtained using conventional sphygmomanometry and two automated blood pressure monitors (the Dinamap XL and the SpaceLabs Scout) using a methodology based on the protocol published by the Association for the Advancement of Medical Instrumentation (AAMI) for the intra-arterial validation of automated monitors. METHODS: Thirteen women with radial arterial lines were recruited from the obstetric intensive care unit at Groote Schuur Hospital, Cape Town. For each woman, intra-arterial blood pressure measurements were compared with those obtained by mercury sphygmomanometry and by using the two automated blood pressure monitors with both a sequential same-arm protocol and a simultaneous opposite-arm protocol. The mean and SD of the differences was calculated for each protocol and the results were compared using Student s t test. RESULTS: The differences between the 'means of the differences' for these two protocols never differed by more than 2 mmHg. For individuals the differences between data obtained using the two methodologies were up to 32 mmHg for mercury sphygmomanometry and 18 mmHg for the automated monitors. The differences between the SD of the differences were all less than 3 mmHg except for that of systolic blood pressure obtained by mercury sphygmomanometry, which was 7 mmHg CONCLUSIONS: The results of this study show that a sequential same-arm and a simultaneous opposite-arm comparison of intra-arterial and indirect blood pressure measurements yield similar results.

Arteries↗

Automated, ambulatory, or conventional blood pressure measurement in pregnancy: which is the better predictor of severe hypertension?

OBJECTIVES: Our purpose was to investigate the benefit, if any, of automated blood pressure monitoring over obstetric day unit conventional blood pressure measurement in the assessment of hypertensive pregnancies. STUDY DESIGN: A prospective, observational study was carried out in two large teaching hospitals. Three hundred and forty-eight women with a confirmed clinic blood pressure of at least 140/90 mm Hg were recruited. Conventional blood pressure measurements (< or =5) were obtained on the day unit and simultaneously an ambulatory blood pressure monitor was applied for 24 hours. The predictive ability of day unit assessment (blood pressure > 140/90 mm Hg) and automated blood pressure monitoring (blood pressure > 130/85 mm Hg) was compared. Principal outcome measures included the occurrence of severe hypertension (> 160/110 mm Hg) and proteinuria (> 500 mg or 2+) within (a) 2 weeks and (b) the remainder of the pregnancy. Thompson's method was used to compare sensitivity and specificity of the day unit blood pressure and automated blood pressure monitoring. RESULTS: Three hundred and forty-eight women were recruited to the study. The comparison between automated blood pressure monitoring and conventional blood pressure measurement for both sensitivity and specificity for systolic and diastolic blood pressure revealed increased sensitivity and decreased specificity with automated blood pressure monitoring for all principal outcomes except development of proteinuria for systolic blood pressure. Sensitivity for the outcomes was increased with automated blood pressure monitoring by between 14% and 27% for systolic blood pressure and between 7% and 39% for diastolic blood pressure, with the greatest improvement seen for the development of severe hypertension within 2 weeks of assessment. CONCLUSIONS: In the assessment of hypertensive pregnancies, automated blood pressure measurement was a significantly better predictor (compared with conventional day unit assessment) for the development of severe hypertension within 2 weeks of assessment for both systolic and diastolic blood pressure.

Adult↗

Retroperitoneal malignancy masquerading as ureteric colic.

This study reviews 6 patients who were referred with severe loin pain radiating to the groin and in whom a presumptive diagnosis of ureteric colic was made. Of these, 3 patients were found to have carcinoma of the pancreas and the remaining 3 had retroperitoneal lymph node metastases. Retroperitoneal malignancies rarely present with loin pain, but this diagnosis should be considered in patients with long-standing loin pain in whom an obvious diagnosis is not apparent.

Adult↗