Effects of the combination of bimatoprost and latanoprost on intraocular pressure in primary open angle glaucoma: a randomised clinical trial.

AIMS: To evaluate the effect of the combination of bimatoprost and latanoprost on intraocular pressure (IOP) in primary open angle glaucoma (POAG). METHODS: An open label randomised clinical trial was conducted, which included 18 glaucomatous patients (36 eyes). In the first 4 weeks, latanoprost 0.005% was prescribed for both eyes of the patients and any other antiglaucoma medication was discontinued. In the next 4 weeks (phase 1), bimatoprost 0.03% was combined with latanoprost in one randomly assigned eye (case eye) of each patient. In the next 4 weeks (phase 2), bimatoprost was discontinued in the case eyes, while bimatoprost was substituted for latanoprost in the fellow eye (control eye). The IOP was measured at the end of the first 4 weeks (baseline measurement) and weekly during phases 1 and 2. RESULTS: In the case eyes, the mean IOP increased along the first phase (1.8 mm Hg; p = 0.006) when compared to baseline measurements. The IOP returned to previous values after discontinuation of bimatoprost in phase 2. In the control eyes, the mean IOP did not change throughout the study. CONCLUSION: The combination of bimatoprost and latanoprost in POAG increases the IOP and should not be considered as a therapeutic option.

Aged↗

Influence of keratometric readings on comparative intraocular pressure measurements with Goldmann, Tono-Pen, and noncontact tonometers.

PURPOSE: To evaluate the influence of keratometric measurements on the concordance of intraocular pressure (IOP) readings with three applanation tonometers. PATIENTS AND METHODS: The IOPs of 404 eyes of 202 patients from a general eye clinic were measured by Goldmann, Tono-Pen XL, and noncontact Nidek NT 2000 tonometers. Differences in the IOP measurements between Goldmann and the other two tonometers (deltaIOPG-TP and deltaIOPG-NCT) were analyzed in the overall group and within three subgroups based on keratometry measures: flatter, intermediate, and steeper corneas (quartiles as cut-off points). Regression analysis of deltaIOP and keratometry measures was also performed. Right and left eyes were analyzed separately. RESULTS: The IOP readings taken with the Goldmann tonometer were significantly higher than those taken with either of the other two tonometers within the overall study population. The deltaIOP within the three keratometric subgroups was not statistically significant except for deltaIOPG-TP in the right eyes. Regression analysis showed that keratometry and deltaIOPG-TP and deltaIOPG-NCT had a significant but very weak coefficient of correlation in the right eye, but not in the left. CONCLUSION: Corneal curvature within the normal range does not have a clinically significant influence on the concordance of IOP readings obtained with Goldmann and Tono-Pen or noncontact tonometers.

Adolescent↗

Aqueous humor dynamics in rats.

BACKGROUND: In order to determine normal outflow facility and aqueous humor production values in Lewis rats, we established methods of measuring aqueous humor dynamics in this animal. METHODS: Outflow facility was determined using anterior chamber infusion with constant pressure. Aqueous humor production was determined by a technique of dilution with FITC-albumin. RESULTS: The mean outflow facility was 0.044 +/- 0.01 microliter/min/mmHg. Rats weighing less than 300 g had lower values than did rats weighing more than 300 g (0.034 +/- 0.006 microliter/min/mmHg vs 0.050 +/- 0.015 microliter/min/mmHg, P = 0.009). The mean aqueous humor production was 0.350 +/- 0.110 microliter/min. The turnover rate of aqueous humor production per minute was 2.23%. CONCLUSIONS: Anterior chamber infusion with constant pressure and the FITC-albumin method allow measurement of the outflow facility and aqueous humor production in Lewis rats. These methods may be useful in assessing aqueous humor dynamics when rats are used as a glaucoma model.

Animals↗

Effects of intraoperative mitomycin-C on the function of Baerveldt glaucoma drainage implants in rabbits.

PURPOSE: The purpose of this study was to assess the effects of intraoperative mitomycin-C (MMC) on the function of Baerveldt glaucoma implants in rabbits. METHODS: Bilateral implantations of 200 mm2 Baerveldt drainage devices were performed in 30 normal albino rabbits. One eye, randomly selected, received intraoperative application of MMC at the site of the implant plate for 5 min, via a 6 x 4 x 2 mm cellulose sponge saturated with 0.5 mg/ml of MMC. The opposite eye served as a control. MMC-treated and control eyes (five animals each group) were compared for intraocular pressure (IOP), resistance to flow, flow rates through the implant and histopathological findings at 2, 4, 6, 12, and 24 weeks postoperatively. Resistance to flow and flow rates through the implants were studied after opening the cornea and connecting the drain tube to a micromanometric system. RESULTS: Preoperative IOP did not differ between groups. MMC-treated eyes had lower levels of IOP than did controls at all postoperative times. The differences in IOP were statistically significant up to 8 weeks postoperatively. Resistance to flow was lower in MMC-treated eyes at all times studied, but the differences were statistically significant only at the time points of 2, 4, and 6 weeks. Flow rates through the implant bleb were always higher in MMC-treated eyes, and statistically significant differences were seen at 2, 4, 6, and 24 weeks. Histopathologically, MMC-treated eyes had thinner implant capsules with delayed maturation and less inflammatory infiltrate. CONCLUSION: MMC causes lower IOP and higher perfusion rates through the implant capsule at 2, 4, and 6 weeks postoperatively. Wound dehiscence, bleb leaks, and extraocular muscle injury were observed only in MMC-treated eyes.

Administration, Topical↗

Cataract surgery after trabeculectomy.

BACKGROUND AND OBJECTIVE: To determine the effect of cataract surgery on glaucomatous eyes with good intraocular pressure (IOP) control after trabeculectomy. PATIENTS AND METHODS: Twenty-two eyes with functional blebs that underwent cataract extraction were retrospectively analyzed. RESULTS: The mean (+/- SD) preoperative IOP was 11.0 +/- 4.3 mm Hg. The mean (+/- SD) postoperative IOPs at 1, 2, 6, and 9 months were 15.5 +/- 4.9, 12.6 +/- 4.7, 14.6 +/- 5.6, and 19.0 +/- 7.9 mm Hg, respectively. At each interval except for the second month, the mean IOP was statistically significantly higher than the preoperative value (P = .0003, .24, .02, and .0009, respectively). The total number of medications was also higher (3 preoperatively versus 27 postoperatively). The interval between the two surgeries had no influence on IOP control. Intraoperative complications during cataract surgery, particularly vitreous loss, were associated with poor IOP control. Phacoemulsification had less of an effect on the postoperative IOP control than did extracapsular cataract extraction. CONCLUSIONS: Eyes with previous successful trabeculectomies had higher IOPs and required more medications after subsequent cataract surgeries.

Aged↗

In vitro and in vivo flow characteristics of glaucoma drainage implants.

PURPOSE: To determine pressure-flow characteristics at physiologic flow rates in vitro and in vivo in rabbits for Ahmed, Baerveldt, Krupin disk, and OptiMed glaucoma implants. The Molteno dual-chamber implant also was evaluated in vivo only. METHODS: Five samples of each glaucoma implant were studied. Baerveldt implants were ligated partially for in vitro testing. Opening and closing pressures in air or after immersion in balanced salt solution or plasma were evaluated for the valved devices (Ahmed and Krupin). Pressures were measured in vitro and in vivo in normal rabbits at flow rates preset at between 2 and 25 microliters/minute after the tubes were connected to a closed manometric system. In vivo measurements were made 24 hours after implantation. Resistance to flow was calculated using Poiseuille's equation after at least three separate flow rate readings. RESULTS: In air, the Ahmed and Krupin valves had opening pressures of 9.2 +/- 3.4 and 7.2 +/- 0.6 mmHg and closing pressures of 5.2 +/- 0.9 and 3.9 +/- 1 mmHg, respectively. Neither opening nor closing pressures could be determined when Ahmed and Krupin valves were immersed. In vitro, the Ahmed and OptiMed devices had higher pressures than did other devices at a 2-microliters/minute flow rate of balanced salt solution. During perfusion with plasma, only the OptiMed device maintained higher pressures than with balanced salt. With all devices, pressures fell rapidly to zero after flow was stopped. The OptiMed device demonstrated the highest resistance values. In vivo, the Ahmed device provided pressures of 7.5 +/- 0.8 mmHg and the OptiMed device gave pressures of 19.6 +/- 5.6 mmHg at a 2-microliters/minute flow rate. After 15 minutes of flow shutdown, the OptiMed implant maintained pressures of 7.1 +/- 1.1 mmHg. The Baerveldt (nonligatured), Krupin, and Molteno dual-chamber implants had similar resistances and pressures in vivo. Pressures with all devices in vivo fell rapidly to zero after conjunctival wound disruption. CONCLUSION: Neither the Ahmed nor Krupin devices had demonstrable opening or closing pressures when tested in vitro immersed in balanced salt solution or plasma. With all devices, pressures were higher in vivo than in vitro due to tissue-induced resistance around the explant. Both Ahmed and Krupin valves functioned as flow-restricting devices at the flow rates studied, but did not close after initial perfusion with fluid.

Animals↗

Mitomycin-C concentration in human aqueous humour following trabeculectomy.

The aim of the study was to determine mitomycin-C (MMC) concentrations in human aqueous humour during trabeculectomy and to correlate anterior chamber concentrations with method of application. MMC was applied intra-operatively by saturating sponges, ranging in size from 2 x 2 x 5 mm to 2 x 4 x 10 mm on dry cut, with 0.5 mg/ml MMC during trabeculectomy for 3-5 minutes. Applications to episclera were made in 18 cases and to the scleral bed after scleral flap dissection in 9 cases. Aqueous samples were collected by paracentesis with a 30 gauge needle 2-7 minutes after removal of sponge and external irrigation. Aqueous MMC concentrations were determined by high-performance liquid chromatography. Aqueous MMC concentration in 27 samples ranged from below minimum detectable concentration (less than 5 ng/ml) to 120.8 ng/ml. Mean aqueous drug levels obtained when the applications were to the scleral bed were 35.65 +/- 39.17 ng/ml (range 5-120.8 ng/ml). Applications on episclera gave mean aqueous concentrations of 4.98 +/- 9.11 ng/ml (range 0-33.3 ng/ml). The difference was statistically significant (p = 0.004). There were no correlations between sponge size, time of MMC exposure and aqueous MMC level. In conclusion, MMC is detectable in aqueous humour within minutes of external application and the aqueous concentration level is higher if the application is in the scleral bed than on the episclera. Toxicity of the drug at this concentration range for corneal endothelial cells needs further investigation via in vitro and clinical studies.

Adolescent↗

Pseudo-Brown's syndrome as a complication of glaucoma drainage implant surgery.

Two cases of pseudo-Brown's syndrome occurring after superior nasal implantation of glaucoma filtering devices are described. We hypothesize that this restriction in ocular motility was due to the mechanical effects of large filtering blebs or increased inflammation and scar formation in the superior nasal quadrant. Serial ultrasound examinations of our patients demonstrated development of a large bleb, coincidental with the disturbance in motility. Because of the risk of strabismus, we no longer recommend placing large implant devices in the superior nasal quadrant in eyes that have good vision.

Aged↗

[Anisocoria in the chronic phase of Chagas' disease].

To compare the frequency of anisocoria in patients with chronic Chagas' disease a prospective double-blind study was done in 131 patients with positive serology for Chagas' disease and 138 negative, at Mambaí (GO-Brazil), which is an endemic area for Chagas' disease. To detect anisocoria, pupillometry was done with a millimetric ruler. Anisocoria was seen in 10(7.6%) patients with Chagas' disease and in 3(2.1%) normal subjects. The chi-square test showed statistical significance at level of 5%. Chagas' disease must be included among the causes of anisocoria.

Adult↗

[The pupil in the chronic phase of Chagas disease and the reaction to pilocarpine and phenylephrine].

To develop a method to analyse pupillary disturbances in patients with chronic Chagas disease in an endemic area, ten chagasic and ten normal subjects were matched according to sex, age and race. Pupillary diameter and area were determined using projection and topography techniques and compared between groups. Both pupils were visualised simultaneously. In each case three photographs were taken under standardised illumination. The first photo was obtained without medication, the second, 30 minutes after instillation of 0,1% pilocarpine and the last 30 minutes after instillation of 3% phenylephrine (60 minutes after pilocarpine). Pupils of chagasic patients had a statistically significant greater initial diameter and area, irregularity of the pupil border, greater percentual reduction in diameter and area after pilocarpine 0.1% and greater percentual increase in diameter and area after 3% phenylephrine eyedrops. The method developed for this study was considered satisfactory. The results suggest ocular autonomic nervous system disturbances in chagasic patients.

Chagas Disease↗

Trabeculectomy with mitomycin C in glaucoma associated with uveitis.

Twenty-four trabeculectomies performed in 24 patients for control of uveitic glaucoma were retrospectively evaluated to analyze the effect of intraoperative application of mitomycin C (MMC) on the short-term outcome of trabeculectomy for glaucoma associated with uveitis. Success rates, postoperative levels of intraocular pressure (IOP), and complications were studied. After a mean follow up of 9.87 months (range, 3 to 27 months), 18 eyes (75%) achieved an IOP of 21 mm Hg or less without antiglaucoma medications. The same IOP level with one antiglaucoma medication was achieved in four eyes (16.6%). Statistical analysis demonstrated a significant reduction in IOP postoperatively during the period studied (P = .0001). Complications observed included exacerbation of the uveitis (12.5%), choroidal detachment (12.5%), hypotony (8.3%), postoperative shallow anterior chamber (4.2%), wound leak (4.2%), hyphema (4.2%), and macular edema (4.2%). The results of this retrospective and uncontrolled study suggest that intraoperative application of MMC may be a good option for enhancement of short-term trabeculectomy success rates in cases of uveitic glaucoma.

Adolescent↗