Staging prostate cancer with MR imaging: a combined radiologist-computer system.

PURPOSE: To test the accuracy of a combined radiologist-computer system in the diagnosis with magnetic resonance (MR) imaging of cancer of the prostate gland. MATERIALS AND METHODS: The combined system was developed and tested by four specialists in prostate MR imaging and five radiologists expert in body MR imaging. Each group read MR images obtained in 100 proved cases of prostate cancer. The images were obtained from two sources, and all were obtained with an endorectal surface coil. Prostate MR specialists ranked imaging features of cases to develop a checklist for image interpretation. Features with greatest diagnostic value were incorporated in the combined system. Accuracy measures were derived from the area index of the receiver operating characteristic curve for the combined system and compared with those of radiologists working alone. RESULTS: Body MR radiologists had a mean baseline accuracy of 0.67; mean accuracy of their combined system was 0.80. The prostate MR specialists, when they rated the features in each case, had a mean accuracy of 0.81; the accuracy of their combined system was 0.87. CONCLUSIONS: A combined radiologist-computer system substantially improved accuracy of body MR radiologists in the diagnosis of prostate cancer. High levels of accuracy were also achieved by the system with prostate MR specialists.

Diagnosis, Computer-Assisted↗

Prostate cancer: relative effects of demographic, clinical, histologic, and MR imaging variables on the accuracy of staging.

PURPOSE: To determine the effects on the accuracy of staging prostate gland cancer of diagnostic prediction rules based on demographic, clinical, histologic, and magnetic resonance (MR) image variables. MATERIALS AND METHODS: A total of 200 cases from four medical centers were evaluated by nine radiologists experienced in MR imaging. The accuracies of the four diagnostic variables (age, prostate specific antigen level, Gleason tumor grade, and MR imaging findings) were measured, both singly and combined in a particular sequence, by calculating the area index of the receiver operating characteristic curve. RESULTS: The accuracy of staging with single variables (age, 0.58; prostate specific antigen level, 0.74; Gleason grade 0.73, MR image findings, 0.74) increased as the variables were optimally merged. The first two variables combined to yield an accuracy of 0.74; the first three combined to yield an accuracy of 0.81; and all four variables resulted in an accuracy of 0.86. In a clinically important subset of 69 cases for which antigen level and Gleason grade together were inconclusive for the purposes of staging, the addition of MR imaging findings resulted in an increase in accuracy from 0.55 to 0.73. CONCLUSION: Optimal merging of diagnostic test results yields an improvement in the accuracy of prostate cancer staging.

Age Factors↗

The science of choosing the right decision threshold in high-stakes diagnostics.

Many diagnostic tasks require that a threshold be set to convert evidence that is a matter of degree into a positive or negative decision. Although techniques of decision analysis used in psychology help one select the particular threshold that is appropriate to a given situation and purpose, just the concept of adjusting the threshold to the situation is not appreciated in many important practical arenas. Testing for the human immunodeficiency virus (HIV) and for dangerous flaws in aircraft structures are used here as illustrations. This article briefly reviews the relevant techniques and develops those two examples with data. It suggests that use of the decision techniques could substantially benefit individuals and society and asks how that use might be facilitated.

Aircraft↗

Reading and decision aids for improved accuracy and standardization of mammographic diagnosis.

Image-reading and decision aids were designed to improve the accuracy of mammogram interpretation. The reading aid was a list of diagnostic radiographic features and scales for quantification of each feature. The decision aid, a computer program, converted the reader's scaled values, weighted for predictive power, into an advisory estimate of the probability of malignancy. The features were identified and their importance was assigned in four steps: (a) interviews of five expert readers to establish an initial set of features, (b) perceptual tests to refine the feature set, (c) a consensus meeting to refine this set and establish nomenclature and scales, and (d) the expert's scaling of each feature in a set of 150 mammograms. Those scaled judgments were analyzed to provide the final list of features and their relative importance and to program the computer decision aid. To test the enhancement effect, six other radiologists interpreted a different set of mammograms without, and later with, the two aids. Receiver operating characteristic analysis showed a gain of approximately 0.05 in sensitivity or specificity when the other value remained at 0.85. In a subset of the more difficult cases, the enhancement effect was approximately 0.15 in either sensitivity or specificity.

Humans↗

Measuring the accuracy of diagnostic systems.

Diagnostic systems of several kinds are used to distinguish between two classes of events, essentially "signals" and "noise". For them, analysis in terms of the "relative operating characteristic" of signal detection theory provides a precise and valid measure of diagnostic accuracy. It is the only measure available that is uninfluenced by decision biases and prior probabilities, and it places the performances of diverse systems on a common, easily interpreted scale. Representative values of this measure are reported here for systems in medical imaging, materials testing, weather forecasting, information retrieval, polygraph lie detection, and aptitude testing. Though the measure itself is sound, the values obtained from tests of diagnostic systems often require qualification because the test data on which they are based are of unsure quality. A common set of problems in testing is faced in all fields. How well these problems are handled, or can be handled in a given field, determines the degree of confidence that can be placed in a measured value of accuracy. Some fields fare much better than others.

Diagnosis↗

Enhanced interpretation of diagnostic images.

In radiology, as in various other fields, observers study images to detect and diagnose underlying conditions. They make assessments of several image features and merge them into an overall decision. Demonstration is given here, in the context of mammography, that objective aids to this interpretative process can substantially improve accuracy, even for sophisticated and motivated radiologists. The aids are a checklist that solicits explicit, quantitative, systematic assessments of the important features of an image and a computer program that merges those assessments with optimal weights. The computer issues estimates of the likelihoods that specified conditions are present (in this study, the likelihood that a localized abnormality is malignant), and the radiologist benefits from taking those estimates as guidance.

Female↗

Patient-oriented performance measures of diagnostic tests. 2. Assignment potential and assignment strength.

Assignment Potential (AP) is a performance measure of a diagnostic test, characterizing the chance that, as a consequence of performing the test, the probability of disease will exceed a decision threshold, thereby permitting a management action to be taken. Another performance measure, Assignment Strength (AS) characterizes the average extent to which a decision threshold will be exceeded when the post-test probability of disease does exceed the threshold. Both AP and AS are functions of prior probability of disease and decision threshold, and can be represented as two-dimensional contour maps indicating their behavior throughout the entire probability and threshold space. AP and AS can be determined for both discrete-valued tests and tests with continuous spectra of results. The contour map displays facilitate determination of the values of these measures at any prior probability and threshold, as well as visual sensitivity analysis for ranges of prior probability and/or threshold. AP and AS may be useful to the clinician in prospective evaluation of a diagnostic test in situations where formal decision analysis is not feasible.

Diagnosis↗

Assessment of diagnostic technologies.

A general protocol for rigorous evaluation of diagnostic systems in medicine was applied successfully in a comparative study of two radiologic techniques. Accuracies of computed tomography and radionuclide scanning in detecting, localizing, and diagnosing brain lesions were assessed with a sample of patients in whom tumor had been suspected. The principal means of analysis was the "relative operating characteristic," which is unique in providing a measure of accuracy that is largely independent of decision biases. Computed tomography was found to be substantially more accurate than radionuclide scanning.

Brain↗

Attention.

Explore the source record for details and available documents.

Attention↗