PubMed Health⌕ Search

Biomedical subjects

J A Tkach

Publications and source records attributed to J A Tkach.

25 records · Page 2Linked to original sources

Fast spin-echo imaging of the knee: factors influencing contrast.

Conventional T2-weighted spin-echo magnetic resonance imaging of the knee requires a long TR. Fast spin-echo (FSE) imaging can improve acquisition efficiency severalfold by collecting multiple lines of k space for each TR. Compromises in resolution, section coverage, and contrast inevitably result. The authors examined the compromises encountered in FSE imaging of the knee and discuss the variations in image contrast and resolution due to choices of sequence parameters. For short TR/TE knee imaging, FSE does not appear to offer any advantages, since the increased collection efficiency for one section reduces the available number of sections, so that the total imaging time for a given number of sections remains constant relative to conventional spin-echo imaging. For T2-weighted images, considerable time can be saved and comparable quality images can be obtained. This saved time can be usefully spent on increasing both the resolution of the image and its signal-to-noise ratio, while still reducing total acquisition time by a factor of two. The preferred FSE T2-weighted images were acquired with a TR of 4,500 msec, TE of 120 msec, and eight echoes. The available number of sections is compromised, and the sequence remains sensitive to flow artifacts; however, the FSE sequence appears to be promising for knee imaging.

Humans↗

Separation of fat and water in fast spin-echo MR imaging with the three-point Dixon technique.

A method for suppressing fat in fast spin-echo imaging with the three-point Dixon technique is described. The method differs from the three-point Dixon method used in conventional spin-echo imaging in that the readout gradient instead of a radio-frequency pulse is shifted. This method preserves the Carr-Purcell-Meiboom-Gill nature of the fast spin-echo sequence and hence is less sensitive to magnetic field inhomogeneities and resonance frequency mistuning. As in the original three-point Dixon technique used in conventional spin-echo imaging, three acquisitions are required to estimate the field inhomogeneity and completely separate fat and water. The extra time required is not excessive considering that the fast spin-echo method is frequently applied with multiple signal acquisition. Also, this technique achieves an expected signal-to-noise ratio comparable to 2.67 signal acquisitions, which is approximately 94% of the signal-to-noise ratio obtained with three signal acquisitions. The method is demonstrated with applications to phantoms and a human volunteer.

Adipose Tissue↗

A comparison of fast spin echo and gradient field echo sequences.

Optimal angle, fast repeat time, gradient field echo imaging techniques such as FISP (Fast Imaging with Steady Precession) and FLASH (Fast Low Angle Shot) often fail to discriminate disease from healthy tissue for two main reasons. First, T1 and T2 of the affected tissue may increase such that the ratio of T1 to T2 remains nearly unchanged, hence there is no contrast change with FISP. Second, T2 weighted gradient field echo images suffer severely from T2* signal and resolution loss leading to a reduction in C/N. Although FLASH imaging with two separate angles can, in principle, extract the longer T1 tumors, contrast is often not good. To overcome the inhomogeneity and contrast problems, we have implemented a FAst optimal angle spin-echo sequence with a short TE(FATE). For the first echo, FATE has the same contrast properties as FLASH with a slight decrease in signal intensity. The advantage is that the intensity of the signal does not suffer from T2* signal decay, hence improved contrast and disease detection via T2 weighted FATE images is possible. Contrast-to-noise in lesion detection is also considered for CE FAST (Contrast Enhanced Fast), a T2-weighted version of FISP, and HYBRID.

Brain↗

High resolution, magnetization transfer saturation, variable flip angle, time-of-flight MRA in the detection of intracranial vascular stenoses.

OBJECTIVE: Factors that restrict 3D TOF MRA are limited resolution, saturation of flow, and degree of background suppression. We evaluated MRA for intracranial stenoses by using a 3D TOF technique that minimizes these factors. MATERIALS AND METHODS: Twenty-nine patients underwent MRA and intraarterial digital subtraction angiography (DSA). The MRA studies were performed on a 1.5 T Siemens SP 4000 system. Integrated techniques applied to the conventional 3D TOF acquisition included the following: (a) 256 x 256 matrix with a 140 mm FOV and 0.9 mm slice thickness, yielding a 0.54 x 0.54 x 0.9 mm3 voxel; (b) tilted optimized nonsaturating excitation (TONE); and (c) magnetization transfer saturation (MTS). The intraarterial DSA was performed on a Siemens Angiostar system with a 1,024 x 1,024 noninterpolated matrix. The MRAs were reviewed by two neuroradiologists. Two hundred seventy-seven vessels were evaluated for a total of 806 segments. Vessel segments were evaluated with a 5 point scale. RESULTS: The estimated accuracy of MRA for detecting stenosis over all intracranial vessel segments was 0.88 +/- 0.03 and 0.89 +/- 0.02 for the two readers, respectively. The estimated accuracy ranged from 0.94 +/- 0.02 and 0.93 +/- 0.02 for detecting internal carotid artery stenosis by the two readers, respectively, to 0.65 +/- 0.17 and 0.71 +/- 0.15 for detecting distal vertebral artery stenosis. In vessels determined by catheter angiography to be stenosis-free, reader confidence at the proximal versus distal segments was similar for the internal carotid, basilar, and posterior cerebral arteries. However, for the anterior and middle cerebral arteries, one or both readers were more confident in diagnosing the proximal segment. CONCLUSION: High resolution MTS TONE 3D TOF MRA is an accurate technique for the screening of medium and large vessel intracranial stenoses.

Adolescent↗

Hemorrhage detected using MR imaging in the setting of acute stroke: an in vivo model.

BACKGROUND AND PURPOSE: The treatment algorithm for acute cerebrovascular accidents has traditionally sorted these accidents as either hemorrhagic or nonhemorrhagic, and MR imaging, with its ability to allow expeditious assessment of vascular substrates and regional blood volume, is well suited for this purpose. Our purpose was to delineate the accuracy of MR imaging in acute, hemorrhagic forms of stroke during the time frame considered beneficial for intervention in an animal model. METHODS: Eighteen dogs with small, iatrogenic parenchymal, subarachnoid hemorrhage (SAH), or both were serially scanned over the initial 6-hour postictal period. Confirmatory pathologic specimens and 3-hour postictal CT scans were obtained in all animals. The MR and CT studies were then interpreted in a blinded fashion by two neuroradiologists for the presence of hemorrhage. The results were subjected to receiver operating characteristic analysis. RESULTS: MR imaging depicted acute parenchymal hemorrhage and SAH with a high degree of accuracy at 1.5 T. This finding was independent of each of the time points studied during the 6-hour window. For SAH, the MR accuracy for reader 1 was 0.86 (95% CI, 0.76-0.97); for reader 2, accuracy was 0.85 (95% CI, 0.71-0.99). The CT accuracy for the two readers was 0.42 (95% CI, 0.26-0.58) and 0.66 95% CI, 0.43-0.89), respectively. Fluid-attenuated inversion-recovery images improved the conspicuity of SAH on MR images and, along with spin-density-weighted spin-echo sequences, helped to establish the hemorrhagic nature. For parenchymal hemorrhage, the MR accuracy for reader 1 was 0.90 (95% CI, 0.81-0.99); for reader 2, accuracy was 0.93 (95% CI, 0.84-1.00). With CT, the accuracy of reader 1 was 0.91 (95% CI, 0.85-0.97) whereas for reader 2 accuracy was 0.76 (95% CI, 0.69-.83). Parenchymal hemorrhage detection and diagnosis was best with T2*-weighted gradient-echo images. CONCLUSION: MR imaging with appropriately selected sequences appears able to provide information regarding the presence (or absence) of hemorrhage in an acute stroke model requisite to the initiation of treatment.

Acute Disease↗

Gd-DTPA-enhanced 3D MR imaging of cervical degenerative disk disease: initial experience.

PURPOSE: To assess whether a single enhanced T1-weighted gradient echo volume sequence, with the appropriate reformatted images, could be equivalent to a more conventional 2D set of MR sequences for the evaluation of cervical extradural degenerative disk disease (bony canal and foraminal stenosis; disk herniation). MATERIALS AND METHODS: Sixty-one patients evaluated for extradural degenerative disease by MR were imaged with a "standard" MR examination (Sagittal T1-weighted spin echo, axial low flip angle gradient echo), were then given 0.1 mmol/kg Gd-DTPA intravenously, and reimaged with either a 3D FLASH (fast low angle shot), TR 40/TE 7/1 excitation), 40 degree flip angle, acquired as 64, 2-mm sagittal partitions, or a 3D turbo FLASH (MP RAGE-magnetization prepared rapid acquisition gradient echo) (10/4/1), 10 degree flip angle acquired as 128, 2-mm coronal partitions. The volume sequences were reconstructed in the axial plane, and right and left 45 degree oblique coronal planes. The two sets of examinations (standard vs volume) were prospectively interpreted by two neuroradiologists for quality of examination, and location, type, and severity of extradural degenerative disease in a random, blinded, independent fashion. RESULTS: There was no significant difference between the standard examination and the 3D MP RAGE for central extradural disease. The 3D FLASH examination was significantly worse than the standard examination in identification of central extradural disease, with an average of 21 herniations not identified, or underestimated in size. Neither the 3D FLASH, nor the 3D MP RAGE examinations showed any significant improvement compared to the routine 2D examination for the location and severity of foraminal disease. CONCLUSION: If extradural degenerative disk disease is being evaluated, then a single enhanced 3D T1-weighted imaging sequence taking 6 minutes can be equivalent to a routine set of mixed 2D spin echo and low flip angle gradient echo sequences.

Cervical Vertebrae↗

Thoracic aortic disease: evaluation using a single MRA volume series.

OBJECTIVE: Use of MRA for thoracic aortic disease (TAD) evaluation has been limited. This report describes an initial experience with TAD evaluation using a single MRA volume series. MATERIALS AND METHODS: A single volume series, based on sequential 2D TOF MRA, was acquired in 30 cases (28 with suspected TAD and 2 normals). Each series was processed using multiplanar reconstruction (MPR) and maximum intensity projection (MIP); resulting tomographic (one base and two MPR) and MIP sets were blindly interpreted by four reviewers to detect TAD and, if present, to diagnose its specific form. For cases incorrectly interpreted, the standard MR images were subsequently interpreted. RESULTS: The TAD categories included aneurysm (n = 13), dissection (n = 9), and arch anomalies (n = 5). Sensitivities were high for TAD overall (89-100%) and TAD in ascending and descending portions; sensitivities were lower for TAD of the arch (two of four reviewers > or = 90% for TAD overall and descending TAD). Specificities for TAD overall had a wider range (67-100%), but were high for ascending, arch, and descending portions (three to four of four reviewers > or = 90% for each). Sensitivities for aneurysms (69-92%) and dissections overall (67-100%) were comparable, as they were in ascending and arch portions; descending dissection was better detected than descending aneurysm (two of four reviewers > or = 90% for ascending or arch aneurysm and for descending dissection); overall specificities (88-100 vs. 81-95%) and specificities in ascending, arch, and descending portions were also comparable (three to four of four reviewers > or = 90% for both in each portion; two of four reviewers > or = 90% for dissection overall). Each reviewer achieved > or = 70% diagnostic accuracy for TAD (one of four reviewers = 85%); accuracies for each category were comparable. Interpretation of standard MR images corrected all detection and most diagnostic (> or = 63%) errors. CONCLUSION: This initial experience with conventional TOF MRA for TAD evaluation is encouraging, but it indicates the potential for advancements in data acquisition and/or postprocessing.

Adolescent↗