PubMed Health⌕ Search

Biomedical subjects

J A Viator

Publications and source records attributed to J A Viator.

3 recordsLinked to original sources

Iterative reconstruction algorithm for optoacoustic imaging.

Optoacoustic imaging is based on the generation of thermoelastic stress waves by heating an object in an optically heterogeneous medium with a short laser pulse. The stress waves contain information about the distribution of structures with preferential optical absorption. Detection of the waves with an array of broadband ultrasound detectors at the surface of the medium and applying a backprojection algorithm is used to create a map of absorbed energy inside the medium. With conventional reconstruction methods a large number of detector elements and filtering of the signals are necessary to reduce backprojection artifacts. As an alternative this study proposes an iterative procedure. The algorithm is designed to minimize the error between measured signals and signals calculated from the reconstructed image. In experiments using broadband optical ultrasound detectors and in simulations the algorithm was used to obtain three-dimensional images of multiple optoacoustic sources. With signals from a planar array of 3x3 detector elements a significant improvement was observed after about 10 iterations compared to the simple radial backprojection. Compared to conventional methods using filtered backprojection, the iterative method is computationally more intensive but requires less time and instrumentation for signal acquisition.

Journal Article↗

Investigating trends in acoustics research from 1970-1999.

Text data mining is a burgeoning field in which new information is extracted from existing text databases. Computational methods are used to compare relationships between database elements to yield new information about the existing data. Text data mining software was used to determine research trends in acoustics for the years 1970, 1980, 1990, and 1999. Trends were indicated by the number of published articles in the categories of acoustics using the Journal of the Acoustical Society of America (JASA) as the article source. Research was classified using a method based on the Physics and Astronomy Classification Scheme (PACS). Research was further subdivided into world regions, including North and South America, Eastern and Western Europe, Asia, Africa, Middle East, and Australia/New Zealand. In order to gauge the use of JASA as an indicator of international acoustics research, three subjects, underwater sound, nonlinear acoustics, and bioacoustics, were further tracked in 1999, using all journals in the INSPEC database. Research trends indicated a shift in emphasis of certain areas, notably underwater sound, audition, and speech. JASA also showed steady growth, with increasing participation by non-US authors, from about 20% in 1970 to nearly 50% in 1999.

Journal Article↗

Laser thrombolysis using long pulse frequency-doubled Nd:YAG lasers.

BACKGROUND AND OBJECTIVE: Laser thrombolysis is a means for clearing blood clots in occluded arteries. Many researchers have studied the mechanisms of clot ablation, and research clinicians have used the technique to treat myocardial infarction with a number of different laser systems. Specifically, a 1-microsec pulsed dye laser has been used clinically to remove blood clots in coronary arteries. As a comparative study, the ablation characteristics of lasers with pulse durations in the ranges of 50-150 microsec and 2-10 msec were investigated. Two frequency-doubled Nd:YAG lasers at 532 nm were used in this study. Ablation threshold and ablation efficiency of gel phantoms and thrombus using these two lasers were measured and compared with the results of the pulsed dye laser. The pulsed dye laser in this study operated at 522 nm. STUDY DESIGN/MATERIALS AND METHODS: Gelatin samples with 150 cm(-1) absorption coefficient at 532 nm and animal clot were confined to 3-mm silicone tubes to measure ablation parameters. Additional samples with 150 cm(-1) absorption coefficient at 522 nm were prepared for use with the pulsed dye laser. A fluorescence technique and photographic bubble detection were used to determine ablation threshold. A spectrophotometric technique was used to determine ablation efficiency. RESULTS: The ablation threshold of the gel phantoms for all three lasers was determined to be 17 +/- 2 mJ/mm(2). Ablation efficiency for the gel phantoms was 1.7 +/- 0.1 microg/mJ. Clot had an ablation efficiency of 2.9 +/- 1.0 microg/mJ. CONCLUSIONS: Ablation threshold and efficiency are independent of laser pulse duration for 1-microsec, 50-150-microsec, and 2-10-msec pulses (P < 0.05).

Animals↗