PubMed Health⌕ Search

Biomedical subjects

J A Westgate

Publications and source records attributed to J A Westgate.

11 recordsLinked to original sources

Fetal heart rate overshoot during repeated umbilical cord occlusion in sheep.

OBJECTIVE: To assess the clinical utility of overshoot fetal heart rate (FHR) decelerations by examining their occurrence after umbilical cord occlusions of varying frequency and length in near-term fetal sheep. METHODS: Fetuses were allocated to the following three groups: 1-minute umbilical cord occlusion repeated every 5 minutes (1:5 group, n = 8) or every 2.5 minutes (1:2.5 group, n = 8) or 2-minute occlusions repeated every 5 minutes (2:5 group, n = 4). Occlusions were continued for 4 hours or until fetal mean arterial pressure decreased below 20 mmHg during two successive occlusions. RESULTS: In the 1:5 group, fetuses tolerated 4 hours of occlusion without hypotension or clinically significant acidosis and overshoot never occurred. In the 2:5 group, fetuses rapidly became hypotensive and acidotic, and occlusions were terminated at 116.3 +/- 22.9 min (mean +/- standard deviation). Overshoot was seen after every occlusion, starting with the first occlusion. In the 1:2.5 group, fetuses became progressively acidotic and hypotensive and occlusions were stopped at 183.1 +/- 42.8 min. Overshoot occurred after 91.6 +/- 42.5 minutes, at a pH of 7.17 +/- 0.06, base deficit 9.3 +/- 4.5 mmol/L. After the appearance of overshoot there was a more rapid decrease in fetal mean arterial pressure (0.25 [0.21, 0.35, 25-75th percentile] mmHg/minute versus 0.11 [0.03, 0.15] mmHg/minute before overshoot appeared, P <.01). CONCLUSION: These data suggest that overshoot is related to longer (2-minute) occlusions or to developing fetal acidosis and hypotension during 1-minute occlusions. This pattern could have clinical utility, as 1-minute contractions are typical of active labor.

Acidosis↗

ST waveform changes during repeated umbilical cord occlusions in near-term fetal sheep.

OBJECTIVE: This study was undertaken to determine whether changes in the fetal ST waveform during repeated umbilical occlusion reflect the development of hypotension and acidosis. STUDY DESIGN: Chronically instrumented, near-term fetal sheep received 1-minute total umbilical cord occlusion either every 5 minutes for 4 hours (1:5 group, n = 8), or every 2.5 minutes until blood pressure fell <20 mm Hg on 2 successive occlusions (1:2.5 group, n = 8). RESULTS: Umbilical cord occlusion caused variable decelerations, with sustained hypertension in the 1:5 group and little change in acid-base status (pH = 7.34 +/- 0.07 after 4 hours). In contrast, the 1:2.5 group showed progressive hypotension and metabolic acidemia (pH 6.92 +/- 0.1 after the final occlusion). There was a marked increase in ST waveform height during occlusions; this increase was greater in the 1:2.5 group (P <.001), but there was overlap between the groups. ST waveform height between occlusions was significantly higher in the 1:2.5 group (P <.001) until negative and biphasic ST waveforms developed in these fetuses between occlusions in the final 30 minutes. CONCLUSION: ST waveform elevation occurs during umbilical cord occlusions but only crudely reflects the severity of hypoxia. Interocclusion waveform height may be a better reflection of the severity of hypoxia. The appearance of biphasic and negative waveforms between occlusions may be a useful marker for severe decompensation.

Acidosis↗

Fetal seizures causing increased heart rate variability during terminal fetal hypoxia.

Fetal seizures together with both abnormal breathing movements and fluctuations in fetal blood pressure and heart rate resulting in increased fetal heart rate variability have been observed in brain-damaged fetal sheep shortly after an asphyxial insult. We report a clinical example of convulsions and increased heart rate variability during terminal fetal hypoxia.

Adult↗

The evaluation of an expert system for the analysis of umbilical cord blood.

An assessment of neonatal outcome may be obtained from analysis of blood in the umbilical cord of an infant immediately after delivery. This can provide information on the health of the new-born infant, guide requirements for neonatal care, but there are problems with the technique. Samples frequently contain errors in one or more of the important parameters, preventing accurate interpretation and many clinical staff lack the expert knowledge required to interpret error-free results. The development and implementation of an expert system to overcome these difficulties has previously been described. This expert system validates the raw data, provides an interpretation of the results for clinicians and archives all the results, including the quality control and calibration data, for permanent storage. Issues regarding the clinical evaluation of this system are now detailed further, along with some clinical results illustrating the potential of such a system.

Acid-Base Equilibrium↗

Fetal heart rate variability changes during brief repeated umbilical cord occlusion in near term fetal sheep.

OBJECTIVE: To determine whether changes in fetal heart rate variation during repeated umbilical cord occlusions reflect evolving cardiovascular compromise in near term fetal sheep. DESIGN: Fetal heart rate variation, fetal mean arterial pressure, electroencephalogram (EEG) and acid-base status were measured during one minute umbilical cord occlusions, repeated either every five minutes (1:5 group) or every 2.5 minutes (1:2.5 group) for four hours or until mean arterial pressure fell below 20 mmHg for two successive occlusions. SAMPLE: Fourteen chronically instrumented fetal sheep, mean gestation 126.3 (2.6) days. RESULTS: Cord occlusion caused variable decelerations with initial sustained hypertension. In the 1:5 occlusion group mean arterial pressure remained elevated throughout, with little change in acid-base status (pH = 7.34 (0.07), base deficit = 1.3 (3.9) after 4 hours) and no significant change in fetal heart rate variation. In contrast, in the 1:2.5 group from the third occlusion there was progressive hypotension during occlusions, severe progressive metabolic acidaemia (pH 6.92 (0.1), base deficit 17.0 mmol/L (4.7) after the last occlusion) and marked EEG suppression (P < 0.01). Fetal heart rate variation increased with the onset of occlusions (P < 0.05) and then progressively fell with continued occlusions. During the last 30 minutes of occlusions, fetal heart rate variation was severely suppressed in four, but increased in two fetuses, while all six fetuses developed overshoot-instability of fetal heart rate and mean arterial pressure following each occlusion. CONCLUSIONS: Acute progressive asphyxia was typically associated with an immediate, transient increase in fetal heart rate variation. Subsequently variation became suppressed in only two-thirds of fetuses during terminal acidaemia and hypotension. Fetal heart rate overshoot-instability may be a useful marker of fetal decompensation following variable decelerations.

Acidosis↗

Antecedents of neonatal encephalopathy with fetal acidaemia at term.

OBJECTIVE: To identify the relative contribution of antenatal hypoxia, obstetric catastrophe during labour and fetal monitoring practice to the occurrence of neonatal encephalopathy associated with acidaemia at term. DESIGN: Prospective study. SETTING: Tertiary referral hospital in Auckland, New Zealand. SAMPLE: Twenty-two term babies born between January 1996 and October 1997 with umbilical artery pH < or = 7.09 (median 6.88) or 5 minute Apgar score < 7 (median 5.0), and moderate to severe encephalopathy within five hours of birth. METHODS: Antenatal and intrapartum events and fetal heart rate monitoring practice were reviewed by an experienced obstetrician. RESULTS: More than half the cases were associated with events beyond the control of the clinician: 5 of 22 (23%) had evidence of antenatal hypoxia and 5 of 22 (23%) experienced an obstetric catastrophe during labour. Use of continuous fetal monitoring techniques or the interpretation of fetal heart rate changes was suboptimal in 8 of 12 cases. Continuous monitoring was not performed at all in three cases. All pregnancies were of either low or medium risk; none had proteinuric hypertension and no case was breech, small for gestational age or had a gestational age > or = 42 weeks. CONCLUSIONS: A significant proportion of babies with encephalopathy associated with acidaemia at term experienced either antenatal hypoxia or catastrophic events beyond the control of the clinician. Further improvements in obstetric care will require greater vigilance in low to medium risk pregnancies and improved fetal monitoring practice during both induction and labour.

Acidosis↗

Do fetal electrocardiogram PR-RR changes reflect progressive asphyxia after repeated umbilical cord occlusion in fetal sheep?

The aim of this study was to determine whether there is a relationship between changes in PR-RR correlation of the fetal ECG and progressive changes in fetal acid-base status and blood pressure (BP) during repeated umbilical occlusion. Chronically instrumented fetal sheep at 126.8+/-0.6 d (mean+/-SEM) were randomized to receive 1 min of total umbilical cord occlusion either every 5 min for 4 h (1:5 group; n=8), or every 2.5 min until BP fell <2.7 kPa (20 mm Hg) on two successive occlusions (1:2.5 group; n=8). The PR-RR correlation was determined in 5- or 2.5-min intervals. Umbilical cord occlusion caused variable decelerations with initial sustained hypertension. In the 1:5 group BP remained elevated throughout, and there was little change in acid-base status (pH=7.34+/-0.07, base deficit=1.3+/-3.9 after 4 h). In contrast, after the third occlusion the 1:2.5 group showed progressive hypotension during occlusions, and severe progressive metabolic acidemia (pH 6.92+/-0.1, base deficit 17.0+/-4.7 mmol/L after the last occlusion). In both groups, the PR-RR relationship switched from positive to negative with the onset of occlusions, then reverted to positive after a variable interval. In the 1:2.5 group later reversion of the PR-RR to positive was associated with earlier and more prolonged hypotension during the middle and end of the occlusion series (p < 0.001). We conclude that the initial switch to a negative PR-RR relationship during repetitive umbilical occlusion was due to a reflex-mediated response unrelated to fetal acidosis or hypotension. Both stable well compensated fetuses and severely hypoxic, hypotensive fetuses subsequently showed a positive PR-RR correlation.

Animals↗

The development and implementation of an expert system for the analysis of umbilical cord blood.

An assessment of neonatal outcome may be obtained from analysis of blood in the umbilical cord of the infant immediately after delivery. This can provide information on the health of the newborn infant, guide requirements for neonatal care, and is recommended practice of the Royal College of Obstetricians and Gynaecologists. However, there are problems with the technique. Samples frequently contain errors in one or more of the important parameters, preventing accurate interpretation and many clinical staff lack the expert knowledge required to interpret error-free results. In this paper the development and implementation of an expert system to overcome these difficulties is described. The expert system validates results, provides a textual interpretation and archives all results to database for audit, research and medico-legal purposes. The system has now been in routine clinical use for over 3 years in Plymouth, and has also been installed in several other hospitals in the UK. Results are presented in which the types and frequency of errors are established and the user acceptance of the system is determined.

Expert Systems↗

A multicentre comparative study of 17 experts and an intelligent computer system for managing labour using the cardiotocogram.

OBJECTIVES: To investigate 1. whether an intelligent computer system could obtain a performance in labour management comparable with experts when using cardiotocograms (CTGs), patient information, and fetal blood sampling and 2. whether experts could be consistent and agree in their management of labour. SUBJECTS: An intelligent computer system and 17 clinicians experienced in fetal monitoring from 16 centres in the UK. DESIGN: Fifty cases with complete intrapartum CTGs and clinical data were reviewed by each expert and the system independently on two occasions, at least one month apart. Each CTG was scored in 15 min segments according to a protocol and estimates of the cervical dilatation and fetal scalp blood pH were given when requested. MAIN OUTCOME MEASURES: Consistency and agreement in the recorded scores, agreement and timing of cases recommended for caesarean sections, fetal blood sampling rates, intervention in cases with poor outcome and intervention in cases with good clinical outcome. RESULTS: The system: 1. Agreed with experts well and significantly better than chance (67.33%, kappa = 0.31, P << 0.001). 2. Was highly consistent (99.16%, kappa = 0.98, P << 0.001) when used by two operators independently. 3. Recommended no unnecessary intervention in cases with normal delivery and good condition (cord artery pH > 7.15, vein pH > 7.20, 5 min Apgar > or = 9 and no resuscitation). This was better than all but two of the experts. 4. Recommended delivery by caesarean section in 11 cases; at least 15 of the 17 experts in each review also recommended caesarean section delivery in these cases. The majority did so within 15 min of the system and two-thirds did so within 30 min. 5. Identified as many of the birth asphyxiated cases (cord arterial pH < 7.05 and BDecf > or = 12, and Apgar score at 5 min < or = 7 with neonatal morbidity) as the majority of experts and one more than was acted upon clinically. The experts were found to be consistent and to agree. There was good agreement in the cases and the timing of caesarean section recommendations. The majority of experts did not recommend operative intervention in cases which had a normal delivery and good outcome, but did recommend operative interventions in 10 of 12 cases delivered with cord arterial pH < 7.05. However, in one of the cases delivered with birth asphyxia, 14 of the 17 experts and the system failed to recommend intervention. CONCLUSIONS: The system's performance was found to be indistinguishable from the experts' in the 50 cases examined, but it was more consistent. This demonstrates the potential for an intelligent computer system to improve the interpretation of the CTG and decrease intervention. Furthermore, the good performance of most experts in this study demonstrates the potential effectiveness of the CTG and raises important questions regarding why the CTG has fallen short of expectations in current practice.

Cardiotocography↗

Geochronology, stratigraphy and geochemistry of Cindery Tuff in Pliocene hominid-bearing sediments of the Middle Awash, Ethiopia.

Cindery Tuff is a subalkaline, rhyolitic air-fall deposit that was probably produced by a mixed-magma eruption. It is a distinctive, datable, regional isochronous marker bed within the Pliocene sediments of the Middle Awash district, and is stratigraphically situated between two new fossil hominid discoveries. Based on 40Ar/39Ar analyses of plagioclase, rhyolitic glass and basaltic glass, as well as fission-track analyses of zircons, we estimate its age to be 3.8-4.0 Myr. This implies that associated hominid skull fragments are at least 3.9 Myr old.

Animals↗