PubMed Health⌕ Search

Biomedical subjects

J Alison Noble

Publications and source records attributed to J Alison Noble.

At least 19 recordsLinked to original sources

Ultrasound image segmentation: a survey.

This paper reviews ultrasound segmentation paper methods, in a broad sense, focusing on techniques developed for medical B-mode ultrasound images. First, we present a review of articles by clinical application to highlight the approaches that have been investigated and degree of validation that has been done in different clinical domains. Then, we present a classification of methodology in terms of use of prior information. We conclude by selecting ten papers which have presented original ideas that have demonstrated particular clinical usefulness or potential specific to the ultrasound segmentation problem.

Algorithms↗

Adaptive multiscale ultrasound compounding using phase information.

The recent availability of real-time three-dimensional echocardiography offers a convenient, low-cost alternative for detection and diagnosis of heart pathologies. However, a complete description of the heart can be obtained only by combining the information provided by different acoustic windows. We present a new method for compounding 3D ultrasound scans acquired from different views. The method uses multiscale information about ocal structure definition and orientation to weight the contributions of the images. We propose to use image phase to obtain these image characteristics while keeping invariance to image contrast. The monogenic signal provides a convenient, integrated approach for this purpose. We have evaluated our algorithm on synthetic images and heart scans from volunteers, showing it provides a significant improvement in image quality when compared to traditional compounding methods.

Algorithms↗

Pressure-dependent attenuation with microbubbles at low mechanical index.

It has previously been shown that the attenuation of ultrasound (US) by microbubble contrast agents is dependent on acoustic pressure (Chen et al. 2002). Although previous studies have modelled the pressure-dependence of attenuation in single bubbles, this paper investigates this subject by considering a bulk volume of bubbles together with other linear attenuators. Specifically, a new pressure-dependent attenuation model for an inhomogeneous volume of attenuators is proposed. In this model, the effect of the attenuation on US propagation is considered. The model was validated using experimental measurements on the US contrast agent Sonovue. The results indicate, at low acoustic pressures, a linear relationship between the attenuation of Sonovue, measured in dB, and the insonating acoustic pressure.

Humans↗

Temporal calibration of freehand three-dimensional ultrasound using image alignment.

All freehand 3-D ultrasound systems have some latency between the acquisition of an image and its associated position. Previously, estimation of latency has been made by tracking a phantom in a sequence of images and correlating its motion to that recorded by the position sensor. However, tracking-based temporal calibration uses the assumption that latency is constant between scans. This paper presents a new method for temporal calibration that avoids this assumption. Temporal calibration is performed on the scan data by finding the latency at which the best alignment of the 2-D images within the reconstructed volume occurs. The mean voxel intensity variance is used as a global measure of the quality of alignment within the volume and is minimized with respect to latency for each scan. The new method is compared with previous methods using an ultrasound phantom. Finally, integration of temporal calibration with existing spatial calibration methods is discussed.

Calibration↗

A comparison of a similarity-based and a feature-based 2-D-3-D registration method for neurointerventional use.

Two-dimensional (2-D)-to-three-dimensional (3-D) registration can improve visualization which may aid minimally invasive neurointerventions. Using clinical and phantom studies, two state-of-the-art approaches to rigid registration are compared quantitatively: an intensity-based algorithm using the gradient difference similarity measure; and an iterative closest point (ICP)-based algorithm. The gradient difference approach was found to be more accurate, with an average registration accuracy of 1.7 mm for clinical data, compared to the ICP-based algorithm with an average accuracy of 2.8 mm. In phantom studies, the ICP-based algorithm proved more reliable, but with more complicated clinical data, the gradient difference algorithm was more robust. Average computation time for the ICP-based algorithm was 20 s per registration, compared with 14 min and 50 s for the gradient difference algorithm.

Algorithms↗

A system for simultaneously measuring contact force, ultrasound, and position information for use in force-based correction of freehand scanning.

During freehand ultrasound imaging, the sonographer places the ultrasound probe on the patient's skin. This paper describes a system that simultaneously records the position of the probe, the contact force between the probe and skin, and the ultrasound image. The system consists of an ultrasound machine, a probe, a force sensor, an optical localizer, and a host computer. Two new calibration methods are demonstrated: a temporal calibration to determine the time delay between force and position measurements, and a gravitational calibration to remove the effect of gravity on the recorded force. Measurements made with the system showed good agreement with those obtained from a standard materials testing machine. The system's uses include three-dimensional (3-D) ultrasound imaging, force-based deformation correction of ultrasound images, and indentation testing.

Algorithms↗

Quantitative 3-dimensional echocardiography for accurate and rapid cardiac phenotype characterization in mice.

BACKGROUND: Insufficient techniques exist for rapid and reliable phenotype characterization of genetically manipulated mouse models of cardiac dysfunction. We developed a new, robust, 3-dimensional echocardiography (3D-echo) technique and hypothesized that this 3D-echo technique is as accurate as magnetic resonance imaging (MRI) and histology for assessment of left ventricular (LV) volume, ejection fraction, mass, and infarct size in normal and chronically infarcted mice. METHODS AND RESULTS: Using a high-frequency, 7/15-MHz, linear-array ultrasound transducer, we acquired ECG and respiratory-gated, 500-microm consecutive short-axis slices of the murine heart within 4 minutes. The short-axis movies were reassembled off-line in a 3D matrix by using the measured platform locations to position each slice in 3D. Epicardial and endocardial heart contours were manually traced, and a B-spline surface was fitted to the delineated image curves to reconstruct the heart volumes. Excellent correlations were obtained between 3D-echo and MRI for LV end-systolic volumes (r=0.99, P<0.0001), LV end-diastolic volumes (r=0.99, P<0.0001), ejection fraction (r=0.99, P<0.0001), LV mass (r=0.94, P<0.0019), and infarct size (r=0.98, P<0.0001). Also, excellent correlations were found between the 3D-echo-derived LV mass and necropsy LV mass in normal mice (r=0.99, P<0.0001), as well as for 3D-echo-derived infarct size and histologically determined infarct size (r=0.99, P<0.0001) in mice with chronic heart failure. Bland-Altman analysis showed excellent limits of agreement between techniques for all measured parameters. CONCLUSIONS: This new, fast, and highly reproducible 3D-echo technique should be of widespread applicability for high-throughput murine cardiac phenotyping studies.

Animals↗

Computerised planning of the acquisition of cardiac MR images.

A method to automatically plan acquisition of magnetic resonance images aligned with the cardiac axes is presented. Localiser images are acquired with a mean short axis orientation calculated from a group of (n=50) adult patients. These images are segmented using the expectation maximization algorithm. The borders of the ventricular blood pools are found and used to provide an estimate of the orientation of the cardiac axes. These estimated orientations are compared with corresponding manually aligned orientations. The method has been tested on n=12 volunteers showing an error of within 12 degrees which is sufficiently accurate for clinical use.

Adult↗

Vascular segmentation of phase contrast magnetic resonance angiograms based on statistical mixture modeling and local phase coherence.

In this paper, we present an approach to segmenting the brain vasculature in phase contrast magnetic resonance angiography (PC-MRA). According to our prior work, we can describe the overall probability density function of a PC-MRA speed image as either a Maxwell-uniform (MU) or Maxwell-Gaussian-uniform (MGU) mixture model. An automatic mechanism based on Kullback-Leibler divergence is proposed for selecting between the MGU and MU models given a speed image volume. A coherence measure, namely local phase coherence (LPC), which incorporates information about the spatial relationships between neighboring flow vectors, is defined and shown to be more robust to noise than previously described coherence measures. A statistical measure from the speed images and the LPC measure from the phase images are combined in a probabilistic framework, based on the maximum a posteriori method and Markov random fields, to estimate the posterior probabilities of vessel and background for classification. It is shown that segmentation based on both measures gives a more accurate segmentation than using either speed or flow coherence information alone. The proposed method is tested on synthetic, flow phantom and clinical datasets. The results show that the method can segment normal vessels and vascular regions with relatively low flow rate and low signal-to-noise ratio, e.g., aneurysms and veins.

Algorithms↗

Velocity estimation in ultrasound images: a block matching approach.

In this paper, we focus on velocity estimation in ultrasound images sequences. Ultrasound images present many difficulties in image processing because of the typically high level of noise found in them. Recently, Cohen and Dinstein have derived a new similarity measure, according to a simplified image formation model of ultrasound images, optimal in the maximum likelihood sense. This similarity measure is better for ultrasound images than others such as the sum-of-square differences or normalised cross-correlation because it takes into account the fact that the noise in an ultrasound image is multiplicative Rayleigh noise, and that displayed ultrasound images are log-compressed. In this work we investigate the use of this similarity measure in a block matching method. The underlying framework of the method is Singh's algorithm. New improvements are made both on the similarity measure and the Singh algorithm to provide better velocity estimates. A global optimisation scheme for algorithm parameter estimation is also proposed. We show that this optimisation makes an improvement of approximately 35% in comparison to the result obtained with the worst parameter set. Results on clinically acquired cardiac and breast ultrasound sequences, demonstrate the robustness of the method.

Algorithms↗

A novel ultrasound indentation system for measuring biomechanical properties of in vivo soft tissue.

Technologies for soft tissue analysis are advancing at a rapid place. For instance, elastography, which provides soft tissue strain images, is starting to be tried in clinical practice as a tool for diagnosing cancer. Soft tissue deformation modeling and analysis is also an active area of research that has application in surgery planning and treatment. Typically, quantitative soft tissue analysis uses nominal values of soft tissue biomechanical properties. However, in practice, soft tissue properties can vary significantly between individuals. Hence, for soft tissue methodologies to reach their full potential as patient-specific techniques, there is a need to develop ways to efficiently measure soft tissue mechanical properties in vivo. This paper describes a prototype real-time ultrasound (US) indentation test system developed to meet this need. The system is based on the integration of a force sensor and an optical tracking system with a commercial US machine integrated with a suite of analysis methodologies. In a study on a single-layer phantom, we used the system to compare various methods of estimating linear elastic properties (via a theoretical approximation, 2-D finite element analysis, 3-D finite element analysis and a standard material-testing method). In a second study on a three-layer gelatin phantom, we describe a new finite-element-based inverse solution for recovering the Young's moduli of each layer to show how the system can estimate properties of internal components of soft tissue. Finally, we show how the system can be used to derive a modified quasilinear viscoelastic (QVL) model on real breast tissue.

Biomechanical Phenomena↗

MAP MRF joint segmentation and registration of medical images.

The problems of segmentation and registration are traditionally approached individually, yet the accuracy of one is of great importance in influencing the success of the other. In this paper, we aim to show that more accurate and robust results may be obtained through seeking a joint solution to these linked processes. The outlined approach applies Markov random fields in the solution of a maximum a posteriori model of segmentation and registration. The approach is applied to synthetic and real MRI data.

Algorithms↗

Intensity-based 2-D-3-D registration of cerebral angiograms.

We propose a new method for aligning three-dimensional (3-D) magnetic resonance angiography (MRA) with 2-D X-ray digital subtraction angiograms (DSA). Our method is developed from our algorithm to register computed tomography volumes to X-ray images based on intensity matching of digitally reconstructed radiographs (DRRs). To make the DSA and DRR more similar, we transform the MRA images to images of the vasculature and set to zero the contralateral side of the MRA to that imaged with DSA. We initialize the search for a match on a user defined circular region of interest. We have tested six similarity measures using both unsegmented MRA and three segmentation variants of the MRA. Registrations were carried out on images of a physical neuro-vascular phantom and images obtained during four neuro-vascular interventions. The most accurate and robust registrations were obtained using the pattern intensity, gradient difference, and gradient correlation similarity measures, when used in conjunction with the most sophisticated MRA segmentations. Using these measures, 95% of the phantom start positions and 82% of the clinical start positions were successfully registered. The lowest root mean square reprojection errors were 1.3 mm (standard deviation 0.6) for the phantom and 1.5 mm (standard deviation 0.9) for the clinical data sets. Finally, we present a novel method for the comparison of similarity measure performance using a technique borrowed from receiver operator characteristic analysis.

Algorithms↗

Automated, nonrigid alignment of clinical myocardial contrast echocardiography image sequences: comparison with manual alignment.

Analysis of myocardial contrast echocardiography (MCE) images is currently done by manual techniques. The development of computationally efficient methods for aligning images provides an important first step toward the automation of MCE analysis. This is challenging because a nonrigid transformation correction is required. In this paper, we evaluate a state-of-the-art nonrigid alignment method on clinical MCE image sequences (n = 58) acquired on patients during rest and dipyridamole stress, using both B-mode intermittent ultraharmonic (IUH) imaging and real-time myocardial perfusion imaging (RTMPI). Using manual alignment as the reference, we show quantitatively that the automated method aligns images as well as a human observer. However, the new method is faster and more reliable than manual alignment and removes the need for an experienced physician to perform it. The automated technique can be used for quick poststudy off-line analysis and has the potential to be incorporated into an ultrasound machine.

Automation↗

Fusing speed and phase information for vascular segmentation of phase contrast MR angiograms.

This paper presents a statistical approach to aggregating speed and phase (directional) information for vascular segmentation of phase contrast magnetic resonance angiograms (PC-MRA). Rather than relying on speed information alone, as done by others and in our own work, we demonstrate that including phase information as a priori knowledge in a Markov random field (MRF) model can improve the quality of segmentation. This is particularly true in the region within an aneurysm where there is a heterogeneous intensity pattern and significant vascular signal loss. We propose to use a Maxwell-Gaussian mixture density to model the background signal distribution and combine this with a uniform distribution for modelling vascular signal to give a Maxwell-Gaussian-uniform (MGU) mixture model of image intensity. The MGU model parameters are estimated by the modified expectation-maximisation (EM) algorithm. In addition, it is shown that the Maxwell-Gaussian mixture distribution (a) models the background signal more accurately than a Maxwell distribution, (b) exhibits a better fit to clinical data and (c) gives fewer false positive voxels (misclassified vessel voxels) in segmentation. The new segmentation algorithm is tested on an aneurysm phantom data set and two clinical data sets. The experimental results show that the proposed method can provide a better quality of segmentation when both speed and phase information are utilised.

Algorithms↗

Segmentation of ultrasound B-mode images with intensity inhomogeneity correction.

Displayed ultrasound (US) B-mode images often exhibit tissue intensity inhomogeneities dominated by nonuniform beam attenuation within the body. This is a major problem for intensity-based, automatic segmentation of video-intensity images because conventional threshold-based or intensity-statistic-based approaches do not work well in the presence of such image distortions. Time gain compensation (TGC) is typically used in standard US machines in an attempt to overcome this. However this compensation method is position-dependent which means that different tissues in the same TGC time-range (or corresponding depth range) will be, incorrectly, compensated by the same amount. Compensation should really be tissue-type dependent but automating this step is difficult. The main contribution of this paper is to develop a method for simultaneous estimation of video-intensity inhomogeities and segmentation of US image tissue regions. The method uses a combination of the maximum a posteriori (MAP) and Markov random field (MRF) methods to estimate the US image distortion field assuming it follows a multiplicative model while at the same time labeling image regions based on the corrected intensity statistics. The MAP step is used to estimate the intensity model parameters while the MRF step provides a novel way of incorporating the distributions of image tissue classes as a spatial smoothness constraint. We explain how this multiplicative model can be related to the ultrasonic physics of image formation to justify our approach. Experiments are presented on synthetic images and a gelatin phantom to evaluate quantitatively the accuracy of the method. We also discuss qualitatively the application of the method to clinical breast and cardiac US images. Limitations of the method and potential clinical applications are outlined in the conclusion.

Algorithms↗

A shape-space-based approach to tracking myocardial borders and quantifying regional left-ventricular function applied in echocardiography.

This paper presents a new semi-automatic method for quantifying regional heart function from two-dimensional echocardiography. In the approach, we first track the endocardial and epicardial boundaries using a new variant of the dynamic snake approach. The tracked borders are then decomposed into clinically meaningful regional parameters, using a novel interpretational shape-space motivated by the 16-segment model used in clinical practice for qualitative assessment of heart function. We show how a quantitative and automatic scoring scheme for the endocardial excursion and myocardial thickening can be derived from this. Results illustrating our approach on apical long-axis two-chamber-view data from a patient with a myocardial infarct in the apical anterior/inferior region of the heart are presented. In a case study (five patients, nine data sets) the performance of the tracking and interpretation techniques are compared with manual delineations of borders using a number of quantitative measures of regional comparison.

Algorithms↗

Nonrigid registration of 3-D free-hand ultrasound images of the breast.

Three-dimensional (3-D) ultrasound imaging of the breast enables better assessment of diseases than conventional two-dimensional (2-D) imaging. Free-hand techniques are often used for generating 3-D data from a sequence of 2-D slice images. However, the breast deforms substantially during scanning because it is composed primarily of soft tissue. This often causes tissue mis-registration in spatial compounding of multiple scan sweeps. To overcome this problem, in this paper, instead of introducing additional constraints on scanning conditions, we use image processing techniques. We present a fully automatic algorithm for 3-D nonlinear registration of free-hand ultrasound data. It uses a block matching scheme and local statistics to estimate local tissue deformation. A Bayesian regularization method is applied to the sample displacement field. The final deformation field is obtained by fitting a B-spline approximating mesh to the sample displacement field. Registration accuracy is evaluated using phantom data and similar registration errors are achieved with (0.19 mm) and without (0.16 mm) gaps in the data. Experimental results show that registration is crucial in spatial compounding of different sweeps. The execution time of the method on moderate hardware is sufficiently fast for fairly large research studies.

Algorithms↗