PubMed Health⌕ Search

Biomedical subjects

J Anthony Parker

Publications and source records attributed to J Anthony Parker.

At least 19 recordsLinked to original sources

Extravazation of therapeutic yttrium-90-ibritumomab tiuxetan (zevalin): a case report.

The occurrence of radiation necrosis to the extravasation of therapeutic radionuclide-yttrium-90-ibritumomab tiuxetan-is described, as well as the subsequent steps taken to both address the occurrence and to prevent the re-occurrence of such an adverse event. Published reports on the extravasation of diagnostic and therapeutic radionuclides are reviewed, as are prevention and treatment protocols.

Antibodies, Monoclonal↗

False-positive axillary lymph node on FDG-PET/CT scan resulting from immunization.

An initial CT of a 59-year-old man with increasing back pain and weight loss showed lymphadenopathy in multiple nodal beds. A biopsy showed diffuse, large B-cell lymphoma (DLBCL). After initial chemotherapy, residual disease prompted an autologous stem cell transplant. After a follow-up FDG-PET/CT scan showed no FDG-avid disease, a subsequent study showed FDG uptake in a nonenlarged left axillary lymph node. Questioning elicited a recent immunization history. A follow-up PET/CT scan showed no uptake in this lymph node and no disease recurrence. Without this history, an unnecessary biopsy or treatment may have ensued. Methods to avoid such occurrences are discussed.

Axilla↗

Prone SPECT myocardial perfusion imaging is associated with less cardiac drift during the acquisition duration than imaging in the supine position.

BACKGROUND AND AIM: Cardiac cranial drift, a slow vertical upward displacement seen during the acquisition of myocardial single photon emission tomography (SPECT), is a source of image artefacts that may lead to erroneous interpretation. Changes in breathing pattern and depth throughout image acquisition are believed to cause cardiac cranial drift. As the physiology of respiration probably differs with postural changes, we hypothesized that cardiac drift may be different for supine vs. prone acquisitions. Our aim was to assess the magnitude of cardiac displacement for prone and supine SPECT acquisitions in patients undergoing stress myocardial perfusion imaging. METHODS: We enrolled prospectively 15 subjects undergoing exercise myocardial perfusion imaging. Subjects had post-stress images acquired in both the prone and supine positions. Motion was assessed in the horizontal (x) and vertical (y) axes for both camera heads at all 64 projections at which images were obtained. Pixel displacement (number of pixels from the baseline of zero) in either the cranial/caudal or left/right direction was quantified using the automated camera motion correction algorithm. RESULTS: Supine imaging was associated with more cranial drift than prone imaging (1.20+/-0.40 pixels vs. 0.92+/-0.24 pixels, P<0.05). There was no significant difference in cardiac displacement in the horizontal axis (1.03+/-0.5 pixels vs. 1.12+/-0.22 pixels, P=NS). CONCLUSIONS: Prone imaging is associated with less cardiac cranial drift than imaging in the supine position, suggesting that the former is associated with a more constant and reliable diaphragmatic breathing pattern. Acquisitions in the prone position may thus be associated with fewer motion artefacts than supine acquisitions for cardiac SPECT imaging.

Adult↗

Near-infrared fluorescent type II quantum dots for sentinel lymph node mapping.

The use of near-infrared or infrared photons is a promising approach for biomedical imaging in living tissue. This technology often requires exogenous contrast agents with combinations of hydrodynamic diameter, absorption, quantum yield and stability that are not possible with conventional organic fluorophores. Here we show that the fluorescence emission of type II quantum dots can be tuned into the near infrared while preserving absorption cross-section, and that a polydentate phosphine coating renders them soluble, disperse and stable in serum. We then demonstrate that these quantum dots allow a major cancer surgery, sentinel lymph node mapping, to be performed in large animals under complete image guidance. Injection of only 400 pmol of near-infrared quantum dots permits sentinel lymph nodes 1 cm deep to be imaged easily in real time using excitation fluence rates of only 5 mW/cm(2). Taken together, the chemical, optical and in vivo data presented in this study demonstrate the potential of near-infrared quantum dots for biomedical imaging.

Animals↗

Systems for remote interpretation of emergency studies.

Telenuclear medicine facilitates a timely expert interpretation of emergency nuclear medicine studies. Current, high-speed Internet connection allows nuclear medicine physicians to be on-call from their homes. Software to support telenuclear medicine is becoming more widely available, although the design of some departments makes implementation difficult. Quality control of the remote monitor requires special attention to ensure correct interpretation. Fortunately, monitor quality control can be performed quickly using relatively simple procedures. Thus, expert interpretation of emergency nuclear medicine studies is practical.

Acute Disease↗

ECG-gated 99mTc single-photon emission CT for assessment of right ventricular structure and function: is the information provided similar to echocardiography?

STUDY OBJECTIVE: (99m)Tc single-photon emission CT (SPECT) and ECG-gated SPECT can visualize well the right ventricle (RV) in most patients, but their utility for assessment of the RV has not been formally evaluated. We examined whether (99m)Tc SPECT/ECG-gated SPECT provide similar information to transthoracic two-dimensional Doppler echocardiography (2D-ECHO) regarding RV cavity size, wall thickness, and systolic function. DESIGN: Retrospective analysis. SETTING: A major university teaching hospital. PATIENTS: A consecutive series of 194 patients with good quality stress SPECT and 2D-ECHO studies performed within 1 day of each other and no significant interim cardiac events. MEASUREMENTS AND RESULTS: RV size and function were visually assessed by SPECT/ECG-gated SPECT and 2D-ECHO. RV wall thickness was visually assessed by SPECT and measured in mm in end-diastole by 2D-ECHO. Of 142 patients with normal RV cavity size by SPECT, 134 patients (94%) had normal RV cavity size by 2D-ECHO. However, of 52 patients with RV dilation by SPECT, only 9 patients (17%) had RV dilation by 2D-ECHO. A perfusion abnormality in the right coronary artery territory was significantly associated with RV dilation by SPECT (p < 0.005) and 2D-ECHO (p < 0.05). Among 150 patients with ECG-gated SPECT, only 2 patients had abnormal RV systolic function, as compared with 18 patients by 2D-ECHO. RV wall thickness measurements by SPECT and 2D-ECHO did not correlate. CONCLUSIONS: For normal interpretations regarding RV cavity size, wall thickness, and systolic function, there is good agreement between (99m)Tc stress SPECT/ECG-gated SPECT and 2D-ECHO. However, there is poor overall agreement between gated SPECT/ECG-gated SPECT and 2D-ECHO regarding the presence of RV dilation, hypertrophy, and systolic dysfunction.

Echocardiography, Doppler↗

Correlation of cerebral blood flow and treatment effects of repetitive transcranial magnetic stimulation in depressed patients.

The aims of this study were to: (1) assess the effects of repetitive transcranial magnetic stimulation (rTMS) on brain activity in depressed patients as measured by single photon emission tomography (SPECT); (2) evaluate the predictive value of brain SPECT on the antidepressant efficacy of rTMS. Patients (n=17) received 1600 rTMS stimuli at a rate of 10 Hz, 5 days per week for 2 weeks to the left dorsolateral prefrontal cortex. Whole brain SPECT data were acquired using Tc99m-Bicisate. Regional cerebral blood flow (rCBF) was correlated with the % change in the 28-item Hamilton Depression Rating Scale Score (Delta-HDRS) and a semiquantitative region of interest (ROI) analysis was conducted. Prior to rTMS there was a significant left-right asymmetry favoring the right, whereas 2 weeks after the rTMS treatment this asymmetry was reversed. The rCBF in limbic structures was negatively correlated with the outcome and rCBF in several neocortical areas was positively correlated. Brain SPECT can provide information about mechanisms of action of rTMS and may have predictive value for the antidepressant efficacy of rTMS.

Adolescent↗

Sub-millimeter technetium-99m calibration sources.

PURPOSE: Small animal radioscintigraphic imaging systems aim to achieve sub-millimeter resolution. At the present time, sub-millimeter calibration sources that can be placed at will within an imaged volume are not readily available. We have developed a method for producing technetium-99m (Tc-99m) sources in less than 15 minutes with readily available reagents. PROCEDURES: Tc-99m pertechnetate [TcO(4)](-) was incubated with 45 microm to 106 microm diameter spherical anion exchange beads, washed, and mounted as desired for instrument calibration. RESULTS: The procedure yields spherical sources having between 6.8 microCi to 11.1 microCi of Tc-99m per source. This work shows that dual imaging of these sources using white light and radioscintigraphy permits measurement of system performance with high precision. CONCLUSION: Easily prepared, sub-millimeter Tc-99m spherical calibration sources are described, and it is demonstrated that such sources are useful for measuring the resolution and sensitivity of radioscintigraphic systems, such as those designed for small animal imaging.

Journal Article↗

Long-term effects of surgical angiogenic therapy with fibroblast growth factor 2 protein.

OBJECTIVE: The long-term effects of surgical fibroblast growth factor 2 therapy are examined. METHODS: In a randomized, double-blind study, fibroblast growth factor 2 (10 microg or 100 microg) or placebo (n = 8 each) was delivered in the ungraftable myocardial territory of patients concomitantly undergoing coronary artery bypass grafting. Patients were followed up to 32.2 +/- 6.8 months postoperatively with clinical assessment and nuclear perfusion imaging. RESULTS: Baseline patient characteristics were similar between the 3 groups. There were 2 late deaths, one of pancreatic cancer and one of undetermined cause (both in the 100-microg fibroblast growth factor 2 group). Two patients (both in the control group) underwent a total of 6 repeat cardiac catheterizations for recurrent coronary events. Mean Canadian Cardiovascular Society angina class improved at late follow-up from baseline in all groups (P < or = .02); however, patients treated with either dose of fibroblast growth factor 2 had significantly more freedom from angina recurrence than those treated with placebo (P =.03). Late nuclear perfusion scans revealed a persistent reversible or a new, fixed perfusion defect in the ungraftable territory of 4 of 5 patients who received placebo versus only 1 of 9 patients treated with fibroblast growth factor 2 (P =.02). The overall sum of left ventricular stress perfusion defect scores was also lower in fibroblast growth factor 2-treated patients than in control subjects (1.3 +/- 1.4 vs 3.9 +/- 2.1, respectively; P =.04). A trend toward a higher late left ventricular ejection fraction was noted in fibroblast growth factor 2-treated patients (55.1% +/- 14.6% vs 44.3% +/- 6.5%, fibroblast growth factor 2-treated patients versus control subjects; P =.12). CONCLUSIONS: These data suggest that surgical angiogenic therapy with sustained-release fibroblast growth factor 2 may result in a prolonged myocardial revascularization effect that could translate into clinical benefit.

Coronary Artery Bypass↗

Apical hypertrophic cardiomyopathy: clinical, electrocardiographic, scintigraphic, echocardiographic, and magnetic resonance imaging findings of a case.

The apical variant of nonobstructive hypertrophic cardiomyopathy (HCM) constitutes a minority of all cases of HCM and generally carries a favorable clinical outcome. We describe a 68 year-old Caucasian woman who presented with exertional dyspnea. The patient underwent stress testing with electrocardiogram-gated single-photon emission computed tomography imaging and resting transthoracic echocardiography. The patient also underwent cardiac magnetic resonance imaging at rest, including conventional structural and functional imaging and cine complementary spatial modulation of magnetization-tagged imaging (CSPAMM). The noninvasive evaluation of the heart demonstrated apical hypertrophy with regional systolic dysfunction, establishing the diagnosis of apical HCM. This case suggests a potential value of CSPAMM in characterizing apical HCM.

Aged↗

Quantitative relationship of stress Tc-99m sestamibi lung uptake with resting Tl-201 lung uptake and with indices of left ventricular dysfunction and coronary artery disease.

BACKGROUND: We investigated the relationship of stress technetium 99m sestamibi lung uptake with rest thallium 201 lung uptake and with indices of left ventricular (LV) dysfunction and severity of coronary artery disease (CAD) in patients with known or suspected CAD undergoing stress testing and cardiac catheterization. Stress Tc-99m sestamibi lung uptake and both stress and rest Tl-201 lung uptake are associated with LV dysfunction and extent of CAD. Although the mechanism of lung uptake is thought to be similar for the two isotopes, their physiologic characteristics are different. No direct comparison of lung uptake for the two isotopes has been reported. METHODS AND RESULTS: We evaluated 192 consecutive patients who underwent dual-isotope myocardial perfusion imaging and cardiac catheterization within 30 days. We examined the relationship of stress Tc-99m sestamibi lung-to-heart ratio (LHR) with rest Tl-201 LHR, with indices of myocardial perfusion, and with invasive measures of the severity of LV dysfunction and CAD. Stress Tc-99m sestamibi LHR correlated with rest Tl-201 LHR (r = 0.548, P <.001). Stress Tc-99m sestamibi LHR was positively associated with LV filling pressures and extent of CAD and negatively associated with LV ejection fraction and arterial systolic blood pressure. However, after adjustment for multiple comparisons, stress Tc-99m sestamibi LHR was significantly associated only with LV end-diastolic pressure (r = 0.287, P =.002) and pulmonary capillary wedge pressure (r = 0.337, P <.001). CONCLUSIONS: Increased stress Tc-99m sestamibi LHR correlates with rest Tl-201 LHR in patients with known or suspected CAD. Stress Tc-99m sestamibi lung uptake is also associated with invasively measured LV filling pressures.

Coronary Artery Disease↗

Increased resting Tl-201 lung-to-heart ratio is associated with invasively determined measures of left ventricular dysfunction, extent of coronary artery disease, and resting myocardial perfusion abnormalities.

BACKGROUND: Stress lung thallium 201 uptake correlates with left ventricular (LV) dysfunction and extent of coronary artery disease (CAD). Although Tl-201 is used less commonly for stress imaging, dual-isotope stress and viability protocols continue to use Tl-201 for rest imaging. We sought to investigate the association between increased resting Tl-201 lung-to-heart ratio (LHR) and hemodynamic indices of LV dysfunction, indices of myocardial perfusion, and extent of CAD. METHODS AND RESULTS: Over a 1-year period, we identified 192 consecutive patients who underwent dual-isotope stress perfusion imaging and cardiac catheterization within 30 days, without interim events or revascularization. Resting LHR was measured, and its association with invasively measured hemodynamic parameters, extent of CAD, and indices of myocardial perfusion at rest and stress was examined. Increased resting Tl-201 LHR was weakly but significantly associated with lower LV ejection fraction (EF) (r = 0.209, P <.05), higher pulmonary capillary wedge pressure (r = 0.25, P <.005), and LV end-diastolic pressure (r = 0.215, P <.01) but not with pulmonary artery systolic pressure. Increased LHR was also weakly associated with rest perfusion abnormalities including the sum rest score (r = 0.271, P <.001) and number of abnormally perfused segments (r = 0.25, P <.001) bud did not correlate with stress perfusion indices or ischemic burden. The 76 patients (40%) with LHR greater than 0.5 were more likely to have LVEF lower than 40% and 3-vessel/left main CAD. CONCLUSIONS: Increased rest Tl-201 LHR is weakly associated with higher LV end-diastolic pressure and pulmonary capillary wedge pressure and lower LVEF. LHR is also associated with the extent of previously infarcted myocardium and may indicate the presence of 3-vessel/left main CAD.

Age Factors↗