Publications and source records attributed to J Anthony Seibert.

17 recordsLinked to original sources

Flat-panel detectors: how much better are they?

Interventional and fluoroscopic imaging procedures for pediatric patients are becoming more prevalent because of the less-invasive nature of these procedures compared to alternatives such as surgery. Flat-panel X-ray detectors (FPD) for fluoroscopy are a new technology alternative to the image intensifier/TV (II/TV) digital system that has been in use for more than two decades. Two major FPD technologies have been implemented, based on indirect conversion of X-rays to light (using an X-ray scintillator) and then to proportional charge (using a photodiode), or direct conversion of X-rays into charge (using a semiconductor material) for signal acquisition and digitization. These detectors have proved very successful for high-exposure interventional procedures but lack the image quality of the II/TV system at the lowest exposure levels common in fluoroscopy. The benefits for FPD image quality include lack of geometric distortion, little or no veiling glare, a uniform response across the field-of-view, and improved ergonomics with better patient access. Better detective quantum efficiency indicates the possibility of reducing the patient dose in accordance with ALARA principles. However, first-generation FPD devices have been implemented with less than adequate acquisition flexibility (e.g., lack of tableside controls/information, inability to easily change protocols) and the presence of residual signals from previous exposures, and additional cost of equipment and long-term maintenance have been serious impediments to purchase and implementation. Technological advances of second generation and future hybrid FPD systems should solve many current issues. The answer to the question "how much better are they?" is "significantly better", and they are certainly worth consideration for replacement or new implementation of an imaging suite for pediatric fluoroscopy.

Body Burden↗

Description and implementation of a quality control program in an imaging-based clinical trial.

RATIONALE AND OBJECTIVES: The American College of Radiology Imaging Network is participating in the National Lung Screening Trial, a large, multicenter, randomized controlled trial, comparing multidetector helical computed tomography (MDCT) versus chest radiography (CXR) in screening for lung cancer. Because the threshold for detection of disease is an inherent function of image quality, and consistent image quality is necessary to track changes in suspicious findings, our purpose was to develop an image quality control (QC) program across all clinical sites for both modalities. MATERIALS AND METHODS: The primary goals of the QC program include standardization of imaging protocols, certification of imaging equipment, and ongoing, periodic evaluation of the equipment calibration and image quality. Minimum standards for equipment and standardized cross-platform acquisition protocols are achieved via radiologist and physicist attestation forms and web-distributed technique charts, respectively. Imaging equipment performance standards are implemented through an initial machine certification process that includes equipment calibration. Ongoing assessment of equipment performance and calibration, as well as adherence to established imaging protocols. is accomplished via periodic submission of calibration records and phantom images. Participant-specific image acquisition parameters are entered into a web-based centralized database and variations from established protocols are automatically flagged for review. Participant radiation dose can be estimated from the image acquisition parameters applied to the imaging equipment calibration measurements. A radiologist visual review committee also evaluates participant images for diagnostic quality. Data are collected from 23 independent centers, representing 14 models of MDCT scanners from four manufacturers, and CXR systems that include film-screen, computed radiography, and direct digital radiography systems. RESULTS: Widespread imaging protocol variation in extant clinical practice-as well as variability in equipment technology, image acquisition parameters, manufacturer terminology, and user interface-have required careful standardization as a prerequisite to trial participation and ongoing image QC. Acceptable ranges for image acquisition parameters have been refined to accommodate continuously evolving equipment platforms and the scope of participant size and body habitus. CONCLUSION: Standardization of imaging protocols is a critical component of image-based clinical trials, predicated on ongoing dialogue between sites and a centralized review committee.

Artificial Intelligence↗

An improved method for flat-field correction of flat panel x-ray detector.

In this Technical Note, the effects of different flat-field techniques are examined for a cesium iodide flat panel detector, which exhibited a slightly nonlinear exposure response. The results indicate that the variable flat-field correction method with the appropriate polynomial fit provides excellent correction throughout the entire exposure range. The averaged normalized variation factor, used to assess the nonuniformity of the flat-field correction, decreased from 30.76 for the fixed correction method to 4.13 for the variable flat-field correction method with a fourth-order polynomial fit for the 60 kVp spectrum, and from 16.42 to 3.97 for the 95 kVp spectrum.

Cesium↗

Technique factors and their relationship to radiation dose in pendant geometry breast CT.

The use of breast computed tomography (CT) as an alternative to mammography in some patients is being studied at several institutions. However, the radiation dosimetry issues associated with breast CT are markedly different than in the case of mammography. In this study, the spectral properties of an operational breast CT scanner were characterized both by physical measurement and computer modeling of the kVp-dependent spectra, from 40 to 110 kVp (Be window W anode with 0.30 mm added Cu filtration). Previously reported conversion factors, normalized glandular dose for CT-DgN(ct), derived from Monte Carlo methods, were used in concert with the output spectra of the breast scanner to compute the mean glandular dose to the breast based upon different combinations of x-ray technique factors (kVp and mAs). The mean glandular dose (MGD) was measured as a function of the compressed breast thickness (2-8 cm) and three different breast compositions (0%, 50%, and 100% glandular fractions) in four clinical mammography systems in our institution. The average MGD from these four systems was used to compute the technique factors for breast CT systems that would match the two-view mammographic dose levels. For a 14 cm diameter breast (equivalent to a 5 cm thick compressed breast in mammography), air kerma levels at the breast CT scanner's isocenter (468 mm from the source) of 4.4, 6.4, and 9.0 mGy were found to deliver equivalent mammography doses for 0%, 50%, and 100% glandular breasts (respectively) at 80 kVp. At 80 kVp (where air kerma was 11.3 mGy/100 mAs at the isocenter), 57 mAs (integrated over the entire scan) was required to match the mammography dose for a 14 cm 50% glandular breast. At 50 kVp, 360 mAs is required to match mammographic dose levels. Tables are provided for both air kerma at the isocenter and mAs for 0%, 50%, and 100% glandular breasts. Other issues that impact breast CT technique factors are also discussed.

Biophysical Phenomena↗

X-ray imaging physics for nuclear medicine technologists. Part 2: X-ray interactions and image formation.

The purpose is to review in a 4-part series: (i) the basic principles of x-ray production, (ii) x-ray interactions and data capture/conversion, (iii) acquisition/creation of the CT image, and (iv) operational details of a modern multislice CT scanner integrated with a PET scanner. In part 1, the production and characteristics of x-rays were reviewed. In this article, the principles of x-ray interactions and image formation are discussed, in preparation for a general review of CT (part 3) and a more detailed investigation of PET/CT scanners in part 4.

Nuclear Medicine↗

Addressing the coming radiology crisis-the Society for Computer Applications in Radiology transforming the radiological interpretation process (TRIP) initiative.

The Society for Computer Applications in Radiology (SCAR) Transforming the Radiological Interpretation Process (TRIP) Initiative aims to spearhead research, education, and discovery of innovative solutions to address the problem of information and image data overload. The initiative will foster interdisciplinary research on technological, environmental and human factors to better manage and exploit the massive amounts of data. TRIP will focus on the following basic objectives: improving the efficiency of interpretation of large data sets, improving the timeliness and effectiveness of communication, and decreasing medical errors. The ultimate goal of the initiative is to improve the quality and safety of patient care. Interdisciplinary research into several broad areas will be necessary to make progress in managing the ever-increasing volume of data. The six concepts involved are human perception, image processing and computer-aided detection (CAD), visualization, navigation and usability, databases and integration, and evaluation and validation of methods and performance. The result of this transformation will affect several key processes in radiology, including image interpretation; communication of imaging results; workflow and efficiency within the health care enterprise; diagnostic accuracy and a reduction in medical errors; and, ultimately, the overall quality of care.

Humans↗

Automated recognition of lateral from PA chest radiographs: saving seconds in a PACS environment.

Images acquired in a two-view digital chest examination are frequently not electronically distinguishable. As a result the lateral and posterioanterio (PA) images are often improperly positioned on a PACS work station. A series of 1998 chest radiographs (999 lateral, 999 PA or AP) were used to develop a neural network classifier. The images were down-sampled to 16 x 16 matrices, and a feed-forward neural network was trained and tested using the "leave-one-out" method. Using five nodes in the hidden layer, the neural network correctly identified 987 of the 999 test cases (98.8%) (average of six runs). The simple architecture and speed of this technique suggests that it would be a useful addition to PACS work station software. The accumulated time saved by correctly positioning the lateral and PA chest images on the work station monitors in accordance with each radiologist's hanging protocols was estimated to be about 1 week of radiologist time per year.

Electronic Data Processing↗

Tradeoffs between image quality and dose.

Image quality takes on different perspectives and meanings when associated with the concept of as low as reasonably achievable (ALARA), which is chiefly focused on radiation dose delivered as a result of a medical imaging procedure. ALARA is important because of the increased radiosensitivity of children to ionizing radiation and the desire to keep the radiation dose low. By the same token, however, image quality is also important because of the need to provide the necessary information in a radiograph in order to make an accurate diagnosis. Thus, there are tradeoffs to be considered between image quality and radiation dose, which is the main topic of this article. ALARA does not necessarily mean the lowest radiation dose, nor, when implemented, does it result in the least desirable radiographic images. With the recent widespread implementation of digital radiographic detectors and displays, a new level of flexibility and complexity confronts the technologist, physicist, and radiologist in optimizing the pediatric radiography exam. This is due to the separation of the acquisition, display, and archiving events that were previously combined by the screen-film detector, which allows for compensation for under- and overexposures, image processing, and on-line image manipulation. As explained in the article, different concepts must be introduced for a better understanding of the tradeoffs encountered when dealing with digital radiography and ALARA. In addition, there are many instances during the image acquisition/display/interpretation process in which image quality and associated dose can be compromised. This requires continuous diligence to quality control and feedback mechanisms to verify that the goals of image quality, dose and ALARA are achieved.

Child↗

Comparison of dual energy detector system performance.

Dual energy detector systems are combinations of x-ray detectors, x-ray source spectrum switching, and x-ray filter attenuation that provide two measurements of transmitted flux through the object with different effective spectra. We describe technology independent methods to measure and compare the quantum noise and sensitivity to motion artifacts of these systems. The experimental methods use relatively simple phantoms to measure the parameters in the general mathematical expressions for the noise in the subtracted image. The parameters are used to compute an x-ray energy spectrum quality factor and a subtracted image noise per unit patient dose quality factor. Patient motion causes artifacts in switched spectrum systems, particularly with the heart in chest radiography. We describe a method to measure effective interexposure time using subtracted image data of a uniformly moving object. This parameter measures the sensitivity to patient motion artifacts. We use these methods to compare three examples of systems with different dual energy detector technologies: a passive, "sandwich" detector with two computed radiography plates separated by a copper filter, an "active" detector that uses voltage switching with an electro-optical system and computed radiography plates, and a flat-panel, solid state detector with voltage switching.

Artifacts↗

X-ray imaging physics for nuclear medicine technologists. Part 1: Basic principles of x-ray production.

The purpose is to review in a 4-part series: (i) the basic principles of x-ray production, (ii) x-ray interactions and data capture/conversion, (iii) acquisition/creation of the CT image, and (iv) operational details of a modern multislice CT scanner integrated with a PET scanner. Advances in PET technology have lead to widespread applications in diagnostic imaging and oncologic staging of disease. Combined PET/CT scanners provide the high-resolution anatomic imaging capability of CT with the metabolic and physiologic information by PET, to offer a significant increase in information content useful for the diagnostician and radiation oncologist, neurosurgeon, or other physician needing both anatomic detail and knowledge of disease extent. Nuclear medicine technologists at the forefront of PET should therefore have a good understanding of x-ray imaging physics and basic CT scanner operation, as covered by this 4-part series. After reading the first article on x-ray production, the nuclear medicine technologist will be familiar with (a) the physical characteristics of x-rays relative to other electromagnetic radiations, including gamma-rays in terms of energy, wavelength, and frequency; (b) methods of x-ray production and the characteristics of the output x-ray spectrum; (c) components necessary to produce x-rays, including the x-ray tube/x-ray generator and the parameters that control x-ray quality (energy) and quantity; (d) x-ray production limitations caused by heating and the impact on image acquisition and clinical throughput; and (e) a glossary of terms to assist in the understanding of this information.

Humans↗

Dose reduction in pediatric CT: a rational approach.

PURPOSE: To determine size-dependent technique factors for pediatric computed tomography (CT) by using physically measured objective data. MATERIALS AND METHODS: Six phantom cylinders (10-32 cm in diameter) were scanned with a clinical multi-detector row CT scanner. CT noise was statistically characterized for CT technique factors from 80 to 140 kVp and from 10 to 300 mAs. Dose measurements were performed with each phantom. Dilute iodine and tissue contrast were determined with computer calculations validated with measured data. The dose, noise, and contrast data were computer fit, and pediatric CT technique factors (milliampere seconds) necessary to maintain the contrast-to-noise ratio (CNR) were computed. RESULTS: As compared with that in a reference cylindric adult abdomen of 28 cm in diameter, CNR was maintained at a constant level in pediatric patients of 25, 20, and 15 cm in diameter, respectively, when milliampere second values of 0.557, 0.196, and 0.054 of the adult milliampere second values were used. The corresponding doses were reduced to 0.642, 0.287, and 0.090 of the 28-cm-diameter adult dose, respectively. CT techniques for examination of pediatric heads measuring 15 and 13 cm, respectively, can involve the use of milliampere second values of 0.572 and 0.366 of those used for examination of a standard 17-cm-diameter adult head. CONCLUSION: CT technique charts for pediatric abdominal and head examinations were produced on the basis of physically measured data; use of these tables will enable pediatric radiation dose to be reduced while CNR is preserved.

Adult↗

Grid and slot scan scatter reduction in mammography: comparison by using Monte Carlo techniques.

PURPOSE: To evaluate a comprehensive array of scatter cleanup techniques in mammography by using a consistent methodology. MATERIALS AND METHODS: Monte Carlo techniques were used to evaluate the Bucky factor (BF) and the contrast improvement factor (CIF) for linear and cellular grids and for slot scan and scanning multiple-slot assembly (SMSA) systems. RESULTS: For a 28-kVp molybdenum anode-molybdenum filter spectrum with a standard detector and a 6-cm-thick 50% adipose-50% glandular breast phantom, slot scan techniques delivered an ideal BF. For slot widths greater than 4 mm, however, the CIF was lower than that achieved by the high-transmission cellular grid with a grid ratio of 3.8:1. A tungsten-septa air-interspaced cellular grid with a 4:1 grid ratio outperformed the high-transmission cellular grid in both BF and CIF. The SMSA was shown to be efficacious when 4-mm-wide slots were separated by at least 20 mm. In comparison with the literature, 3.6% agreement was achieved with other Monte Carlo studies, 3.3% with an experimental study that used a digital detector, and 13%-29% agreement was demonstrated in comparison to film-based experimental studies. CONCLUSION: With use of consistent methods for comparison, cellular grids were shown to substantially outperform linear grids but have slightly higher BFs compared with that of slot scan geometries at the same CIF.

Mammography↗

AAPM/RSNA tutorial on equipment selection: PACS equipment overview: general guidelines for purchasing and acceptance testing of PACS equipment.

A picture archiving and communication system (PACS) is a comprehensive computer system that is responsible for the electronic storage and distribution of medical images in the medical enterprise. The system is highly integrated with digital acquisition and display devices and is often related closely to other medical information systems, such as the radiology information system or hospital information system. In the past few years, there has been continuous growth in clinical implementation of PACS to reduce costs and improve patient care, a trend that is expected to continue. However, a PACS is complex and costly to acquire, replace, maintain, and repair. To select a system that best meets their requirements, purchasers of PACS equipment need to be aware of the key characteristics and differing features of the various products. After the PACS has been installed, the user should perform technical and clinical acceptance testing to ensure that the system meets expectations.

Data Display↗

Determining sensitivity of mammography from screening data, cancer incidence, and receiver-operating characteristic curve parameters.

OBJECTIVES: A mathematical model is presented that allows the computation of the sensitivity and specificity of breast screening based on receiver-operating characteristic (ROC) curve shape, the positive predictive value (PPV) of screening mammography, and the cancer incidence, f. METHODS: The normal and cancer populations are modeled as normal distributions with independent means and standard deviations. The distributions are scaled such that the area of the normal population is equal to 1-f and that of the cancer population is f. The PPV for screening mammography is used to determine the operating point on the ROC curve. Knowing this leads directly to the computation of sensitivity and specificity. The derivation is general and is applicable to both symmetrical and asymmetrical ROC curves. RESULTS: For symmetric ROC curves and typical values for the PPV of mammography (about 8%) and cancer incidence (f= 0.003), an A(z) value of 0.95 was required to achieve 63% sensitivity and an A. value of 0.98 led to 86% sensitivity. CONCLUSION: A model was developed that should allow researchers to deduce sensitivity and specificity for screening mammography based on ROC curve measurements and using realistic values of PPV and f. This model allows A. values to be related to the probability of breast cancer detection.

Breast Neoplasms↗