PubMed Health⌕ Search

Biomedical subjects

J Areeda

Publications and source records attributed to J Areeda.

12 recordsLinked to original sources

Quantitative analysis of regional motion and thickening by gated myocardial perfusion SPECT: normal heterogeneity and criteria for abnormality.

UNLABELLED: Quantitation of regional myocardial function is valuable in patients with coronary artery disease. This study assessed normal heterogeneity and developed and validated normal limits for quantitative regional motion and thickening by gated myocardial perfusion SPECT. METHODS: Patients underwent rest (201)Tl/exercise (99m)Tc-sestamibi gated SPECT. Reference values of motion and thickening for 20 myocardial segments were obtained in 105 patients with <5% likelihood of coronary disease (low-likelihood group). Criteria for abnormality of motion and thickening were defined for each segment, using receiver operator characteristic analysis, in 101 patients with coronary disease (training group). Semiquantitative visual interpretation was used as the gold standard. These criteria were prospectively validated in 100 patients (validation group). Criteria for grading motion and thickening abnormalities by severity levels were also defined and validated. RESULTS: Normal thickening decreased substantially along the longitudinal axis of the left ventricle, from 69% +/- 13% at the apex to 25% +/- 11% at the basal segments, whereas normal motion varied within the same ventricular plane. Validation of the criteria for abnormality yielded high accuracy in the detection of motion abnormalities (sensitivity, 88%; specificity, 92%) and thickening abnormalities (sensitivity, 87%; specificity, 89%). Quantitative motion and thickening segmental scores showed good agreement with visual scores. CONCLUSION: Normal regional myocardial contraction by gated myocardial perfusion SPECT is characterized by a substantial apex-to-base decline in thickening and by circumferential heterogeneity in endocardial motion. The assignment of segment-specific threshold values for defining motion and thickening abnormalities provided reasonably accurate identification and grading of regional myocardial dysfunction.

Aged↗

A new algorithm for the quantitation of myocardial perfusion SPECT. I: technical principles and reproducibility.

UNLABELLED: We have developed a new, completely automatic 3-dimensional software approach to quantitative perfusion SPECT. The main features of the software are myocardial sampling based on an ellipsoid model; use of the entire count profile between the endocardial and epicardial surfaces; independence of the algorithm from myocardial shape, size, and orientation and establishment of a standard 3-dimensional point-to-point correspondence among all sampled myocardial regions; automatic generation of quantitative measurements and 5-point semiquantitative scores for each of 20 myocardial segments and automatic derivation of summed perfusion scores; and automatic generation of normal limits for any given patient population on the basis of data fractionally normalized to minimize hot spot artifacts. METHODS: The new algorithm was tested on the tomographic images of 420 patients studied with a rest 201TI (111-167 MBq, 35 s/projection)-stress 99mTc-sestamibi (925-1480 MBq, 25 s/projection) separate dual-isotope protocol on a single-detector camera, a dual-detector 90 degrees camera, and a triple-detector camera. RESULTS: The algorithm was successful in 397 of 420 patients (94.5%) and 816 of 840 image datasets (97.1%), with a statistically significant difference between the success rates of the 201TI images (399/ 420, or 95.0%) and the 99mTc images (417/420, or 99.3%; P < 0.001). Algorithm failure was caused by extracardiac uptake (10/24, or 41.7%) or inaccurate identification of the valve plane because of low count statistics (14/24, or 58.3%) and was obviated by simply limiting the image volume in which the software operates. Reproducibility of measurements of summed perfusion scores (r = 0.999 and 1 for stress and rest, respectively), global defect extent (r = 0.999 and 1 for stress and rest, respectively), and segmental perfusion scores (exact agreement = 99.9%, kappa = 0.998 for stress and 0.997 for rest) was extremely high. CONCLUSION: Automatic 3-dimensional quantitation of perfusion from 201Tl and 99mTc-sestamibi images is feasible and reproducible. The described software, because it is based on the same sampling scheme used for gated SPECT analysis, ensures intrinsically perfect registration of quantitative perfusion with quantitative regional wall motion and thickening information, if gated SPECT is used.

Algorithms↗

Comparative prognostic value of automatic quantitative analysis versus semiquantitative visual analysis of exercise myocardial perfusion single-photon emission computed tomography.

OBJECTIVES: The purpose of this study was to determine the prognostic value of automatic quantitative analysis in exercise dual-isotope myocardial perfusion single-photon emission computed tomography (SPECT) and to compare the prognostic value of quantitative analysis to semiquantitative visual SPECT analysis. BACKGROUND: Extent, severity and reversibility of exercise myocardial perfusion defects have been shown to correlate with prognosis. However, most studies examining the prognostic value of SPECT in chronic coronary artery disease (CAD) have been based on visual analysis by experts. METHODS: We studied 1,043 consecutive patients with known or suspected CAD who underwent rest Tl-201/exercise Tc-99m sestamibi dual-isotope myocardial perfusion SPECT and were followed up for at least 1 year (mean 20.0+/-3.7 months). After censoring 59 patients with early coronary artery bypass grafting or percutaneous transluminal coronary angioplasty, <60 days after nuclear testing, the final population consisted of 984 patients (36% women, mean age 63+/-12 years). RESULTS: During the follow-up period, 28 hard events (14 cardiac deaths, 14 nonfatal myocardial infarctions) occurred. Patients with higher defect extent (>10%), severity (>150) and reversibility (>5%) by quantitative SPECT defect analysis, as well as those with an abnormal scan (>2 abnormal segments, summed stress score >4 and summed difference score >2) by semiquantitative visual SPECT analysis, had a significantly higher hard event rate compared to patients with a normal scan (p < 0.001). With both visual and quantitative analyses, hard event rates of approximately 1% with normal scans and 5% with abnormal scans (p > 0.05) were observed over the 20-month follow-up period. A Cox proportional hazards regression model showed that chi-square increased similarly with the addition of quantitative defect extent and visual summed stress score variables after considering both clinical and exercise variables (improvement chi-square = 11 for both, p < 0.0007). There were no significant differences in the areas under receiver operating characteristic curves between quantitative and visual analysis (p > 0.70). Linear regression analysis also indicated that quantitative assessments correlated well with visual semiquantitative assessments. CONCLUSIONS: The findings of this study indicate that automatic quantitative analysis of exercise stress myocardial perfusion SPECT is similar to semiquantitative expert visual analysis for prognostic stratification. These findings may be of particular clinical importance in laboratories with less experienced visual interpreters.

Aged↗

Clinical validation of automatic quantitative defect size in rest technetium-99m-sestamibi myocardial perfusion SPECT.

UNLABELLED: We examined the relationships of automatic quantitative perfusion defect size and defect severity to rest left ventricular ejection fraction and semiquantitative visual sestamibi defect size in rest 99mTc-sestamibi SPECT in 40 consecutive patients with a history of myocardial infarction more than 30 days prior to testing. The purpose of this investigation was to validate the use of automatic quantitative rest sestamibi SPECT as a clinical measure of assessing relative infarction size. METHODS: All patients received 20-30 mCi of 99mTc-sestamibi followed by SPECT imaging. Quantitative defect analysis used previously developed resting normal limits and an automatic version of a commercially available quantitative program (CEqual). Semiquantitative visual defect interpretation used a 20 segment/scan and five-point scoring analysis. First-pass (FP) radionuclide ventriculography (RVG) and gated sestamibi perfusion SPECT were each performed in 31 patients. RESULTS: LVEF assessed by FP RVG was 37% +/- 15% (range 14%-62%) and 37% +/- 16% (range 12%-63%) by gated perfusion SPECT with high linear correlation (r = 0.96, n = 22) between the two methods. Myocardial perfusion defect size was 24% +/- 15% of LV (range 0%-50%) and defect severity was 1103 +/- 864 (range 0 to 2825) by automatic quantitative rest sestamibi. Perfusion defect size and defect severity both had close correlations with LVEF by FP RVG (r = -0.78, r = -0.86) and by gated perfusion SPECT (r = -0.75, r = -0.79). High linear correlations were observed between quantitative defect size and summed visual score of segments with score > or = 2 (r = 0.82) and the number of visually abnormal segments (r = 0.77), as well as between defect severity and visual summed rest score (r = 0.86) and the number of visually abnormal segments (r = 0.76). CONCLUSION: Quantitation of rest sestamibi SPECT defect extent and severity using automatic CEqual correlates well with rest LVEF and with semiquantitative expert visual analysis. Results of this study define a strong relationship between measurements of 99mTc-sestamibi perfusion defect as measured by an automatic software program and global left ventricular function. The automatic quantitative program appears to be a useful measure of assessing infarct size in patients with remote myocardial infarction.

Adult↗

Multicenter trial validation for quantitative analysis of same-day rest-stress technetium-99m-sestamibi myocardial tomograms.

UNLABELLED: The accuracy of an automated quantitative analysis of same-day rest/stress 99mTc sestamibi SPECT images for detection and localization of coronary artery disease (CAD) was assessed in a multicenter trial consisting of 161 patients from 7 different clinical sites utilizing various camera computer systems. METHODS: Of the 161 patients, 102 had angiographically documented coronary artery disease, 22 had normal coronary arteriograms, and 37 had a low (< 5%) likelihood of coronary artery disease based on their age, sex, symptoms and the results of their exercise electrocardiograms. The patients were studied using previously optimized image acquisition and processing protocols. An additional population consisting of 45 patients with single-vessel disease were evaluated to determine the optimal criteria for detection of CAD. RESULTS: The quantitative analysis method was associated with an overall sensitivity of 87%, specificity of 36%, and normalcy rate (true negative rate in the low likelihood patients) of 81%. Sensitivity for overall detection of disease was similar (90%) in patients with and without myocardial infarction (90% versus 89%). The sensitivities and specificities for identification of disease in individual coronary arteries were, respectively, 69% and 76% for LAD, 70% and 80% for LCX, and 77% and 85% for RCA. CONCLUSION: The results of this study demonstrate that the new objective quantitative method for analysis of same-day rest/stress 99mTc sestamibi SPECT images is accurate for detection and localization of CAD and correlates highly with expert visual interpretation.

Adolescent↗

Quantitative same-day rest-stress technetium-99m-sestamibi SPECT: definition and validation of stress normal limits and criteria for abnormality.

Gender-matched stress normal limits and criteria for abnormality for rest-stress 99mTc-sestamibi same-day myocardial perfusion imaging were developed and validated in 160 patients who were imaged using previously developed optimized acquisition, processing and quantitative protocols. The gender-matched mean and standard deviation of the normal response were calculated using 35 male and 25 female patients with a < 5% likelihood of coronary artery disease. Receiver-operating curve analysis using expert visual interpretation as the "gold standard" was used to determine the optimal criteria for abnormality detection, in terms of standard deviations from the mean and minimum defect size for each of the four major zones of the polar map, in a pilot population consisting of an additional 35 male and 25 female patients with a variety of perfusion defects. The optimum standard deviations resulted in the following true-positive/true-negative rates when quantitative results were compared to visual analysis for the anterior, septal, lateral, and inferior segments in the combined male and female pilot populations: 84%/86%, 70%/75%, 86%/76% and 69%/76%, respectively. The final criteria were then applied to a prospective population consisting of 33 male and 7 female patients. This analysis resulted in the following true-positive/true-negative rates for overall perfusion abnormalities and abnormalities of the LAD, LCX and RCA vascular territories: 97%/67%, 94%/73%, 73%/90% and 72%/91%, respectively. The optimized 99mTc-sestamibi stress normal limits and criteria for abnormality correlate well with expert visual interpretation of stress myocardial perfusion defects.

Coronary Disease↗

Preservation of regional myocardial ultrasonic backscatter and systolic function during brief periods of ischemia by synchronized coronary venous retroperfusion.

This study examines the effects of brief periods of ischemia on average and cardiac cycle-dependent variation of regional ultrasonic backscatter paralleled with changes in regional myocardial contraction, and to what extent these changes could be reversed by synchronized coronary venous retroperfusion. In five closed-chest dogs, the left anterior descending coronary artery was occluded on four occasions for a 2-minute period and retroperfusion was applied randomly to two of the coronary occlusions. Complete functional recovery was allowed between the occlusions. Two-dimensional echocardiographic images were obtained before and at the peak of the 2-minute occlusion period. Regional myocardial contraction as measured by fractional area change and systolic wall thickening during untreated occlusions decreased from 33.9 +/- 14.0% to -0.15 +/- 6.2%, and from 22.0 +/- 1.8% to -17.9 +/- 2.2%, whereas during retroperfusion-treated occlusions it changed from 37.4 +/- 8.5% to only 23.4 +/- 11.2% (p less than 0.005 versus baseline), and from 24.1 +/- 2.8% to only 12.7 +/- 2.0% (p less than 0.005 versus baseline), corresponding to a preservation of 62% and 52% of baseline regional contraction, respectively. Average regional gray level (arbitrary units) during untreated coronary occlusions exhibited a significant increase in the ischemic regions, from 5.6 +/- 2.7 at baseline to 11.5 +/- 4.4 during occlusion (p less than 0.005); during retroperfusion-treated occlusions, average gray level increased from 4.7 +/- 3.6 to only 6.3 +/- 3.6 (NS). Untreated coronary artery occlusions resulted in a systolic increase in gray level in the ischemic region, followed by a diastolic decrease.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Reversal of chronic regional myocardial dysfunction (hibernating myocardium) by synchronized diastolic coronary venous retroperfusion during coronary angioplasty.

A 62 year old man with previous myocardial infarction, an occluded right coronary artery and a 90% stenosis of the left anterior descending coronary artery underwent angioplasty with the support of coronary venous retroperfusion of arterial blood during the procedure. In two of four angioplasty balloon dilations of the left anterior descending coronary artery, synchronized diastolic retroperfusion of the coronary veins with arterial blood was applied to protect the severely dysfunctioning myocardium from additional ischemia. Two-dimensional echocardiography was used to monitor and quantitate alterations in left ventricular function. Retroperfusion of arterial blood resulted in immediate improvement in ischemic zone wall motion despite the totally occluded artery during balloon dilation. Echocardiographic images recorded after angioplasty showed a marked improvement in contraction of the previously dyskinetic segments, with changes similar to those seen during balloon dilations with synchronized diastolic coronary venous retroperfusion. Thus, in this patient, viability of chronically dysfunctioning myocardium could be demonstrated by the improvement in regional wall motion during retroperfusion. This technique could eventually be of value to elucidate the anatomic location of viable myocardium while maintaining adequate left ventricular systolic function during coronary artery interventions in the catheterization laboratory.

Angioplasty, Balloon, Coronary↗

Quantitative analysis of tomographic stress thallium-201 myocardial scintigrams: a multicenter trial.

The accuracy of the previously developed and validated Cedars-Sinai Medical Center (CSMC) computer program for quantitative analysis of thallium-201 (201TI) stress myocardial tomograms was assessed in a multicenter trial consisting of 242 patients with coronary angiography and 76 with a low likelihood (LL) of coronary artery disease (CAD) involving various cameras, computers, and operators. The program utilized gender-matched normal limits developed from 35 LL patients at CSMC. The multicenter results as compared to those of 168 patients from CSMC were not significantly different with respect to the overall sensitivities (94% versus 95%) and specificities (44% versus 56%) for identification of CAD and normalcy rates which were determined in LL patients (82% for both) and with respect to identification of individual diseased arteries. The results indicate that our method for quantifying tomographic 201TI stress scintigrams utilizing standard normal limits can be applied at other institutions by different operators, using a variety of cameras and computers, with similar accuracy to that currently obtained at our institution.

Coronary Disease↗

Echocardiographic criteria to distinguish reversible from irreversible myocardial ischaemia.

This treatise reviews two-dimensional echocardiographic criteria which have been developed to describe and distinguish reversible vs irreversible myocardial ischaemia. It also discusses the new pathophysiologic concepts such as 'hibernating' and 'decapitated' myocardium, and also 'reperfusion injury' and 'stunned' myocardium, complications which may supervene following reperfusion of jeopardized ischaemic myocardium. Computerized regional and global wall-motion analysis is now usually measured from enhanced endocardial edges. Provocative interventions can contribute information regarding viability of jeopardized ischaemic regions by testing contractile response of the myocardium to afterload reducing agents such as nitroglycerine or nitroprusside. They can also validate viability by demonstrating that post-extrasystolic beats can still cause potentiation. Ultrasonic contrast washout half-life of the myocardium which is compromised by stenotic coronary arteries provides a promising method for supplying information about the coronary perfusion defects and flow reserve. The decrease in global or regional ejection fraction following exercise echocardiography may show if jeopardized ischaemic myocardium is irreversibly damaged. A new hypercontractility phenomenon is described following brief coronary occlusions such as during percutaneous transluminal angioplasty, or after sudden release of angiospasm, and this should be considered a sign of viability. Increase in end-diastolic wall thickness and echo amplitudes immediately after reperfusion of ischaemic segments is often associated with reversibly damaged myocardium.

Coronary Disease↗

Quantification of rotational thallium-201 myocardial tomography.

A comprehensive method is described for quantification of the relative 3-dimensional distribution of Tl-201 in the myocardium, following stress and subsequent washout. The method uses maximal-count circumferential profiles of well-defined long- and short-axis tomograms to determine the 3-dimensional distribution of Tl-201; it then maps this distribution onto a 2-dimensional polar representation. Abnormal thallium distribution or washout is identified by automatic computer comparison of each patient's profile with the corresponding lower limits of normal profiles. Abnormality is expressed as a percentage of the entire myocardium by use of polar maps for extent and severity. The binary extent map expresses the degree of abnormality. Preliminary criteria for abnormality were derived from the tomographic results of 25 normals and 28 patients with documented coronary artery disease. The results were normal in 23 of the 25 normals and were abnormal in 25 of the 28 CAD patients. In addition, the computer output correctly localized the presence or absence of disease in 46 of 56 coronary circulations.

Adult↗

Physical factors influencing quantitation of two-dimensional contrast echo amplitudes.

Measurement errors that may interfere with quantitation by the new myocardial contrast two-dimensional echocardiographic technique were examined in a simplified in vitro model consisting of a 50 cc blood-filled balloon with supplemental controlled injection of 0.2 to 2.6 cc of sonicated dextrose 70%. The blood-contrast mixture in the balloon volume was imaged with two-dimensional echocardiography and discrete regions were studied for both magnitude and time course of echo intensities. Preliminary evidence indicates that a regional contrast echo intensity measurement is significantly modified by contrast-related ultrasound attenuation in intervening regions and by the amount and mode of contrast material injection. Thus, injection of 1.2 cc contrast material resulted in substantially higher peak echo intensity and a more rapid decay than injection of 0.8 or 0.6 cc. These measurements were also found to be influenced by the echographic system signal processing and time-gain compensation which contribute to nonlinear and unevenly compensated image distribution of echo amplitudes. Other factors are discussed, including transducer-related image resolution and image texture, contrast agent bubble size and persistence and computer methods for standardized selection of region of interest and analysis of the regional contrast intensity decay curve.

Blood↗