PubMed Health⌕ Search

Biomedical subjects

J Awad

Publications and source records attributed to J Awad.

86 records · Page 5Linked to original sources

Preclotting of knitted Dacron prosthesis. A scanning electron microscope study.

A scanning electron microscope study of preclotting on knitted Dacron prosthesis is reported. Five steps of the interaction are well identified: (1) before any blood contact (virgin Dacron), (2) during the first 3 minutes (fibrin and platelet aggregates), (3) fifth minute of contact (clotting), (4) 15 minutes of contact with heparinized blood (thin fibrin network), and (5) the following minutes (invasion of fibrin, which enmeshes blood cells).

Adult↗

New HLA DNA polymorphisms associated with autoimmune diseases.

Certain class II determinants of the human histocompatibility locus antigens (HLA) have been implicated in the aetiology of several autoimmune diseases, including rheumatoid arthritis (RA) and insulin-dependent diabetes mellitus (IDDM). HLA-Dw4 was the first HLA determinant found to be significantly increased in RA patients compared with controls, while Dw4 and Dw3 were found to be significantly increased in IDDM patients. When the HLA-DR system was defined, RA patients were found to have an increased frequency of DR4 and IDDM patients an increased incidence of both DR4 and DR3 compared with controls. As the HLA-Dw specificities are narrower than the serologically defined DR specificities, it was of specific interest to the present study that Dw4, Dw10, Dw13, Dw14, Dw15 and DKT2 are included in DR4. We describe here new restriction fragment length polymorphisms (RFLPs) and, together with the newly described serologically defined DQ specificity TA10, test their prevalence and associations in controls and diseased patients. We find that the newly characterized DNA bands are present at a much higher frequency in RA and IDDM patients than in controls. These findings may lead to a greater understanding of the pathogenesis of such diseases.

Arthritis, Rheumatoid↗

The benefits of fluoropassivation of polyester arterial prostheses as observed in a canine model.

The effect of treating the surface of a polyester vascular prosthesis with a novel fluoropolymer before sealing the graft with gelatin has been evaluated in a canine thoracoabdominal bypass model. The healing behavior of the Fluoropassiv graft was compared with that of the Gelsoft ERS prosthesis used as control for prescheduled periods of implantation ranging from 4 hr to 6 months. Both series of explanted grafts were analyzed using macroscopic, histologic, and scanning electron microscopic observations, and by determining the prostacyclin/thromboxane A2 ratio (PGI2/TXA2) and the thrombogenicity of the luminal surface by means of labelled platelets and fibrin deposition. Chemical analysis of explanted and cleaned graft segments was performed using electron spectroscopy for chemical analysis, differential scanning calorimetry, and contact angle methods. No difference in platelet and fibrin deposition or PGI2/TXA2 secretion by the luminal surface was observed between the treated and the control grafts at any implantation period. On the other hand, pathologic investigation has revealed that, although there is no difference between the two grafts during the first month, the healing sequence of the Fluoropassiv graft appeared more complete and mature than the control graft after 3 and 6 months. Differences were observed in the extent of collagenous internal capsular development, endothelialization, and tissue penetration into the knitted structure. The presence of fluorine and a higher contact angle at the surface of all the explanted fluoropassivated grafts is believed to have been responsible for reducing the inflammatory response and enhancing the long-term healing behavior of this novel prototype device over the control gelatin sealed prosthesis.

Animals↗

HLA class I and class II antigen associations in acute leukaemias.

HLA-A,B,C and DR antigen frequencies were determined in a group of 188 patients suffering from acute myeloid (AML) and acute lymphoid leukaemia (ALL). These antigen frequencies were compared with those obtained on a panel of normal individuals (n = 109) of the same ethnic origin. The significance of the differences in the antigen distribution and the strength of the associations between particular HLA antigens and the disease were then calculated. The results obtained show a decreased frequency of HLA-Aw19 in the overall group of patients and the group of patients with ALL. In addition, the antigen frequency of the HLA-B18 and DR5(DRw11) antigens was also decreased in the overall group of patients and in those patients with AML but not in the patients with ALL. The results suggest that the antigen Aw19 may confer some degree of resistance to the development of ALL and that the HLA-B18 and/or DR5 antigens may be resistance factors for the development of AML.

Adolescent↗

HLA and celiac disease in Argentina: involvement of the DQ subregion.

A population of 62 unrelated homogeneous Argentinian celiac pediatric patients were typed for HLA-A,B,C,DR, and DQ antigens. The association between celiac disease and the DR3 and DR7 antigens was confirmed. The specificity DQw2 was present in 95.2 per cent of the patients. Nevertheless, it was of interest that the most significant phenotypes observed were DR3/DR7, DR7/DR5, and DR3/DR5. The significance of these findings is discussed.

Alleles↗

[Glutaraldehyde - fixed human umbilical cord vein as a small diameter arterial substitute. Experimentation on the monkey].

Autologous saphenous veins, the preferred substitute material for aorto-coronary, femoro-popliteal and femoro-tibial by-pass, are usable in only 70% of individuals in need of such procedures. The development of small diameter substitute arteries is therefore essential to broaden the pool of patients who could benefit from this class of cardiovascular surgery. Existing substitutes, however, present major difficulties and have had limited success. In this laboratory, an attempt has been made to develop a vessel of 3 millimetres or less in diameter derived from human umbilical cord processed in glutaraldehyde. This substitute can be stored in 45% ethanol or dessicated by critical point drying. This device had been implanted as a segment of abdominal aorta in eight primates (Macaca fascicularis). Preliminary results are disappointing. The indicate that retention of a patency for more than a year post-implantation is difficultly achievable and that connective tissue hyperplasia leading to occlusion at the anastomoses is a major problem. Similar but larger diameter by-passes in the order of 6-8 millimetres should be investigated in greater detail, in order to better establish the "in-vivo" behavior of this class of tissue prosthesis. This would address the more fundamental issues pertaining to the clinical usefulness of fixed biological tissue by-pass devices.

Animals↗