Alteration of retrieved implants in vitro by processing and infiltrating fluids.

Undecalcified histology has proved of immense value in the examination of the interface membrane between the prosthesis and bone. However, to provide such histological sections, dehydrating and clearing fluids as well as plastic infiltrating fluids must be used. This study investigates the possibility that some of these commonly used fluids may alter the biomaterial after removal from the body and be misinterpreted as an in vivo product. Ten different routinely used fluids were tested on 11 different biomaterials that are commonly used in prosthetic devices. The nonmetal biomaterials were placed in glass tubes containing the different fluids at room temperature for 5 days. The biomaterials were assessed for changes each day. After 5 days the biomaterial was examined and discarded and the glass tube was centrifuged. The pellet was examined using polarized light microscopy. Polysulfone and bone cement was found to be considerably altered in vitro by most of these fluids. While the components (plasticizer and catalyst) of the plastic fluids caused some changes to the biomaterial. Spurr's and GMA did not cause any alterations to any of the biomaterials that were examined.

Biocompatible Materials

A hydrogel pericardial patch.

Patients undergoing repeat cardiac operations are higher operative risks than those undergoing an initial cardiac procedure because adhesion formation can occur if the native pericardium is not closed. A unique composite patch that may be used to augment the pericardial tissue when primary closure is not possible has been developed. The patch is made of a hydrogel, poly (2-hydroxyethyl methacrylate), reinforced with an ethylene tetrafluoroethylene (ETFE) mesh. The mesh provides the needed mechanical properties, whereas the patch's surface properties are comparable to the hydrogel. Two types of patches were fabricated: one with the mesh weave at a perpendicular orientation and one at 45 degrees to the principle loading direction. The patches were mechanically tested and compared with canine pericardium. Ultimate tensile strength of the patches is not significantly different from canine pericardium (p less than 0.05), are the patch suture strength is nearly twice that of canine pericardium. The perpendicular patch is stiffer than canine pericardium, whereas the 45 degree patch is not (p less than 0.05). The 45 degree patch shows considerable promise as a pericardial substitute because it closely matches the properties native canine pericardium.

Animals