PubMed Health⌕ Search

Biomedical subjects

J B Meding

Publications and source records attributed to J B Meding.

At least 37 records · Page 2Linked to original sources

Comparison of the midvastus muscle-splitting approach with the median parapatellar approach in total knee arthroplasty.

A total of 100 patients having bilateral total knee replacements simultaneously were randomized prospectively--one knee having a vastus muscle-splitting approach and the other knee having a median parapatellar approach-to evaluate differences in lateral release, postoperative rehabilitation, ease of approach, and complications in total knee replacement surgery. There were 25 lateral releases on the muscle-splitting side and 26 on the median parapatellar side (P = .871). There were no differences in range of motion on day 2 or discharge, straight-leg raise, terminal knee extension, extensor lag, lateral release, or rehabilitation. There were 2 postoperative hematomas and 1 manipulation, all on the muscle-splitting side. All complications occurred from the muscle-splitting side. The muscle-splitting approach cannot be recommended as being superior to the median parapatellar approach.

Adult↗

The clinical significance of proximal tibial resection level in total knee arthroplasty.

Clinical and radiographic data were collected in 139 patients with 195 posterior cruciate retaining total condylar knee prostheses to evaluate the relationship of the proximal tibial resection level with long term results. Among the 139 patients were 75 patients with 106 total knee replacements observed for more than 8 years. All patients underwent biyearly routine examinations, including radiographs and clinical evaluations. The average medial tibial resection for the 139 patients with 195 total knee replacements was 2.95 mm, and in the subset of 75 patients (106 knees) observed for more than 8 years, it was 3.3 mm; both groups had a maximum of 14 mm. Sixty-three percent or 67 knees had medial resection levels of 3 mm or less. The average lateral tibial resection for the 195 knees was 5.48 mm and in the 106 knees was 5.71 mm, with a maximum of 22 mm. Fifty-one percent of 104 knees had lateral resection levels of 5 mm or less. Statistical analysis showed that there was no significant correlation between the level of proximal tibial resection and Knee Society knee score, range of motion, radiolucencies, or loosening or revision. These long term results suggest that minimal proximal tibial resection is not necessary for a successful arthroplasty, and problems associated with minimal resection, such as joint line elevation and thin polyethylene inserts, can be avoided.

Adult↗

Intra-articular morphine and/or bupivacaine after total knee replacement.

The postoperative analgesic effects of intra-articular injections of bupivacaine and/or morphine were examined prospectively in 437 patients who had total knee replacement for osteoarthritis. They were divided randomly into four groups. Group I received 10 mg of morphine (1 ml) and 9 ml of saline, group II received 10 ml of bupivacaine (2.5 mg/ml), group III received 10 ml of saline, and group IV received 10 mg of morphine (1 ml) and 9 ml of bupivacaine (2.5 mg/ml). All analgesics administered in the first 24 hours after operation were recorded. The patients rated their pain on the McGill-Melzack scale at 1, 6, 12 and 24 hours. No significant differences were found between any of the groups in the use of Demoral and/or Toradol in 24 hours, the length of stay in hospital or the pain rating at 1, 6, 12 or 24 hours. Patients in groups I and IV, whose injections included morphine, used significantly more morphine in the first 24 postoperative hours than did groups II or III.

Adult↗

Radiological factors influencing femoral and acetabular failure in cemented Charnley total hip arthroplasties.

We have made a retrospective review of 185 cemented Charnley total hip arthroplasties performed between 1970 and 1974 to determine the relationships between radiological variables and failure of the femoral and acetabular components. We measured the acetabular wear, the orientation of the cup, the thickness and consistency of acetabular and femoral cement mantles, radiolucency and femoral alignment. The mean follow-up was for 11.7 years. Femoral loosening was demonstrable radiologically in 15 hips (8.1%), ten (5.4%) of which were revised during the period of follow-up. Only when the first postoperative radiograph showed a thin cement mantle in Gruen zone 5 was there a significant association with failure of the femoral component. There were 12 loose acetabular components (6.5%), nine (4.8%) of which were revised. When the initial radiograph after operation showed radiolucency in DeLee and Charnley zone 1, the incidence of acetabular loosening was 28.21%. If such radiolucency was not present, the incidence of acetabular loosening was only 0.69%. Our findings emphasise the importance of careful cementing.

Acetabulum↗

Patellar complications (total knee arthroplasty). Effect of lateral release and thickness.

One thousand, one hundred forty-six Anatomic Graduated Component total knee arthroplasties performed between 1987 and 1989 were used to investigate the effects of patellar thickness alone or coupled with lateral retinacular release on initial patellar complications and maximal flexion. Lateral release was found not to be statistically significant regarding radiolucency, patellar prosthesis loosening, or an increase or decrease in flexion. However, total knee arthroplasties in which a lateral release was done, which either saved the superior lateral genicular artery or sacrificed the superior lateral genicular artery, were found to increase the incidence of initial patellar fractures and/or loosening (complications within 1 year) when compared with total knee arthroplasties in which a lateral release was not performed. There was no statistical difference in failure rates regarding fractures and/or loosening of the patella between lateral releases in which the superior lateral genicular artery was saved and the lateral releases in which the superior lateral genicular artery was sacrificed. A difference in postoperative patellar thickness compared with preoperative patellar thickness was found not to be significant to initial patellar fracture and/or loosening, patellar fracture alone, patellar loosening alone, radiolucency, the need for a lateral release, or to an increase or decrease in flexion. Lateral release and patellar thickness had no significant effect on patellar fracture and/or loosening.

Adult↗

Life expectancy after total hip arthroplasty.

A total of 3,807 patients undergoing total hip arthroplasty (THA) between the years 1970 to 1995 were evaluated for mortality. Patient age groups were designated in 10-year intervals as follows: age <40; 41-50; 51-60; 61-70; 71-80; age >80. The life expectancy estimate of the patients with THA was calculated by the Kaplan-Meier method, and that of the normal population was obtained from standard life-tables. Statistical significance was evaluated using 95% confidence limits. A significant difference in life expectancy was found in patient age groups >60 (61-70, 71-80, >80) demonstrating significantly higher survival rates among THA patients when compared with the normal population.

Adult↗

Predictors of transfusion risk in elective knee surgery.

Two hundred seventy-nine patients undergoing primary unilateral total knee replacement and 280 patients undergoing primary bilateral total knee replacements were reviewed retrospectively. Patients' height, weight, hemoglobin level before donation, hemoglobin level before surgery, autologous donation, number and type of transfusions whether autologous or allogeneic, and hemoglobin at discharge were collected from hospital and clinic records. The average drop in hemoglobin was 3.85 g/dL in the group of patients undergoing unilateral total knee replacement and 5.42 g/dL in the group of patients undergoing bilateral total knee replacements. The preoperative hemoglobin and blood volume seemed to be very strong, statistically significant predictors of transfusion risk in single and bilateral knee replacements. In unilateral total knee replacement, patients with a hemoglobin of greater than 13 g/dL had only an 8% chance of transfusion and if they donated autologous blood, 66% of the blood was wasted. Preoperative anemia was a strong predictor of transfusion risk in patients undergoing unilateral and bilateral total knee replacements and carried a very high allogeneic transfusion exposure risk, even in patients who had donated blood preoperatively. A nomogram was developed using blood volume and predonation hemoglobin to predict transfusion risk and need to predeposit autologous blood in patients undergoing unilateral and bilateral total knee replacements.

Aged↗

Maximizing cost-effectiveness while minimizing complications in total hip replacement.

Between July 1989 and June 1994, a consecutive series of 651 cemented total hip arthroplasties were performed in 577 patients using relatively inexpensive implants and standardized surgical and postoperative protocols. We set out to determine what effect these cost-saving measures have on the overall success and complication rate after total hip replacement surgery. Surgical results remained excellent, and perioperative, early, and late complications, including infection, loosening, and revision hip surgery, remained minimal, indeed, below usual complication rates. We concluded that cost-effective measures can be implemented while maintaining the overall excellent results of hip replacement surgery without the risk of increasing complication rates.

Adult↗

Comparison of collared and collarless femoral components in primary uncemented total hip arthroplasty.

Two hundred three consecutive primary uncemented total hip arthroplasties were prospectively randomized using collared and collarless versions of an identical titanium stem. Identical 28-mm titanium heads were implanted in all cases. One hundred three collared hips were compared with 100 collarless hips. Follow-up periods averaged 45.7 months in both groups. Intraoperative, early, and late complications were similar. Hip scores, including thigh pain, at final follow-up visit were also similar. No significant differences were noted in acetabular or femoral radiolucencies, subsidence, osteolysis, or proximal femoral remodeling. At 5 years, more collarless stems revealed pedestal formation (57.1% vs 33.9%). The presence of a collar had no effect on the adequacy of fixation, proximal femoral osteopenia, or clinical scores at 5 years.

Adult↗

Total hip arthroplasty in patients with osteonecrosis. The effect of cement techniques.

One hundred fifteen patients who underwent total hip replacement for osteonecrosis between June 1972 and April 1990 were divided into 3 groups according to the cause of the disorder: (1) osteonecrosis secondary to alcoholism (21 patients), (2) osteonecrosis secondary to hypersteroidism (29 patients), and (3) idiopathic osteonecrosis (65 patients). To determine the differences in short and long term arthroplasty failure rates, these 3 patient groups were compared with a group of 202 patients who received total hip replacement for osteoarthritis. Statistical analyses were carried out on the following definitions of failure: loosening of the acetabular component, loosening of the femoral component, and revision arthroplasty. Radiolucency and postoperative pain scores also were evaluated. A significant difference in the rate of failure because of loosening of the femoral component was found among the 4 groups. Likewise, a significant difference was found among the 4 groups in all revisions or loosenings or both. However, only the comparison between the idiopathic osteonecrosis and osteoarthritic groups showed a significant difference with survival analysis. Second generation cement technique was as significant as any variable relating to failure. The authors conclude that total hip arthroplasty is an equally viable treatment for the 3 types of osteonecrosis examined in this study; however, failure might be more imminent in studies where larger numbers are needed.

Aged↗

Impaction bone-grafting before insertion of a femoral stem with cement in revision total hip arthroplasty. A minimum two-year follow-up study.

Impaction bone-grafting was performed before insertion of a collarless, polished, tapered femoral stem with cement in thirty-four revision total hip arthroplasties (thirty-four patients) that were done because of aseptic loosening. The average duration of follow-up was thirty months (range, twenty-four to forty-two months). The operation was the initial revision in twenty-eight patients (82 per cent). Twenty-two patients (65 per cent) also had revision of the acetabular component. Complications included four intraoperative and two postoperative fractures of the femur as well as one dislocation (at one month). Two patients (6 per cent) needed a repeat revision of the femoral stem because of aseptic loosening at twenty-six and thirty-six months postoperatively. Both of these patients had an associated fracture of the femur (one was intraoperative, and the other was postoperative). Subsidence was common (thirteen patients; 38 per cent) and averaged 10.1 millimeters (range, four to thirty-one millimeters). Although the study group was relatively small, with the numbers available subsidence was not found to be associated with the preoperative or postoperative hip score, segmental or cavitary femoral defects, femoral ectasia, intraoperative fracture of the femur, strut-grafting, trochanteric osteotomy, or varus position of the femoral component. Incorporation of the allograft into the trabecular bone and secondary remodeling were noted radiographically in thirty-two (94 per cent) and fourteen (41 per cent) of the patients, respectively, often within one year. Although the duration of follow-up was relatively short, no localized resorption of the allograft occurred and cortical repair was noted in one patient at three years. At the most recent follow-up evaluation, the Harris hip scores had improved from a preoperative average of 51 points (range, 32 to 90 points) to an average of 87 points (range, 65 to 100 points) and twenty-eight patients (82 per cent) had no or only slight pain. Despite the satisfactory early clinical results, we remain concerned about the high rate of fracture of the femur and the rate and extent of subsidence of the femoral component. On the basis of the worrisome findings after this two-year period, we recommend that impaction bone-grafting be used only when proximal femoral osteopenia is so severe that stability cannot be obtained with insertion of a long-stemmed femoral component without cement. In that setting, impaction bone-grafting may be considered instead of implantation of a massive proximal femoral allograft in combination with insertion of a femoral component with cement.

Adult↗

Radiographic analysis of a cemented titanium alloy femoral component.

Proximal femoral cortical bone remodeling was evaluated radiographically about a 1 piece cemented titanium alloy femoral prosthesis implanted with modern cement techniques and was compared with one described previously in which early cement techniques and a stainless steel stem were used. Two hundred twenty-six total hip replacements (196 patients) were observed for an average of 6.3 years (range, 5-10 years). Analysis of all hips revealed that the ratio of cortical thickness to that of the overall femoral bone diameter did not change significantly about the periprosthetic bone throughout the length of the study. Cortical hypertrophy and atrophy occurred at rates similar to those seen with the early cement techniques. Distal fusiform cortical hypertrophy and the formation of osteosclerotic (reactive) lines at the bone cement interface occurred at approximately half the rate using modern cement techniques. In addition, cortical atrophy was associated with the formation of these reactive lines, the occurrence of osteolytic lesions, and progressive bone cement interface radiolucencies. Although periprosthetic cortical atrophy occurred at rates similar to those reported previously, important differences were noted between the findings of this study and the earlier study; these differences most likely were a result of cement technique or the prosthesis.

Aged↗

Patellofemoral complications following total knee arthroplasty. Effect of a lateral release and sacrifice of the superior lateral geniculate artery.

Between 1987 and 1989, 1,205 Anatomic Graduated Component (AGC, Biomet, Warsaw, IN) total knee arthroplasties were performed by three surgeons using the same prosthesis and same technique. Four hundred twenty-eight total knee arthroplasties (35%) had lateral releases; in 107 (75%) of these, the superior lateral geniculate artery was saved. Lateral release had no effect on patellar subluxation, dislocation, or loosening, but was associated with significantly more patellar fractures. Conversely, patellar radiolucency was more common in knees without a lateral release. Furthermore, saving the superior lateral geniculate artery during a lateral release had no effect on patellar dislocation, radiolucency, loosening, or fracture.

Aged↗

Outcome of the contralateral hip following total hip arthroplasty for osteoarthritis.

One thousand one hundred and sixteen patients who underwent unilateral total hip arthroplasty osteoarthritis between 1970 and 1980 were examined for development, progression, and total hip arthroplasty in the contralateral joint. At the time of the original surgery, 452 patients were diagnosed with bilateral osteoarthritis and 664 had a normal contralateral hip. The probability of osteoarthritis progressing in the contralateral joint is 78.6% at 10 years, with the chance of arthroplasty being 53.8%. The probability of a hip diagnosed as normal developing osteoarthritis is 36.5% at 10 years, with an 8.3% chance of requiring total hip arthroplasty.

Adult↗

Tibial shaft fracture following tibial tubercle osteotomy.

Tibial tubercle osteotomy has been reported to be an excellent exposure for a very stiff primary or revision knee requiring total knee arthroplasty. In 1993, the Center for Hip and Knee Surgery performed 657 primary and 16 revision total knee arthroplasties, using tibial tubercle osteotomy in 9 cases, 2 of which sustained tibial shaft fractures, because of which the Center's experience is reviewed.

Aged↗

Femoral head size: variation among manufacturers.

Nine manufacturers were contacted for their specific femoral head diameters of the 22 mm, 28 mm, and 32 mm femoral components. The 22 mm heads averaged .869 in. (+/- .005) and 100% were within 1 standard deviation; however, the standard deviation was large. The 28 mm heads averaged 1.101 in. (+/- .002), and 89% were within 1 standard deviation. The 32 mm heads averaged 1.258 in. (+/- .002), and 78% were within 1 standard deviation. It seems that when a 28 mm or 32 mm femoral head is used, different femoral and acetabular components by different manufacturers can be intermixed. However, when changing a 22 mm femoral head, the manufacturer should possibly be notified and an attempt to use the same manufacturer is preferable.

Hip Prosthesis↗

Comparative outcomes of total joint arthroplasty.

A prospective pre- and postoperative general health/quality-of-life factor comparison, using the Rand SF-36 Health Status Questionnaire (TyPE Specification, Quality Quest [Health Outcomes Institute, Minneapolis, MN]), was carried out on a consecutive series of patients with diagnosed osteoarthritis undergoing total hip and knee arthroplasty between March 1991 and March 1994. Study groups consisted of 85 total hip arthroplasty patients, 93 total knee arthroplasty patients, and 65 single-stage bilateral total knee arthroplasty patients, all treated at the same specialty hospital, under the care of three senior orthopaedic surgeons. The average patient age was 69 years. Significant improvements in quality-of-life measures including physical functioning, social functioning, role functioning/physical problem, role functioning/emotional problem, mental health, energy/fatigue, pain, and change in health were noted in all hip and knee arthroplasty patients 6 months, 1 year, and 2 years after surgery (P < .05). There appeared to be no significant differences in quality-of-life measures between hip and knee arthroplasty patients. Results therefore indicate that total hip and knee arthroplasty significantly improve the functional status and quality of life among patients suffering from osteoarthritis.

Activities of Daily Living↗

Rush rod fixation of supracondylar fractures above total knee arthroplasties.

The authors report on 22 displaced supracondylar femur fractures and total knee arthroplasties treated with Rush rod (Berivon, Meridian, MI) fixation. The average age at the time of total knee arthroplasty was 67 years. Fractures occurred at an average of 5 years after surgery. In only five cases was notch in the anterior cortex noted. The follow-up period averaged 7 years. There were no nonunions. All knees healed between 3 and 4 months after surgery. Postoperative flexion averaged 108 degrees (preoperative average, 102 degrees). Only two knees demonstrated a flexion contracture before surgery (5 degrees-10 degrees), and both had flexion contractures after surgery as well (each 10 degrees). All other knees achieved full extension. The average alignment prior to fracture was 7 degrees of anatomic valgus. At the most recent follow-up evaluation this averaged 10 degrees with two knees in 15 degrees of valgus. The only complications noted were two intraoperative technical errors. No postoperative complications occurred. For supracondylar fractures above a total knee arthroplasty, the authors suggest closed reduction, Rush supracondylar rod fixation, early range of motion, and protected weight bearing until fracture healing. In all cases, an extensive surgical procedure was not required.

Aged↗