PubMed HealthSearch

Biomedical subjects

J B Morrison

Publications and source records attributed to J B Morrison.

At least 19 recordsLinked to original sources

Brain tissue pH and ventilatory acclimatization to high altitude.

31P nuclear magnetic resonance spectroscopy (31P-NMRS) was performed on brain cross sections of four human subjects before and after 7 days in a hypobaric chamber at 447 Torr to test the hypothesis that brain intracellular acidosis develops during acclimatization to high altitude and accounts for the progressively increasing ventilation that develops (ventilatory acclimatization). Arterial blood gas measurements confirmed increased ventilation. At the end of 1 wk of hypobaria, brain intracellular pH was 7.023 +/- 0.046 (SD), unchanged from preexposure pH of 6.998 +/- 0.029. After return to sea level, however, it decreased to 6.918 +/- 0.032 at 15 min (P less than 0.01) and 6.920 +/- 0.046 at 12 h (P less than 0.01). The ventilatory response to hypoxia increased [from 0.35 +/- 0.11 (l/min)/(-%O2 saturation) before exposure to 0.69 +/- 0.19 after, P = 0.06]. Brain intracellular acidosis is probably not a supplemental stimulus to ventilatory acclimatization to high altitude. However, brain intracellular acidosis develops on return to normoxia from chronic hypoxia, suggesting that brain pH may follow changes in blood and cerebrospinal fluid pH as they are altered by changes in ventilation.

Acclimatization

A computer-aided socket design procedure for above-knee prostheses.

A computer-aided socket design procedure (CASD) has been developed whereby an above-knee socket shape can be created based on anthropometric measurements taken from an amputee. The anthroometric measurements are used to select a subset of three reference shapes from a Reference Shape Library stored in the computer in the form of three-dimensional numerical data. Transformation procedures then scale the reference shapes at each cross-sectional level to match the amputee's cross-sectional areas. Blending of the three shapes is determined by tissue mass weighting factors, to yield a single custom socket configuration, known as the "basic socket shape." Subsequent graphical procedures in the CASD system allows further sculpting of the shape in the form of interactive adjustments of the numerical data to reach the socket shape desired by the prosthetist. The resultant shape data can then be transferred to a computer numerically controlled (CNC) milling machine to carve a model of the socket shape.

Artificial Limbs

Lung volume changes in response to altered breathing gas pressure during upright immersion.

Since elastic and flow-resistive respiratory work are volume dependent, changes in lung volume during immersion affect respiratory effort. This investigation examined changes in lung volume with air delivery pressure modifications during upright immersion. Static pressure-volume relaxation relationships and lung volumes were obtained from ten immersed subjects breathing air at four delivery pressures: mouth pressure, lung centroid pressure (PLC), and 0.98 kPa above and below PLC. The PLC is the static lung pressure which returns the respiratory relaxation volume (VR) to normal and was previously determined to be +1.33 kPa relative to pressure at the sternal notch. Lung volume changes observed when breathing air at mouth pressure were reversed when air was supplied at PLC. The expiratory reserve volume (ERV) and VR were reduced by 58% and 87%, respectively, during uncompensated immersion. These differences indicated an active defence of ERV and implied that additional static respiratory work was required to overcome transrespiratory pressure gradients.

Adult

Exercise breathing pattern during chronic altitude exposure.

Breathing pattern in response to maximal exercise was examined in four subjects during a 7-day acclimatisation to a simulated altitude of 4247 m (barometric pressure, PB = 59.5 kPa). Graded exercise tests to exhaustion were performed during normoxia (day 0), and on days 2 and 7 of hypoxia, respectively. Ventilation was significantly augmented in the hypoxic environment, as were both the mean inspiratory flow (VT/TI) and inspiratory duty cycle (TI/TTOT) components of it. VI/TI was increased due to a significant increase in tidal volume (VT) and a corresponding decrease in inspiratory time duration (TI). Throughout a range of exercise ventilation, TI/TTOT was increased due to an apparently greater decrease in expiratory time duration (TE) with respect to TI. In all cases, the relation between VT and TI displayed a typical range 2 behaviour, with evidence of a range 3 occurring at very high ventilatory rates. There was essentially no difference observed in the VT-TI relation during exercise between the normoxic and hypoxic conditions. No significant changes were observed in the breathing pattern in response to exercise within the exposure period (from day 2 to day 7), although there was a discernible tendency to a higher stage 3 plateau by day 7 of altitude exposure.

Acclimatization

Computer-aided design and manufacture of an above-knee amputee socket.

This paper describes the initial test results obtained from a newly developed computer-aided socket design (CASD) and manufacturing (CASM) process for above-knee amputees. Anthropometric measures taken from an amputee provided input information to a CASD system. Using these measurements, data from a reference shape library stored in the computer were selected and modified to create a unique socket shape reflecting the particular characteristics of the amputation stump. The resultant shape was produced as a 'primitive' test socket by a CASM process. Numerical shape data were then transferred to a CNC milling machine to construct a negative cast, from which the primitive socket was produced by a vacuum-forming procedure. The resultant primitive socket shape was fitted and the amputee was able to load the socket without discomfort. Some shape discrepancies were identified and the shape data were modified interactively by the CASD system to create a final socket shape. The final socket shape was manufactured and worn by the amputee during a 35 min walking trial. Subjective evaluation was that the socket provided comfort and control comparable with that of the conventional socket, and proved to be acceptable to the amputee. This was followed by a 2-month home trial which was also successful. The CASD socket shapes were compared numerically in area, shape and volume with data taken from the original socket worn by the amputee, a new socket made by conventional methods and a topographic model of the amputation stump. The final CASD socket shape compared favourably with that of a socket manufactured by conventional methods.(ABSTRACT TRUNCATED AT 250 WORDS)

Anthropometry

Pulmonary flow-resistive work during hydrostatic loading.

This paper focuses upon flow-resistive pulmonary work during upright immersion, and during changes in the air delivery pressure. Nine male non-smokers (aged 26.2 +/- 3.5 years), with normal lung function history, performed spontaneous respiration while seated in air (control) and during total immersion. During the immersed state subjects were supplied with air at four hydrostatic pressures: mouth pressure (PM; simulating a mouth-held demand regulator), lung centroid pressure (PLC; + 1.33 kPa relative to the sternal notch), and 0.98 kPa (10 cmH2O) above and below the lung centroid pressure. Inspiratory, expiratory and total flow-resistive pulmonary work were computed from the integration of transpulmonary pressure (difference between oesophageal and mouth pressure) with respect to lung volume change. When breathing air delivered at mouth pressure, immersion significantly elevated all total flow-resistive pulmonary work components (P less than 0.05). Each increment in breathing pressure resulted in a progressive reduction in expiratory and total flow-resistive pulmonary work, so that when air was provided at lung centroid pressure and lung centroid pressure +0.98 kPa both components were similar to control values (P greater than 0.05). Inspiratory was always less than expiratory pulmonary work. During immersion inspiratory pulmonary work was significantly reduced when air supply pressure was increased above mouth pressure (P less than 0.05). Subsequent pressure increments failed to produce further changes in inspiratory pulmonary work. The difference in response between the inspiratory and expiratory components of total flow resistive pulmonary work was attributed primarily to the volume-dependence of the expiratory component.

Adult

Effects of CO2 and N2 partial pressures on cognitive and psychomotor performance.

This study examined N2 and CO2 components of narcosis by comparing the effects of three levels of PETCO2 [low = 29 mmHg (SD = 4 mmHg), medium = 47 mmHg (SD = 1 mmHg), high = 57 mmHg (SD = 2 mmHg)] at 1 and 6 atm abs in 12 male volunteers. Cognitive and psychomotor performances were examined using a variety of tasks, including a modified Stroop test, an arithmetic test, number comparison, a figure copying test, and the Purdue pegboard test. Performance on all tasks demonstrated significant (P less than 0.05) decrements at 6 atm abs. High CO2 tensions significantly impaired cognitive and psychomotor performance at 1 atm abs and caused further decrements at 6 atm abs (P less than 0.05). However, no significant N2-CO2 interaction (P greater than 0.05) or global threshold for the onset of CO2 narcosis was indicated by the test scores. The pattern of intratest results were different for N2 and CO2. At high PETCO2, performance deficits were due to a slowing of performance rather than a disruption of the accuracy of processing. Nitrogen narcosis, conversely, produced significant impairment through both decreases in the speed and accuracy of processing on the majority of performance tests. It was concluded that within the PETCO2 ranges studied: a) PETCO2 and PIN2 are additive in their effects on impaired cognitive and psychomotor performance at depth; b) high PETCO2 and PIN2 induce distinctly different strategic responses on the speed accuracy trade-off function of the performance tests; c) decrements in cognitive and psychomotor performance under high PETCO2 do not conform to the predicted narcotic potency of CO2 according to the lipid solubility theory of narcosis.

Adult

Effects of breathing-gas pressure on pulmonary function and work capacity during immersion.

Upright immersion induces respiratory mechanical changes that may impair pulmonary function during hyperbaric exercise. To evaluate this, 10 divers performed an incremental cycling protocol while immersed upright at 1.02 and 6.05 atmospheres absolute (atm abs). Air was supplied at each of two hydrostatic pressures: mouth pressure (Pm: to stimulate a mouth-held demand regulator) and lung centroid pressure (PLC). Subjects perceived air delivery at PLC to be more comfortable at each level of exercise at both absolute pressures (P less than 0.05). At 6.05 atm abs subjects perceived narcosis to be greater for Pm than for PLC air delivery. Hypoventilation was encountered at 6.05 atm abs with PLC air delivery and was further exacerbated when air was delivered at Pm (P less than 0.05). It was concluded that hypoventilation and narcosis are reduced whereas respiratory comfort is increased when air is delivered at PLC. This change is possibly due to improved pulmonary mechanics accompanying PLC air supply pressure.

Adult

Measurement of static and dynamic pulmonary work during pressure breathing.

Various environments alter static and flow-resistive pulmonary mechanics. Of interest to diving physiologists is the negative pressure breathing induced during upright immersions without appropriate modification of air supply pressure. This paper outlines methodologic considerations for determining static and flow-resistive pulmonary work under such exposures. Ten males performed inspiratory pressure-volume relaxation maneuvers and spontaneous breathing in air, and during upright immersion with mouth pressure air supply. The immersed lung centroid pressure (PLC) was +1.19 kPa relative to the hydrostatic pressure at the sternal notch. Immersion elevated inspiratory static work from 0.36 to 1.74 J.liter-1 (P less than 0.05). Pulmonary flow-resistive work was elevated from 0.20 to 0.75 J.liter-1 (P less than 0.05), whereas pulmonary resistance, determined at 0.5 liter.sec-1, increased from 0.18 to 0.44 kPa.liter-1.sec (P less than 0.05). No significant changes in the iso-volume compliance of the lung tissue, chest wall, or total respiratory system were observed (P greater than 0.05). Results indicate that increases in the work of breathing are due to a combination of hydrostatic pressure imbalance, increased pulmonary resistance, and reduced end-expiratory total respiratory compliance.

Adult

Whole-body vibration in underground load-haul-dump vehicles.

Whole-body vibrations (WBV) were measured at the seatpan of load-haul-dump (LHD) vehicles of 3.5-, 5-, 6- and 8-yard capacity at two underground mines. Twenty-two sets of measurements were made involving 11 vehicles, 8 operators and 4 work locations. In each set frequency-weighted rms and peak accelerations were measured in the x, y and z directions, as defined by the ISO (1982), during mucking, driving full, dumping and driving empty. Significant differences in rms accelerations were found between vehicle sizes and between operational tasks (less than or equal to 0.05). The smallest (3.5 yd) vehicle produced the greatest accelerations in the x and z directions. Accelerations in the x and z directions were also greater when driving full and empty than when mucking and dumping. The highest frequency-weighted rms accelerations of 2.0 to 2.8 m/s-2 were recorded in the z (longitudinal) direction. Peak accelerations ranged from 1.2 to greater than or equal to 20 m/s2, resulting in crest-factor ratios in excess of six. The exposure periods for each task were used to calculate mean daily acceleration exposures (m/s2). Of the 22 sets of measurements, 20 exceeded the International Standards Organization (ISO) six-hour daily exposure limit in the z direction of acceleration, and 9 exceeded the six-hour daily exposure limits in all three directions. Acceleration exposure ratios calculated using resultant acceleration vectors as described in ISO (1982), were found to exceed the ISO exposure limit for health or safety in all 22 cases. One-third octave band frequency analysis of the weighted signals indicated that the dominant frequencies were usually 1.6 to 3.15 Hz, except when the vehicles were idling and higher frequencies predominated.

Acceleration

A reference shape library for computer aided socket design in above-knee prostheses.

A Reference Library of socket shapes for an Above-Knee Computer Aided Socket Design (CASD) System has been created. This library forms part of a more general CASD System (Dean & Saunders, 1985; Novicov & Foort, 1982). It consists of a matrix of reference shapes representing above-knee socket characteristics and is based upon skeletal structure, residuum length and tissue mass. A set of 27 biomechanical reference shapes in the form of male plaster casts were produced by a combination of CNC milling and traditional artisan techniques. Each reference shape was digitized to obtain its cylindrical coordinates. Cross-sectional areas and tissue distributions within each shape and between the shapes were analyzed, modified and then stored numerically within the computer for further implementation of the CASD System for the above-knee amputees. The creation and the analysis of the reference shape data is described.

Artificial Limbs

Lung centroid pressure in immersed man.

Upright immersion imposes a pressure imbalance between alveolar and mean external thoracic pressure. Lung centroid pressure (PLC) is defined as the breathing pressure required to remove this imbalance. Static transrespiratory pressure-volume relationships were determined in subjects immersed in upright (n = 17) and prone (n = 13) postures. Compliances measured during immersion (1.87 +/- 0.15 liter.kPa-1 upright, 1.87 +/- 0.17 liter.kPa-1) prone) were compared with compliances, obtained over the same volume range, while upright in air (1.84 +/- 0.17 liter.kPa-1). PLC was determined by the horizontal (pressure) displacement of immersed compliance curves. PLC was calculated to be +1.33 +/- 0.11 kPa (+13.6 cmH2O) relative to the sternal notch when upright and -0.69 +/- 0.12 kPa (-7.0 cmH2O) relative to the sternal plane when prone (mean +/- SEM). Upright PLC did not support the widely used value of +19 cmH2O (Jarrett AS. J Appl Physiol 1965;20:1261-1266). Analysis shows that when data from earlier investigations were adjusted for differences in reference pressure, the collective PLC supports the present results.

Adult

Chronic asthma and improvement with relaxation induced by hypnotherapy.

Sixteen chronic asthmatic patients inadequately controlled by drugs had, after one year of hypnotherapy, a fall in admissions from 44 in the year before starting therapy to 13 in the year after. Duration of stay was reduced for 13 patients by 249 days; prednisolone was withdrawn in 6, reduced in 8 and increased in none. Side effects of drugs were reduced. Although 62% reported improvement on a visual analogue scale, observations of air flow gave variable results.

Adolescent

Thermal increment provided by inhalation rewarming from hypothermia.

To quantify the core temperature gain derived from inhalation rewarming, 10 subjects were immersed in seawater (mean temperature 12 degrees C) until a 2 degree C drop in rectal temperature occurred, and were then rewarmed by breathing hot saturated air at 45 degrees C for 30 min. Each subject was rewarmed once breathing air and once rebreathing a controlled fraction of expired air adjusted to produce a hyperventilation of 50 l/min. After 30 min of rewarming mean rectal temperature had increased 0.39 degrees C in subjects breathing air compared with 0.77 degrees C in those hyperventilating (P less than 0.01). Corresponding gains in tympanic temperatures were 1.1 and 1.5 degrees C, respectively. Calculations indicate that the additional heat input with hyperventilation yielded a core (rectal) temperature gain of 5.1 X 10(-4) degrees C/l. It is concluded that each additional 10 l/min of ventilation of hot saturated air will increase the rate of core rewarming from hypothermia by approximately 0.3 degrees C/h.

Adult

Breathing pattern and ventilatory response to carbon dioxide in divers.

The breathing pattern and ventilatory response to carbon dioxide of 10 experienced divers was compared with that of 10 nondivers of similar age and build. Breathing pattern was described by the equation VE = M (VT - K) and the response to carbon dioxide by VE = S(PCO2 - B). The divers exhibited a value form 27% lower than the nondivers; S was 33% lower. The difference was significant (P less than 0.05) in both cases. B was significantly higher (P less than 0.05) in the divers than nondivers. These differences are not attributable to age, build, or vital capacity. S was well correlated with M when all subjects were considered a single group. Within the diving group no correlation of S and M with diving experience was found.

Adaptation, Physiological