PubMed Health⌕ Search

Biomedical subjects

J B Seward

Publications and source records attributed to J B Seward.

At least 37 records · Page 2Linked to original sources

Initial experience with a steerable, phased vector array ultrasound catheter in the GI tract.

BACKGROUND: EUS requires a significant capital outlay. The ability to perform high-resolution phased array scanning and Doppler interrogation by using a catheter that interfaces with a standard US console could increase the accessibility of EUS. Recently, an electronic phased-array US catheter was developed for intracardiac use. To date, this technology has not been applied to the GI tract. The aim of this study is to determine the feasibility and imaging characteristics of a new phased array scanning US catheter in the GI tract. METHODS: Swine were placed under general anesthesia. This study used a 100 cm, 10F, torquable catheter with 4-way tip deflection to greater than 90 degrees. The catheter tip houses a phased vector array transducer with variable frequency (5.5-10 MHz) and variable focal distance. It has pulsed/color and power Doppler capability. The probe was passed through a therapeutic flexible sigmoidoscope into the upper GI tract. Acoustic coupling was achieved via a condom filled with water or by gastric water infusion. Needle visualization experiments were performed with a second endoscope (also passed per oral) with a standard EUS-guided fine needle aspiration needle. RESULTS: Acoustic coupling was easily achieved. Resolution of the GI wall into characteristic layers (esophagus 5, stomach 7) was demonstrated. At 5.5 MHz, tissue resolution and Doppler imaging were excellent to greater than 10 cm from the transducer. A 22-gauge EUS-guided fine needle aspiration needle was easily visualized at depth greater than 4 cm. Flow in gastric, hepatic, and pancreatic parenchymal vessels approximately 1 mm diameter was visualized by using power and color Doppler. CONCLUSIONS: This 10F array US catheter is capable of high-resolution two-dimensional imaging of the gut wall as well as high-quality Doppler imaging. The Doppler capabilities of this equipment may have new GI applications.

Animals↗

Real-time strain rate echocardiographic imaging: temporal and spatial analysis of postsystolic compression in acutely ischemic myocardium.

Postsystolic compression (PSC) is a sensitive indicator of regional left ventricular ischemic diastolic dysfunction. Quantitative assessment of compression patterns by strain rate imaging could determine the presence and spatial extent of PSC for the detection and analysis of acute ischemic diastolic dysfunction. With the use of a segmental left ventricular model, we evaluated time to compression/expansion crossover (T-CEC) in standard apical views. Data at baseline and after acute left anterior descending coronary artery occlusion were collected from 18 open-chest pigs. We found significant mean prolongation of T-CEC, ranging from 43.9 +/- 48.6 ms to 110.8 +/- 73.8 ms, in all apical segments and in 2 midventricular (anterior and anteroseptal) segments. Analysis of variance demonstrated that the prolonged T-CEC is spatially consistent with perfusion defect. The temporal and spatial analysis of T-CEC with the use of strain rate imaging is a new noninvasive technique for identification and topographic quantitation of ischemic diastolic dysfunction expressed by PSC.

Animals↗

Radiofrequency spectral analysis of attenuated ultrasound signals in experiments with echo contrast microbubbles.

Conventional gray-scale myocardial contrast echocardiography cannot distinguish perfused but attenuated from nonperfused myocardium because both may appear similar at low image intensity. We hypothesized that with radiofrequency spectral analysis of attenuated ultrasound signals, the harmonic-to-fundamental frequency ratio of the peak power spectrum (HFR(P)) could determine the presence of contrast microbubbles. We measured frequency responses of Optison microbubbles at defined degrees of ultrasound signal attenuation with different formulations of silicone (55D, 80A, and 3M); gray-scale intensities of Optison plus water compared with degassed water were analyzed at different attenuation settings (-25, -32, and -44 dB, respectively). HFR(P) values of Optison plus water were significantly higher than reference values of degassed water at each attenuation setting (55D, -14 +/- 2 dB versus -30 +/- 2 dB, P <.001; 80A, -19 +/- 2 dB versus -30 +/- 3 dB, P <.01; 3M, -22 +/- 2 dB versus -30 +/- 3 dB, P <.05), even though conventional videodensitometric analysis could not distinguish them. HFR(P) analysis objectively detects microbubbles in clinically relevant conditions of attenuation.

Contrast Media↗

Color M-mode and pulsed wave tissue Doppler echocardiography: powerful predictors of cardiac events after first myocardial infarction.

To assess the association between color M-mode flow propagation velocity and the early diastolic mitral annular velocity (E(m)) obtained with tissue Doppler echocardiography and to assess the prognostic implications of the indexes, echocardiography was performed on days 1 and 5, and 1 and 3 months after a first myocardial infarction in 67 consecutive patients. Flow propagation velocity correlated well with E(m) (r = 0.72, P <.0001). The ratio of peak E-wave velocity (E) to flow propagation velocity also correlated well with E/E(m) (r = 0.87, P <.0001). The positive predictive value of E/FPV > or =1.5 to identify patients with Killip class > or =II was 90%, and the negative predictive value 92%. The corresponding values for E/E(m) > or =10 were 70% and 90%. Cox proportional hazards analysis identified E/flow propagation velocity > or =1.5 (relative risk, 12.4 [95% confidence interval, 4.1-37.3]), E/E(m) > or =10 (relative risk, 11.5 [95% confidence interval, 3.8-34.7]), and Killip class > or =II (relative risk, 7.8 [95% confidence interval, 1.6-40.4]) to be predictors of the composite end point of cardiac death and readmission because of heart failure. Thus flow propagation velocity and E(m) are closely related after myocardial infarction and appear to have similar prognostic information.

Aged↗

Analysis of systolic and diastolic time intervals during dobutamine-atropine stress echocardiography: diagnostic potential of the Doppler myocardial performance index.

Systolic and especially diastolic Doppler time intervals may be early markers of myocardial ischemia inducible by dobutamine-atropine stress echocardiography (DASE). We postulated that the Doppler myocardial performance index (MPI) may help differentiate ischemic from nonischemic responses. Hemodynamic and Doppler echocardiography variables were measured prospectively at every stress level of DASE in 32 patients (mean age 67 +/- 13 years). Adequate recordings were obtained in 27 patients; 13 had an ischemic response (group I) and 14 a nonischemic response (group II). Heart rate differed between groups at baseline. At equivalent peak stress, left ventricular wall motion score index was significantly greater and ejection fraction lower in group I patients. Of the Doppler variables, only the MPI consistently differed between groups, irrespective of the number of stress levels compared. The Doppler MPI may be a useful adjunct to wall motion analysis in the detection of myocardial ischemia during DASE.

Adrenergic beta-Agonists↗

Association of atrial fibrillation and aortic atherosclerosis: a population-based study.

OBJECTIVE: To examine the association between atrial fibrillation (AF) and aortic atherosclerosis in the general population. SUBJECTS AND METHODS: Transesophageal echocardiography was performed in 581 subjects, a random sample of the adult Olmsted County, Minnesota, population (45 years of age or older) participating in the Stroke Prevention: Assessment of Risk in a Community (SPARC) study. The frequency of aortic atherosclerosis was determined in 42 subjects with AF and compared with that in 539 subjects without AF (non-AF group). RESULTS: Subjects with AF were significantly older than non-AF subjects (mean +/- SD age, 82+/-10 vs 66+/-13 years, respectively; P<.001) and more commonly had hypertension (28 [66.7%] vs 288 [53.4%], respectively; P=.10). The 2 groups were similar in sex and frequency of diabetes mellitus, hyperlipidemia, or smoking history (P>.10). The odds of aortic atherosclerosis (of any degree) were 2.87 times greater (95% confidence interval [CI], 1.41-5.83; P=.004) and the odds of complex atherosclerosis (protruding atheroma >4 mm thick, mobile debris, or plaque ulceration) were 2.71 times greater (CI, 1.13-6.53; P=.03) in the AF group than in the non-AF group. Age was a significant predictor of aortic atherosclerosis (P<.001). After adjusting for age, the odds of atherosclerosis and complex atherosclerosis were not significantly different between the 2 groups (P=.13 and P=.75, respectively). CONCLUSIONS: In the general population, AF is associated with aortic atherosclerosis, including complex atherosclerosis. This association is related to age since both AF and aortic atherosclerosis are more frequent in the elderly population.

Adult↗

Safety of electrical cardioversion in patients with previous embolic events.

OBJECTIVE: To assess thromboembolic complications in cardioversions in patients with atrial fibrillation or flutter and a previous embolic event. PATIENTS AND METHODS: The study population consisted of 104 patients with previous embolic events who underwent 128 electrical cardioversions for termination of atrial fibrillation or flutter. The primary outcome measure was successful cardioversion. RESULTS: Anticoagulants were administered in 118 procedures (92%). Cardioversion was successful in 108 (84%) of the 128 procedures. Only 1 embolic event occurred within 30 days after cardioversion (incidence, 0.9% of successful procedures; 95 % confidence interval, 0.02%-5.3%). The single embolic event was a transient neurologic deficit occurring 22 days after cardioversion in a patient with previous atrial fibrillation. This patient had a sub-therapeutic level of anticoagulation. Transesophageal echocardiography revealed no spontaneous echo contrast or thrombi before the procedure. No thromboembolism was noted in patients who had therapeutic anticoagulation or in those with failed cardioversion. CONCLUSION: Patients with previous embolism are not at additional risk of thromboembolic complications after cardioversion if anticoagulation is adequate.

Aged↗

Left atrial volume: important risk marker of incident atrial fibrillation in 1655 older men and women.

OBJECTIVE: To evaluate the contribution of left atrial (LA) volume in predicting atrial fibrillation (AF). PATIENTS AND METHODS: In this retrospective cohort study, a random sample of 2200 adults was identified from all Olmsted County, Minnesota, residents who had undergone transthoracic echocardiographic assessment between 1990 and 1998 and were 65 years of age or older at the time of examination, were in sinus rhythm, and had no history of AF or other atrial arrhythmias, stroke, pacemaker, congenital heart disease, or valve surgery. The LA volume was measured off-line by using a biplane area-length method. Clinical characteristics and the outcome event of incident AF were determined by retrospective review of medical records. Echocardiographic data were retrieved from the laboratory database. From this cohort, 1655 patients in whom LA size data were available were followed from baseline echocardiogram until development of AF or death. The clinical and echocardiographic associations of AF, especially with respect to the role of LA volume in predicting AF, were determined. RESULTS: A total of 666 men and 989 women, mean +/- SD age of 75.2 +/- 7.3 years (range, 65-105 years), were followed for a mean +/- SD of 3.97 +/- 2.75 years (range, < 1.00-10.78 years); 189 (11.4%) developed AF. Cox model 5-year cumulative risks of AF by quartiles of LA volume were 3%, 12%, 15%, and 26%, respectively. With Cox proportional hazards multivariate models, logarithmic LA volume was an independent predictor of AF, incremental to clinical risk factors. After adjusting for age, sex, valvular heart disease, and hypertension, a 30% larger LA volume was associated with a 43% greater risk of AF, incremental to history of congestive heart failure (hazard ratio [HR], 1.887; 95% confidence interval [CI], 1.230-2.895; P = .004), myocardial infarction (HR, 1.751; 95% CI, 1.189-2.577; P = .004), and diabetes (HR, 1.734; 95% CI, 1.066-2.819; P = .03). Left atrial volume remained incremental to combined clinical risk factors and M-mode LA dimension for prediction of AF (P < .001). CONCLUSION: This study showed that a larger LA volume was associated with a higher risk of AF in older patients. The predictive value of LA volume was incremental to that of clinical risk profile and conventional M-mode LA dimension.

Aged↗

Shape reconstruction of the left ventricle: accuracy of limited-plane three-dimensional echocardiography.

OBJECTIVE: To assess the accuracy of left ventricular cavity shape reproduction from 8 spatially related, apical two-dimensional ultrasonographic images. METHODS: We scanned 6 dog heart specimens. Left ventricular cavity casts were reconstructed from 48-tomogram (high-density), 8-tomogram (octaplane), and 2-tomogram (low-density biplane) apical data sets. The 48-plane left ventricular cast served as the reference. Spatial shape resolution of 3 mm in radial distance from the rotational axis to the interpolated endocardium was used as the criterion of shape accuracy. RESULTS: The adjusted limits of agreement for the octaplane and biplane left ventricular casts were +/-2.31 and +/-6.84 mm, respectively. CONCLUSIONS: The three-dimensional left ventricular cavity shape can be accurately reproduced by using a low-data density apical octaplane echocardiographic examination.

Animals↗

Effects of sildenafil citrate (Viagra) combined with nitrate on the heart.

BACKGROUND: Sildenafil citrate (Viagra) is indicated for the treatment of erectile dysfunction. Large and sudden decreases in systemic blood pressure were reported in a substantial number of patients taking sildenafil citrate combined with nitroglycerin. We studied the effect of sildenafil citrate on the relationship between changes in systemic blood pressure and coronary blood flow. METHODS AND RESULTS: Healthy male beagles were used to assess systemic blood pressure, pulmonary arterial pressure, and flow in the left circumflex artery (in which a critical stenosis was established) and left anterior descending coronary artery. After measurement of the hemodynamic variables, 2 mg/kg sildenafil citrate was administered via a nasogastric tube. Hemodynamic changes were monitored for 1 hour. Subsequently, the acute effect of nitrate combined with sildenafil citrate was studied by the bolus injection of 0.2 mg isosorbide dinitrate before and after sildenafil citrate. Systemic blood and pulmonary arterial pressures and circumflex flow did not change during this study; however, left anterior descending coronary arterial flow increased from 16.0+/-5.8 to 24.6+/-8.7 mL/min 1 hour after administration of sildenafil citrate. The prolongation of systemic blood pressure decrease and the circumflex flow decrement induced by isosorbide dinitrate after sildenafil citrate were significantly larger and longer than those before sildenafil citrate. CONCLUSIONS: Sildenafil citrate had the effect of vasodilation in a normal coronary artery; however, a combined effect with nitrate resulted in large and protracted decreases in systemic blood pressure and coronary blood flow in vessels with critical stenosis.

Administration, Oral↗

Transthoracic Doppler echocardiographic comparison of left internal mammary grafts to left anterior descending coronary artery with ungrafted right internal mammary arteries in patients with and without myocardial ischemia by dobutamine stress echocardiography.

To characterize Doppler flow patterns of the grafted left internal mammary artery (LIMA) in patients with and without dobutamine stress induced wall motion abnormalities in the graft distribution, we studied 29 patients who underwent coronary artery bypass surgery using LIMA grafts to the left anterior descending coronary artery (LAD). The ungrafted right internal mammary artery (RIMA) was used as a control. RIMA Doppler flow pattern was predominantly systolic in all patients. In patients without ischemia in the LAD distribution, LIMA flow was predominantly diastolic. In patients with ischemia, LIMA flow was predominantly systolic. In the grafted LIMA, a ratio of diastolic to systolic time-velocity integral of > 1.5 best showed absence of ischemia in the graft distribution. In summary, characterization of the Doppler flow pattern in the internal mammary arteries is feasible. In the grafted LIMA, ratios of diastolic to systolic flow are less in patients with an ischemic response in the subtended vascular bed than in those without ischemia.

Aged↗

A rapid stress-testing protocol for the detection of coronary artery disease: comparison of two-stage transesophageal atrial pacing stress echocardiography with dobutamine stress echocardiography.

OBJECTIVES: We compared a new two-stage transesophageal atrial pacing stress echocardiography (TAPSE) protocol with a standard dobutamine stress echocardiography (DSE) protocol. BACKGROUND: Transesophageal atrial pacing stress echocardiography has been proposed as an efficient alternative to DSE. METHODS: Two-stage TAPSE (85% and 100% of age-predicted maximum heart rate) and DSE (5 to 40 microg/kg/min at 3-min stages with or without atropine) were both performed, in random sequence, in each patient of a study group of 36 patients. Regional wall-motion analysis, patient acceptance (1 = low, 5 = high), hemodynamics and duration for performing and interpreting tests were compared. RESULTS: Transesophageal atrial pacing stress echocardiography was successful in 35 of the 36 patients (feasibility 97%). More TAPSE than DSE studies were called "ischemic" (37% vs. 14%; p = 0.005). Peak heart rate was higher with TAPSE (144 +/- 18 vs. 129 +/- 15 beats/min, p = 0.0001). Peak cardiac index (4.6 +/- 2.1 vs. 5.1 +/- 1.9 liters/min/m2, p = 0.14), patient acceptance score (4.2 +/- 0.7 vs. 3.8 +/- 1.3, p = 0.17) and study duration (14.2 +/- 9.3 vs. 13.3 +/- 3.3 min, p = 0.59) were similar. Recovery time (7.1 +/- 7.6 vs. 16.2 +/- 15.9 min, p = 0.0003) and interpretation time (9.1 +/- 2.8 vs. 13.5 +/- 4.4 min, p = 0.0001) were shorter for TAPSE than for DSE. CONCLUSIONS: Two-stage TAPSE permits rapid evaluation of cardiac patients. Peak cardiac index and patient acceptance scores were similar for TAPSE and DSE. Ischemia was detected more often with TAPSE; this result was attributed to the higher peak heart rate obtained with this protocol.

Aged↗

Independent association of high blood pressure and aortic atherosclerosis: A population-based study.

BACKGROUND: Atherosclerosis of the thoracic aorta is associated with stroke. The association between hypertension, a major risk factor for stroke, and aortic atherosclerosis has not been determined in the general population. METHODS AND RESULTS: Transesophageal echocardiography was performed in 581 subjects, a random sample of the Olmsted County (Minnesota) population aged >/=45 years participating in the Stroke Prevention: Assessment of Risk in a Community (SPARC) study. Blood pressure was assessed by multiple office measurements and 24-hour ambulatory blood pressure monitoring. The association between blood pressure variables and aortic atherosclerosis was evaluated by multiple logistic regression, adjusting for other associated variables. Among subjects with atherosclerosis, blood pressure variables associated with complex aortic atherosclerosis (protruding plaques >/=4 mm thick, mobile debris, or ulceration) were determined. Age and smoking history were independently associated with aortic atherosclerosis of any degree (P:</=0.001) and with complex atherosclerosis (P:=0.002), whereas sex, diabetes mellitus, and body mass index were not. Multiple systolic and pulse pressure variables (office and ambulatory), but none of the diastolic blood pressure variables, were associated with atherosclerosis and complex atherosclerosis, adjusting for age and smoking. Among subjects with atherosclerosis, the odds of complex atherosclerosis increased as ambulatory out-of-bed systolic blood pressure increased (odds ratio 1.43 per 10 mm Hg increase, 95% CI 1. 10 to 1.87) and with hypertension treatment, adjusting for age and smoking history. CONCLUSIONS: High blood pressure is independently associated with aortic atherosclerosis. Among subjects with atherosclerosis, high blood pressure is associated with complex atherosclerosis.

Age Distribution↗

Left atrial appendage flow velocities in subjects with normal left ventricular function.

The objectives of this study were to establish reference values and define the determinants of left atrial appendage (LAA) flow velocities in the general population. LAA flow velocities (contraction and filling velocities) were assessed by transesophageal echocardiography in 310 subjects aged > or = 45 years, sampled from the population-based Stroke Prevention: Assessment of Risk in a Community study. All subjects were in sinus rhythm, with preserved left ventricular systolic function (ejection fraction > or = 50%), and without valvular disease. Values of LAA contraction and filling velocities were established for various age groups in the population. Age was negatively associated with LAA contraction and filling velocities, which decreased by 4.1 cm/s (p < 0.001) and 2.0 cm/s (p < 0.01) for every 10 years of age, respectively. Contraction velocities were 5 cm/s higher in men than in women (p < 0.05). After adjusting for age and sex, heart rate was independently associated with LAA contraction velocities (p < 0.001; nonlinear association). Body surface area, left atrial size, left ventricular mass index, and a history of previous cardiac disease or hypertension showed no significant association with LAA flow velocities (p > 0.05). Furthermore, detailed analysis of 24-hour ambulatory blood pressure data (available in 253 subjects) showed no association between various blood pressure parameters (systolic and diastolic blood pressure, out-of-bed and in-bed measurements) and LAA flow velocities (all p > 0.05). In summary, the present study establishes the reference values for LAA flow velocities in a large sample of the general population. LAA flow velocities progressively decline with age in subjects with preserved left ventricular systolic function.

Age Factors↗

Determinants of the degree of functional mitral regurgitation in patients with systolic left ventricular dysfunction: A quantitative clinical study.

BACKGROUND: Functional mitral regurgitation (FMR) occurs with a structurally normal valve as a complication of systolic left ventricular dysfunction (LVD). Determinants of degree of FMR are poorly defined; thus, mechanistic therapeutic approaches to FMR are hindered. METHODS AND RESULTS: In a prospective study of 21 control subjects and 128 patients with LVD (defined as ejection fraction <50%, mean 31+/-9%) in sinus rhythm, we quantified simultaneously by echocardiography the effective regurgitant orifice (ERO) of FMR by using 2 methods: mitral deformation (valve and annulus) and left ventricular (LV) global (volumes, stress, function, and sphericity) and local (papillary muscle displacements and regional wall motion index) remodeling. A wide range of ERO (15+/-14 mm(2), 0 to 87 mm(2)) was observed, unrelated to ejection fraction (P:=0.32). The major determinant of ERO was mitral deformation, ie, systolic valvular tenting and annular contraction in univariate (r=0.74 and r=-0.61, respectively; both P:<0.0001) and multivariate (both P:<0. 0001) analyses, independent of global LV remodeling. Systolic valvular tenting was strongly determined by local LV alterations, particularly apical (r=0.75) and posterior (r=0.70) displacement of papillary muscle, with confirmation in multivariate analysis (both P:<0.0001), independent of LV volumes, function, and sphericity. CONCLUSIONS: The presence and degree of FMR complicating LVD are unrelated to the severity of LVD. Local LV remodeling (apical and posterior displacement of papillary muscles) leads to excess valvular tenting independent of global LV remodeling. In turn, excess tenting and loss of systolic annular contraction are associated with larger EROs. These determinants of FMR warrant consideration for specific approaches to the treatment of FMR complicating LVD.

Aged↗

Usefulness of the myocardial performance index for assessing right ventricular function in congenital heart disease.

Quantitative assessment of ventricular function in patients with congenital heart disease is often challenging due to distorted ventricular geometry. A myocardial performance index (MPI) has been reported in adults and children that is a Doppler-derived nongeometric measure of ventricular function. The MPI measures the ratio of isovolumic time intervals (isovolumic contraction time and isovolumic relaxation time) to ventricular ejection time. The effects of altered ventricular preload or afterload on the MPI have yet to be determined. This study assesses the impact of altered preload or afterload on right ventricular (RV) function and the RV MPI in the clinical setting of congenital heart disease. Patient groups were compared with normal pediatric and adult populations before and after repair of their congenital heart lesion. Patients with large atrial septal defects (ASDs) represented the clinical setting of increased ventricular preload, whereas patients with isolated pulmonary valve stenosis represented increased RV afterload. Patients with congenitally corrected transposition of the great arteries (CC-TGA) with severe left atrioventricular valve regurgitation represented a combined increase in RV preload and afterload. The RV MPI in 152 normal children (ages 3 to 18 years) and 37 adults (ages 18 to 51 years) was 0.32 +/- 0.03 and 0.28 +/- 0.04, respectively. In pediatric patients (n = 45) and adult patients (n = 40) with ASD, the RV MPI was 0.35 +/- 0.09 (p = NS) and 0.38 +/- 0.04 (p < 0.01 compared with normal adults), respectively. Patients with pulmonary stenosis (n = 21, ages 1 day to 19 years) had a RV MPI of 0.32 +/- 0.06 (p = NS). CC-TGA patients had a RV MPI of 0.72 +/- 0.17 (p < 0.001). No significant change in the RV MPI was seen in any postoperative patient group despite relief of RV volume or pressure overload. Thus, the MPI is a quantitative measure of RV performance that is appears to be relatively independent of changes in preload or afterload in the clinical setting.

Adolescent↗

Evaluation of coronary flow reserve in hypertensive patients by dipyridamole transesophageal doppler echocardiography.

This study evaluates the coronary flow reserve (CFR) in hypertensive patients with and without left ventricular (LV) hypertrophy. CFR was assessed by transesophageal Doppler echocardiography in 15 normal subjects (group I), 21 hypertensive patients without LV hypertrophy (group II), and 27 hypertensive patients with LV hypertrophy (group III). All hypertensive patients were complaining of typical anginal pain and had normal coronary angiograms. The sample volume was placed at the bifurcation of the left main and left anterior descending coronary arteries. Coronary blood flow velocities were evaluated at rest, 2 minutes after dipyridamole infusion, and 2 minutes after intravenous aminophylline. The ratios of dipyridamole to rest peak diastolic and systolic velocities were considered as indexes of CFR. Peak diastolic velocity ratio was significantly lower in group III than in groups I and II (1.6 +/- 0.2, 2.7 +/- 0.4, and 2.1 +/- 0.2, respectively; p <0.05), and it was significantly lower in group II than I (p <0.05). The peak systolic velocity ratio was significantly lower in group III than in groups I and II (1.7 +/- 0.3, 2.8 +/- 0.3, and 2.1 +/- 0.2, respectively; p <0.05), and it was significantly lower in group II than I (p <0.05). The peak diastolic velocity ratio was inversely related to systolic blood pressure, diastolic blood pressure, and LV mass index (r = -0.48, -0. 51, and -0.37 respectively) in hypertensive patients. It is concluded that CFR is significantly impaired in hypertensive patients, especially those with LV hypertrophy, compared with healthy subjects. The degree of impairment of CFR is related to LV mass index.

Angina Pectoris↗

Assessment of severity of aortic regurgitation using the width of the vena contracta: A clinical color Doppler imaging study.

BACKGROUND: The width of the vena contracta (VC-W), the smallest area of regurgitant flow, reflects the degree of valvular regurgitation and is measurable by color Doppler imaging, but this method has not been validated in aortic regurgitation (AR). METHODS AND RESULTS: We prospectively examined 79 patients with isolated AR and 80 patients without regurgitation. The VC-W was measured from the long-axis parasternal view and compared with 2 simultaneous reference methods (quantitative Doppler and 2D echocardiography). In patients without regurgitation, the agreement between methods was excellent. In patients with AR, good correlations (all P<0.0001) were obtained between VC-W and effective regurgitant orifice (ERO) area and regurgitant volume recorded by quantitative Doppler (r=0.89 and 0.90, respectively) and 2D echocardiographic (r=0.90 and 0.89, respectively) methods. These correlations were similar with eccentric or central jets (all P>0.60). The other methods used showed good correlations of VC-W with aortographic grading of AR (n=8, r=0.82, P=0.01), with the proximal flow convergence method (n=53, r=0.85, P<0.0001), and with left ventricular end-diastolic volume (r=0.81, P<0.0001). Sensitivity and specificity of VC-W >/=6 mm for diagnosing severe AR (ERO >/=30 mm(2)) were 95% and 90%, respectively. CONCLUSIONS: For assessment of the degree of AR, VC-W shows good correlations with simultaneous quantitative measures (regardless of jet direction), shows good correlations with other methods of assessment of AR, and provides a high diagnostic value for severe AR. VC-W is a simple, reliable method that can be used clinically as part of comprehensive Doppler echocardiographic assessment of AR.

Aortic Valve Insufficiency↗