Ex vivo phase 1 evaluation of the DeBakey/NASA axial flow ventricular assist device.

A small ventricular assist device intended for long-term implantation has been developed by a cooperative effort between the Baylor College of Medicine and the NASA/Johnson Space Center. To date, in vitro tests have been performed to address hemolysis and pump performance issues. In this Phase 1 study, we assessed the durability and atraumatic features aiming for 2 day implantation. Eight pumps were implanted in 2 calves as paracorporeal left ventricular assist devices. The pump running times ranged from 18 to 203 h (78.1 +/- 23.7; mean +/- SEM). All the pump implantations were terminated because of thrombus formation. Plasma-free hemoglobin levels were below 13.7 mg/dl, except for 1 case complicated by inflow cannula obstruction. The pump speed was maintained between 10,100 and 11,400 rpm. Pump outputs were from 3.6 to 5.2 L/min. The electrical power required by the system ranged between 9 and 12 W. Clinically there was no detectable organ dysfunction noted, and postmortem evaluation demonstrated no pump related adverse effects in either calf except for small kidney infarctions. Thrombus deposition was observed mainly at the hub portions and the flow straightener.

Alanine Transaminase↗

Development of an axial flow ventricular assist device: in vitro and in vivo evaluation.

A collaborative effort between Baylor College of Medicine and NASA/Johnson Space Center is underway to develop an axial flow ventricular assist device (VAD). We evaluated inducer/impeller component designs in a series of in vitro hemolysis tests. As a result of computational fluid dynamic analysis, a flow inducer was added to the front of the pump impeller. According to the surface pressure distribution, the flow inducer blades were connected to the impeller long blades. This modification eliminated high negative pressure areas at the leading edge of the impeller. Comparative studies were performed between inducer blade sections that flowed smoothly into the impeller blades (continuous blades) and those that formed discrete separate pumping sections (discontinuous blades). The inducer/impeller with continuous blades showed significantly (p < 0.003) lower hemolysis with a normalized index of hemolysis (NIH) of 0.018 +/- 0.007 g/100 L (n = 3), compared with the discontinuous model, which demonstrated an NIH of 0.050 +/- 0.007 g/100 L (n = 3). The continuous blade model was evaluated in vivo for 2 days with no problems. One of the pumps evaluated ran for 5 days in vivo although thrombus formation was recognized on the flow straightener and the inducer/impeller. As a result of this study, the pump material was changed from polyether polyurethane to polycarbonate. The fabrication method was also changed to a computer numerically controlled (CNC) milling process with a final vapor polish. These changes resulted in an NIH of 0.0029 +/- 0.0009 g/100 L (n = 4), which is a significant (p < .0001) value 6 times less than that of the previous model.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Axial flow ventricular assist device: system performance considerations.

A cooperative effort between Baylor College of Medicine and NASA/Johnson Space Center is under way to develop an implantable left ventricular assist device for either pulmonary or systemic circulatory support for more than 3 months' duration. Using methodical evaluation and testing, an implantable axial pump has been systematically improved. These improvements include the addition of an inducer as a pumping element in front of the impeller and the construction of an efficient brushless direct current motor. To date, less than 10 W of power is required to generate 5 L/min flow against 100 mm Hg. An index of hemolysis of 0.021 g/100 L has been achieved. Two-day in vivo feasibility studies in calves are under way to evaluate the antithrombogenic nature of the pump. Further improvements in system efficiency, hemolytic performance, and the antithrombogenic nature of the pump are expected with the use of empirical studies, computer flow modeling, and in vivo testing in calves.

Animals↗