Finite element model determination of correction factors used for measurement of aortic diameter via conductance.

Traditional methods for estimating the slope alpha and offset volume Vp for determining real-time chamber volume by the conductance catheter technique are not suited to measurements made in the aorta due to the relatively low resistivity of the aortic wall. We developed three distinct three-dimensional finite element models of the conductance catheter and surrounding tissues in order to predict alpha and Vp and to examine the nature of the electric field near the aortic wall. A heterogeneous isotropic model of the catheter, aorta and surrounding tissues accurately predicted the values of alpha and Vp. A homogeneous anisotropic model was developed to examine the effects of anisotropy of blood and the layers of the aortic wall on measured values of resistance, alpha and Vp. This model demonstrated that anisotropy of blood and aortic wall tissue can increase the values of both alpha and Vp. Finally, a three-dimensional homogeneous isotropic rectangular model allowed examination of the effects of catheter position. This model showed small effects of catheter position on measured resistance (9.7% increase) and larger effects on alpha (21.2% decrease) and Vp (41.9% increase). We conclude the following: the FEA models may lead to accurate estimate values of alpha and Vp in vivo. The unique anisotropic conductive properties of the layers of the aortic wall contribute to the high observed values of alpha and Vp in the aorta. Finally, catheter position has a proportionately greater effect on alpha and Vp than on measured resistance. The results of this study should assist in the determination of aortic mechanical properties using conductance catheter measurements of vessel dimension.

Animals↗

In vivo measurement of real-time aortic segmental volume using the conductance catheter.

The goal of this investigation was to determine if the conductance catheter technique for chamber volume measurement could be applied in vivo to determine real-time phasic aortic segmental volume. A four-electrode conductance catheter was used to measure time-varying resistance of the descending thoracic aorta in open-chest, anesthetized dogs. Resistance was converted to segmental volume and the slope correction factor (alpha) and parallel conductance volume (Vp) were determined. The results showed excellent linear correlation between conductance and sonomicrometric segmental volume. The correction factors alpha and Vp were found to be empirically related to average vessel diameter. The relatively high values for the slope correction factor (alpha=4.59+/-0.17 SEM) were found to be primarily related to low-resistivity shunt paths probably originating in the periadventitial aortic wall and to a lesser extent to changes in flow-induced increases in blood resistivity, hematocrit, catheter position, and other adjacent tissue resistivity. The results demonstrate that correction factors empirically derived from measurements of mean aortic diameter could be used to determine absolute real-time phasic segmental volume, cross-sectional area, or diameter. The conductance technique may possess the same potential for determining aortic mechanical properties which has already been demonstrated for determining ventricular mechanical properties.

Animals↗

A probe for measuring current density during magnetic stimulation.

Time-varying magnetic fields induce currents in conductive media, and when the induced current is large enough in excitable tissue, stimulation occurs. This phenomenon has been applied to the human brain and peripheral nerves for diagnostic evaluation of the neural system. One important aspect that is presently unknown is the current level necessary in tissue for stimulation induced by magnetic fields. This study presents a method of measuring the induced current density from pulsed magnetic fields in vitro and in vivo. The current-density probe was inserted into three concentrations of saline and into the brains of ten anesthetized cats. Two stimulation systems with coils 9 cm and 5 cm in diameter were used. The two systems provided sinusoidal and pulsatile coil currents. Measurements made in saline were compared with those calculated theoretically for a semi-infinite medium. The measured values were within 5% of the calculated values. Measurements made in the cat brain showed a 67% decrease compared with the theoretic model. This variance is attributed to the finite bounds of the skull. The results indicate that direct measurement of current density is possible. Subsequent measurements will aid in the design of improved magnetic stimulation systems.

Animals↗