PubMed Health⌕ Search

Biomedical subjects

J Bezemer

Publications and source records attributed to J Bezemer.

3 recordsLinked to original sources

Incorporation of different antibiotics into carbonated hydroxyapatite coatings on titanium implants, release and antibiotic efficacy.

Carbonated hydroxyapatite (CHA) coatings were applied onto titanium implants by using a biomimetic precipitation method. Different antibiotics were incorporated into the CHA coatings and their release and efficacy against bacteria growth were studied in vitro. The following antibiotics were used within this study: cephalothin, carbenicillin, amoxicillin, cefamandol, tobramycin, gentamicin and vancomycin. Increased concentrations of antibiotics in the coating solution led to a higher quantity of antibiotic incorporated into the CHA coating. Some antibiotics were better incorporated than others depending on their chemical structure. Antibiotics, containing carboxylic groups such as cephalothin, carbenicillin and cefamandol, were better incorporated than antibiotics lacking these groups. A bacterial inhibition test on Staphylococcus aureus bacteria showed inhibition of growth for all antibiotics that were released from the CHA coating. A release test was conducted in phosphate buffer saline PBS at pH 7.4 and 37 degrees C and showed that antibiotics containing carboxylic groups like cephalothin were slower released from the CHA coating than others. These results suggest that certain antibiotics are able to bind/chelate with calcium, resulting in a better incorporation into the CHA coating and a slower release. Antibiotics incorporated in CHA coatings on titanium implants might be used to prevent post-surgical infections and to promote bone-bonding of orthopedic devices.

Anti-Bacterial Agents↗

Evaluation of two biodegradable polymeric systems as substrates for bone tissue engineering.

The aim of this study was to evaluate two biodegradable polymeric systems as scaffolds for bone tissue engineering. Rat bone marrow cells were seeded and cultured for 1 week on two biodegradable porous polymeric systems, one composed of poly(ethylene glycol)-terephthalate/poly(butylene terephthalate) (PEGT/PBT) and the other composed of cornstarch blended with poly(epsilon-caprolactone) (SPCL). Porous hydroxyapatite granules were used as controls. The ability of cells to proliferate and form extracellular matrix on these scaffolds was assessed by a DNA quantification assay and by scanning electron microscopy examination; their osteogenic differentiation was screened by the expression of alkaline phosphatase. In addition, the in vivo osteogenic potential of the engineered constructs was evaluated through ectopic implantation in a nude mouse model. Results revealed that cells were able to proliferate, differentiate, and form extracellular matrix on all materials tested. Moreover, all constructs induced abundant formation of bone and bone marrow after 4 weeks of implantation. The extent of osteogenesis (approximately 30% of void volume) was similar in all types of implants. However, the amount of bone marrow and the degree of bone contact were higher on HA scaffolds, indicating that the polymers still need to be modulated for higher osteoconductive capacity. Nevertheless, the findings suggest that both PEGT/PBT and SPCL systems are excellent candidates to be used as scaffolds for a cell therapy approach in the treatment of bone defects.

Alkaline Phosphatase↗

Biomimetic calcium phosphate coatings on Polyactive 1000/70/30.

Precalcification of Polyactive 1000/70/30 with a biomimetic calcium phosphate coating is expected to enhance the bioactivity of this biodegradable polymer for the application as bone filler or scaffold of bone tissue engineering. This study presents a 1-day one-step incubation method to obtain either amorphous or bone-like apatitic calcium phosphate coating on Polyactive 1000/70/30. Either dense plates or three-dimensional porous blocks of the polymer were incubated in a simplified but concentrated simulated body fluid-derived solution at 37 degrees C. By bubbling CO2 gas, a solution was prepared with calcium and phosphate ion concentrations five times of that of regular simulated body fluid. With controlled stirring, the CO2 was released out of the solution and exchanged by air. The pH of the solution increased to induce coating formation. Adjusting stirring rate and CO2/air exchange rate controlled the process kinetics. The reaction kinetics had little influence on the crystallographic structure of the final coating mineral for a given solution composition as shown by Fourier transform infrared spectroscopy and X-ray diffraction. However, the interface structure between the coating and substrate was kinetics-dependent. A fast precipitation condition resulted in a uniform but superficial calcification pattern at the surface of polymer. A slow process by selecting either a slow stirring or a slow CO2/air exchange, on the contrary, induced a localized but deep inside calcification pattern. A tensile test showed no statistically significant difference in the mechanical properties among uncoated and coated polymers. The cracking behavior of coatings from different kinetics, however, exhibited different manners, as can be attributed to different interface structures and interfacial strengths.

Bone Substitutes↗