PubMed Health⌕ Search

Biomedical subjects

J Biederer

Publications and source records attributed to J Biederer.

At least 19 recordsLinked to original sources

Detection of small pulmonary nodules in high-field MR at 3 T: evaluation of different pulse sequences using porcine lung explants.

To evaluate two MR imaging sequences for the detection of artificial pulmonary nodules inside porcine lung explants. 67 agarose nodules ranging 3-20 mm were injected into ten porcine lungs within a dedicated chest phantom. The signal on T1-weighted images and radiopacity were adjusted by adding 0.125 mmol/l Gd-DTPA and 1.5 g/l of iodine. A T1-weighted three-dimensional gradient-echo (T1-3D-GRE; TR/TE:3.3/1.1 ms, slice:8 mm, flip-angle:10 degrees ) and a T2-weighted half-Fourier fast-spin echo sequence (T2-HF-FSE; TR/TE:2000/66 ms, slice:7 mm, flip-angle:90 degrees ) were applied in axial orientation using a 3-T system (Intera, Philips Medical Systems, Best, The Netherlands), followed by CT (16x0.5 mm) as reference. Nodule sizes and locations were assessed by three blinded observers. In nodules of >10 mm, sensitivity was 100% using 3D-GRE-MRI and 94% using the HF-FSE sequence. For nodules 6-10 mm, the sensitivity of MRI was lower than with CT (3D-GRE:92%; T2-HF-FSE:83%). In lesions smaller than 5 mm, the sensitivity declined to 80% (3D-GRE) and 53% (HF-FSE). Small lesion diameters were overestimated with both sequences, particularly with HF-FSE. This study confirms the feasibility of 3 T-MRI for lung nodule detection. In lesions greater than 5 mm, the sensitivity of the 3D-GRE sequence approximated CT (>90%), while sensitivity and PPV with the HF-FSE sequence were slightly inferior.

Animals↗

[MRI in staging of lung cancer].

PURPOSE: Overview of magnetic resonance imaging (MRI) in staging of lung cancer. MATERIAL AND METHODS: Currently available methods of imaging lung cancer, lymph node and distant metastases by MRI are explained. At present, MRI is mainly used in the detection of cerebral metastases and assessment of infiltration of the thoracic wall and of the mediastinum. The capabilities of T2-weighted single-shot TSE (HASTE) and T1-weighted 3D gradient echo techniques (VIBE) are demonstrated. RESULTS: With the advent of new fast sequences like HASTE and VIBE the spatial resolution comes close to that of computed tomography but with an outstanding soft tissue contrast and without radiation exposure. The introduction of lymph node specific contrast media will improve sensitivity and specificity in N staging. Additionally, whole-body MRI is capable of detecting distant metastases, in particular in the organs at risk, i.e. brain, upper abdomen and musculoskeletal system. CONCLUSION: MRI is gaining importance as part of a multimodal imaging approach for staging of lung cancer.

Humans↗

Reproducible Simulation of Respiratory Motion in Porcine Lung Explants.

PURPOSE: To develop a model for exactly reproducible respiration motion simulations of animal lung explants inside an MR-compatible chest phantom. MATERIALS AND METHODS: The materials included a piston pump and a flexible silicone reconstruction of a porcine diaphragm and were used in combination with an established MR-compatible chest phantom for porcine heart-lung preparations. The rhythmic inflation and deflation of the diaphragm at the bottom of the artificial thorax with water (1 - 1.5 L) induced lung tissue displacement resembling diaphragmatic breathing. This system was tested on five porcine heart-lung preparations using 1.5T MRI with transverse and coronal 3D-GRE (TR/TE = 3.63/1.58, 256 x 256 matrix, 350 mm FOV, 4 mm slices) and half Fourier T2-FSE (TR/TE = 545/29, 256 x 192, 350 mm, 6 mm) as well as multiple row detector CT (16 x 1 mm collimation, pitch 1.5, FOV 400 mm, 120 mAs) acquired at five fixed inspiration levels. Dynamic CT scans and coronal MRI with dynamic 2D-GRE and 2D-SS-GRE sequences (image frequencies of 10/sec and 3/sec, respectively) were acquired during continuous "breathing" (7/minute). The position of the piston pump was visually correlated with the respiratory motion visible through the transparent wall of the phantom and with dynamic displays of CT and MR images. An elastic body splines analysis of the respiratory motion was performed using CT data. RESULTS: Visual evaluation of MRI and CT showed three-dimensional movement of the lung tissue throughout the respiration cycle. Local tissue displacement inside the lung explants was documented with motion maps calculated from CT. The maximum displacement at the top of the diaphragm (mean 26.26 [SD 1.9] mm on CT and 27.16 [SD 1.5] mm on MRI, respectively [p = 0.25; Wilcoxon test]) was in the range of tidal breathing in human patients. CONCLUSION: The chest phantom with a diaphragmatic pump is a promising platform for multi-modality imaging studies of the effects of respiratory lung motion.

Animals↗

Fast T1- and T2-weighted pulmonary MR-imaging in patients with bronchial carcinoma.

PURPOSE: A prospective study to evaluate the diagnostic potential and limitations of three fast MRI sequences in patients with bronchial carcinoma based on the comparison with spiral CT. MATERIAL AND METHODS: Three fast chest MRI sequences from 20 patients with central or peripheral bronchial carcinoma were evaluated by two observers for relation of tumour to adjacent structures, lymph node enlargement, additional pulmonary lesions and artefacts. The information from MR-imaging was compared with the results from spiral CT. MRI comprised a T1-3D-GRE breath-hold examination ("VIBE", TR/TE 4.5/1.9 ms, flip-angle 12 degrees , matrix 502 x 512, 2.5 mm coronal slices), a breath-hold, T2-HASTE sequence (TR/TE 2000/43 ms, matrix 192 x 256, 10 mm coronal slices) and a respiration-triggered T2-TSE sequence (TR/TE 3000-6000/120 ms, matrix 270 x 512, 6 mm transverse slices). The FOV was adapted individually (380-480 mm). RESULTS: The presence of the primary bronchial carcinoma and infiltration of thoracic structures by tumour tissue could be demonstrated by all sequences. VIBE sequence was more suitable for detecting small pulmonary nodules than the other MRI examinations, but compared to CT still 20% of these lesions were missed. Contrary to VIBE and T2-weighted TSE scans, HASTE sequence was limited in imaging mediastinal lymph nodes due to missing relevant findings in 2/20 patients. HASTE images significantly provided the lowest rate of artefacts in imaging lung parenchyma (P < 0.001 in peripheral parenchyma), but spatial resolution was limited in this sequence. Concerning the differentiation between tumour and adjacent atelectasis (n = 8), T2-weighted TSE imaging was superior to CT and VIBE in all cases and to HASTE sequence in 4/8 patients. CONCLUSION: The combination of VIBE and HASTE sequence allows for an adaequate imaging of thoracic processes in patients with bronchial carcinoma, limited only in visualizing small pulmonary nodules. To obtain more detail resolution and to differentiate tumour tissue from adjacent atelectasis, T2-TSE examination may be added in selected cases.

Aged↗

Ex-vivo injection technique for implanting solid pulmonary nodules into porcine lungs for multi-slice CT.

PURPOSE: To develop a method for generating realistic pulmonary nodules that equal small pulmonary metastases and granulomas. MATERIALS AND METHODS: A total of 70 artificial lesions were introduced into 5 inflated porcine lungs inside a dedicated chest phantom by high pressure injection of a fat-wax-Lipiodol mixture and scanned with 16-slice computed tomography (CT). Image evaluation by two experienced radiologists included analysis of morphology, nodule size and density. RESULTS: The median nodule density was 78.8 Hounsfield units (HU), with 54 of 70 nodules (77.14 %) judged typical of small lung metastases. CONCLUSION: Without inducing visible damage of lung parenchyma, the injection technique produces highly realistic pulmonary nodules for morphometry or nodule detection with CT.

Animals↗

[Inflammatory aortic arch syndrome: contrast-enhanced, three-dimensional MR angiography in stenotic lesions].

PURPOSE: To determine the value of contrast-enhanced, three-dimensional MR angiography for the evaluation of stenotic and occlusive vascular lesions in inflammatory aortic arch syndrome. MATERIALS AND METHODS: 14 patients with inflammatory aortic arch syndrome (giant cell arteritis: n = 8, Takayasu arteritis: n = 4, ankylosing spondylitis: n = 1 sarcoidosis: n = 1) underwent MR angiography of the aortic arch and the supra-aortic vessels (n = 15, 2 patients were examined twice) and of the abdominal aorta (n = 2). MRA was performed using a 3D-FLASH sequence (TR/TE 4.6/1.8 ms, flip angle 30 (3)) on a 1.5T system. MRA imaging was compared with the findings of DSA, which served as gold standard. RESULTS: In a total of 467 examined vascular territories, DSA revealed 50 stenoses and 35 occlusions. All lesions were detected by MRA. In 23 segments, the degree of stenosis was overestimated by MRA. Sensitivity and specificity of MRA were 100 % and 94.3 %, positive and negative predictive values were 73.6 and 100 %, and the accuracy was 95.1 %. CONCLUSIONS: Despite a tendency to overestimate stenoses, contrast-enhanced three-dimensional MR angiography is a valid, non-invasive technique in the assessment of inflammatory aortic arch syndrome.

Adult↗

[The role of magnetic resonance imaging in the preoperative evaluation of the peripancreatic vasculature in pancreas carcinoma].

PURPOSE: To evaluate the accuracy of magnetic resonance angiography (MRA) to predict vascular involvement in pancreas carcinoma. MATERIALS AND METHODS: This prospective trial included 42 patients with suspected pancreas carcinoma. All patients underwent MRA, different tomographic sequences (MRI) and surgery. Peripancreatic vessels were analyzed for vascular involvement, with the tumor infiltration graded on a scale of 0 to 4 (grade 0 - 4). The imaging findings were correlated with surgery and histopathology. RESULTS: The sensitivity of MRA to predict vascular involvement was 61 % (19 of 31 evaluated vessels) and the specificity 97 % (148 of 153). Sensitivity and specificity for axial MRI were both 94 % (29 of 31 and 144 of 153 evaluated vessels). The difference in the sensitivities of MRA and MRI was statistically significant (p < 0.01). Vascular involvement was correctly graded in 58 % (18 of 31) by MRA and in 74 % (23 of 31) by MRI. CONCLUSION: MRA alone is not sufficient to diagnose vascular involvement in pancreas carcinoma, but provides an adequate overview of the vascular anatomy. A combined protocol of MRA and MRI is needed for an acceptable evaluation of the peripancreatic vessels.

Aged↗

Correlation between HRCT findings, pulmonary function tests and bronchoalveolar lavage cytology in interstitial lung disease associated with rheumatoid arthritis.

A prospective study correlating high-resolution computed tomography (HRCT), lung function tests (PFT) and bronchoalveolar lavage (BAL) cytology in patients with interstitial lung disease (ILD) associated with rheumatoid arthritis (RA). Fifty-three RA patients with suspected ILD (19 men, 34 women) underwent 71 HRCT (14 of 53 with sequential HRCT, mean follow-up 24.3 months). The HRCT evaluation by two observers on consensus included a semi-quantitative characterisation of lesion pattern and profusion on representative anatomical levels. Fifty-two HRCT were followed by PFT and BAL. Agreement or discordance of HRCT-, PFT- and BAL findings were analysed with Pearson's correlation, kappa score and McNemar's test. Tobacco-fume exposure was estimated in pack years. Smoking/non-smoking groups were compared with Student's t test. In 49 of 53 patients, HRCT was suggestive of ILD associated with RA (66 of 71 HRCT). Reticular lesions were found in 40 of 53 patients, in 15 of 40 presenting as mixed pattern with ground-glass opacities (GGO). Pure reticular patterns predominated in patients with long duration of ILD (p>0.01). Pure GGO were not observed. Lesion profusion was highly variable and correlated moderately negative with diffusion capacity (mean 88.2% (SD +/- 20.9%); r=-0.54; p<0.001) and very weak with vital capacity and FEV1 (mean values 92.2% (SD +/- 18.3%); r=-0.27; p<0.05 and 89.8% (SD +/- 17.5%); r=-0.31; p<0.01). In patients with GGO, BAL differentials tended towards neutrophilia (kappa=0.39; p=0.04; McNemar test p>0.2), but not towards lymphocytosis (kappa=0.10; p=0.23; McNemar test p>0.2). Differences in smoking history were not significant (p>0.1). The HRCT appears most appropriate for the detection and follow-up of ILD associated with RA. The PFT and BAL correlate only partially with lesion profusion or grading on HRCT, but they contribute valuable information about dynamic lung function and differential diagnoses (pneumonia, medication side effects).

Aged↗

Percutaneous management of occlusive arterial disease associated with vasculitis: a single center experience.

The purpose of this study was to evaluate the safety and effectiveness of percutaneous transluminal angioplasty for occlusive arterial disease associated with vasculitis. Eleven patients (10 women, 1 man; ages 35-82 years) with the diagnosis of vasculitis of the large vessels underwent interventional treatment during intraarterial angiography. The causes included giant cell arteritis (n = 8) and Takayasu arteritis (n = 3). Thirty-three occlusive lesions (including brachiocephalic and renal arteries, and arteries of upper and lower extremities) were treated with balloon angioplasty and/or stent placement. Follow-up included clinical examination, angiography, and color duplex ultrasound. Technical success was 100% (25/25) for stenoses and 50% (4/8) for occlusive lesions, representing all lesions combined from different anatomic locations. Dissection (n = 3) and arterial rupture with retroperitoneal hematoma (n = 1) was found in three patients. During follow-up (mean 12 months), restenoses (n = 8) and re-restenoses (n = 1) occurred in 8 vascular areas. Three of these lesions were treated with repeated PTA (n = 4). The cumulative primary clinical success rate was 67.6%, cumulative secondary success rate 74.4%, and cumulative tertiary success rate 75.9%. Interventional therapy in systemic vasculitis provides promising results in technical success rates and followup. Angioplasty may result in arterial injury, but the rate of complications is low.

Adult↗

[Radiology of the primary systemic vasculitides].

Determination of disease extension and disease activity are in the foreground of diagnostic imaging in vasculitides. There are several radiologic modalities available each having specific indications. Magnetic resonance imaging (MRI) readily depicts granulomas and mucosal inflammations in the paranasal sinuses, nasal cavity and orbits. Computed tomography detects osseous lesions of the skull. Due to its superb sensitivity MRI is an established screening modality for CNS vasculitides, although there are limitations with regard to specificity. In spite of its limited accuracy in most institutions angiography is still required for radiological confirmation of CNS vasculitis. Perfusion and diffusion MR-imaging may combine the advantages of "conventional" MRI and angiography. By now the method is not fully validated for vasculitides, however. Vascular disease in Takayasu's arteritis and in giant cell arteritis involving predominantly large and medium sized vessels is readily diagnosed by non invasive magnetic resonance angiography. Percutaneous transluminal angioplasty has proven to be an effective and save therapeutic modality for the cure of vascular stenoses and occlusions. Plain film radiography in two planes is the established modality for pulmonary imaging. In pulmonary vasculitides a more thorough analysis of lung disease is provided by high resolution computed tomography. Diagnostic imaging does substantially assist in the interdisciplinary management of patients suffering from vasculitides.

Adolescent↗

[Early results with a monorail-stent-balloon device for endovascular treatment of renal artery stenosis].

OBJECTIVE: To evaluate the technical feasibility of a new monorail-stent-balloon device for treatment of renal artery stenosis (RAS). PATIENTS AND METHODS: During a study period of 18 months, 38 patients with proven RAS in 41 cases (hypertension n = 36, renal insufficiency n = 13) and indication for stenting (calicified ostial lesions n = 35, insufficient PTA n = 4, dissection n = 2) were enrolled into this prospective evaluation. Pre-mounted stents (Rx-Herculink(TM) 5 mm = 13, 6 mm = 34, 7 mm = 1) were implanted a transfemoral (n = 35) or transbrachial approach (n = 6). Mean grade and lengths of stenosis measured were 88 % plus minus 10 and 9 mm plus minus 5. RESULTS: Renal stent implantation was technically successful in all cases (100 %). In 7 cases a second stent had to be implanted to cover the entire lesion. The transstenotic pressure drop decreased from 88 mmHg plus minus 10 before to 1 mmHg plus minus 1.8 after the procedure. Remaining stenosis measured 0.7 % plus minus 4.2. Serum creatine levels decreased from 1.9 mm/dl to 1.5 mg/dl (n. s.), blood pressure decreased from 178/94 mmHg to 148/79 mmHg (p < 0.0001) after the intervention. Primary and secondary patency rates at 6 months were 72 % (Standard Error 9.8 %) and 77 (% (Standard Error 9.2 %), respectively. CONCLUSION: With the used monorail-stend-balloon device a technically easy, secure and exact renal stent placement is guaranteed, patency rates are similar to those described in the current literature.

Adult↗

[Alar ligaments: radiological aspects in the diagnosis of patients with whiplash injuries].

Post-traumatic changes of the alar ligaments have been proposed to be the cause of chronic pain in patients after whiplash injury of the cervical spine. In addition to an asymmetric dens position, widening of the atlantodental distance to more than 12 mm can be an indirect sign of an alar ligament rupture. CT is recommended for detection of a avulsion fracture of the occipital condyle. Isolated ruptures of the alar ligaments are best visualized on MRI. In patients with chronic impairments after whiplash injuries changes of the alar ligaments on MRI must be differentiated from normal variants in healthy individuals.

Adult↗

[High-resolution computed tomography of the lungs in pediatric patients].

Since the introduction of the high-resolution technique more than ten years ago, HRCT has become an established modality for diagnosing diseases of the respiratory system. This is especially true for the diagnosis of lung diseases in adults. Experience in HRCT of the lungs is limited in pediatric patients. This review gives an overview of frequent and less frequent HRCT findings in pulmonary diseases in childhood. A purely reticular pattern is rarely observed in infants. Pulmonary diseases associated with overinflation are relatively frequent. Paired inspiratory-expiratory scans combine morphological analysis with functional information and have improved the diagnosis of air trapping, e. g. in post-infectious bronchiolitis obliterans or bronchopulmonary dysplasia. Especially in children the high radiation exposure is a problem. Even when applying a low-dose protocol the radiation dose of HRCT will still exceed the dose of a chest X-ray by 100 times. The indication for pediatric pulmonary HRCT is limited to selected cases and it should be decided in agreement with the pediatric radiologists and the pediatric pulmonologists.

Adolescent↗

[Sensitivity of MRI in detecting alveolar Infiltrates: Experimental studies].

PURPOSE: An experimental study using porcine lung explants and a dedicated chest phantom to evaluate the signal intensity of artificial alveolar infiltrates with T 1 - and T 2 -weighted MRI sequences. MATERIAL AND METHODS: 10 porcine lung explants were intubated, transferred into the cavity of a MRI-compatible chest phantom and inflated by continuous evacuation of the artificial pleural space. All lungs were examined with MRI at 1.5 T before and after intra-tracheal instillation of either 100 or 200 ml gelatine-stabilised liquid to simulate alveolar infiltrates. MR-examination comprised gradient echo (2D- and 3D-GRE) and fast spin echo sequences (T 2 -TSE and T 2 -HASTE). The signal intensity of lung parenchyma was evaluated at representative cross sections using a standardised scheme. Control studies were acquired with helical CT. RESULTS: The instilled liquid caused patchy confluent alveolar infiltrates resembling the findings in patients with pneumonia or ARDS. CT revealed typical ground-glass opacities. Before the application of the liquid, only T 2 -HASTE and T 2 -TSE displayed lung parenchyma signals with a signal/noise ratio of 3.62 and 1.39, respectively. After application of the liquid, both T 2 -weighted sequences showed clearly visible infiltrates with an increase in signal intensity of approx. 30 % at 100 ml (p < 0.01) and 60 % at 200 ml (p < 0.01). With 2D- and 3D-GRE the infiltrates were not visible, although the lung parenchyma signal increase was statistically significant. On 2D-GRE the increase in signal intensity reached 0.74 % (p = 0.32) after 100 ml and 5.6 % (p < 0.01) after 200 ml (for 3D-GRE: 2.2 % [p = 0.02] at 100 ml and 4.4 % at 200 ml [p < 0.01]). The CT controls revealed a significant increase of lung density of 17 H.E. at 100 ml (p = 0.02) and 75 H.E. at 200 ml (p < 0.01). CONCLUSIONS: MRI with T 2 -weighted sequences detects artificial alveolar infiltrates with high signal intensity and may be a highly sensitive tool to detect pneumonia in patients.

Animals↗

MR imaging of the neural foramina of the cervical spine. Comparison of 3D-DESS and 3D-FISP sequences.

PURPOSE: To assess whether a single three-dimensional double-echo steady state (3D-DESS) sequence can produce equivalent results when compared to a 3D free induction with steady precession (3D-FISP) sequence for the evaluation of the neural foraminal diameter and structures. MATERIAL AND METHODS: Five phantoms were imaged on CT with 3-mm axial slices followed by reformatted axial 3D-DESS and 3D-FISP sequences. In addition, 3D-DESS and 3D-FISP sequences of 20 healthy subjects were compared with regard to image quality, differentiation between vertebrae and discs, differentiation between discs and neural foramina, and differentiation between vertebrae and neural foramina. RESULTS: Compared with CT, 3D-DESS and 3D-FISP sequences consistently underestimated the diameters of the neural foramina. The mean difference values for the 3D-DESS was 12.8%, compared to 9.5% for the 3D-FISP sequence. Concerning the in vivo studies, the 3D-DESS sequence was superior but not statistical significant to the 3D-FISP sequence with regard to image quality, differentiation between vertebrae and discs, differentiation between discs and neural formina, and identification of the nerve roots. CONCLUSION: The 3D-DESS sequence is moderately accurate in the evaluation of the neural foraminal size. Compared to the 3D-FISP sequence, the 3D-DESS sequence is compatible concerning the image quality, differentiation between the cervical vertebrae and discs, and between the discs and neural foramina.

Adult↗

Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering.

The aim of this study was to evaluate feasibility and limitations of two MR sequences for imaging of the lung using a semi-quantitative rating scale. Ten healthy volunteers were assessed with a breath-hold T1-weighted gradient-recalled-echo (TR/TE=129/2.2 ms, matrix 173 x 256) and a T2-weighted turbo spin-echo (TSE) sequence with respiratory triggering (TR/TE=3000-5000/120 ms, matrix 270 x 512) in axial 6-mm slices. The T1-weighted GRE protocol included a pre-saturation pulse over the mediastinal structures. Artefacts and resolution of vessel/airway structures in each lung segment were evaluated by two observers (10 volunteers, 180 segments). Cardiac and vessel pulsation artefacts predominated on T1-weighted GRE, respiration artefacts on T2-weighted TSE (lingula and middle lobe). Pre-saturation of the mediastinum reduced pulsation artefacts on T1-weighted GRE. T1-weighted GRE images were improved by bright flow signal of vessels, whereas image quality of T2-weighted TSE was reduced by black-blood effects in central parts of the lung. Delineation of lung periphery and the mediastinum was superior with T2-weighted TSE. Segmental/sub-segmental vessels (up to fourth/fifth order) and bronchi (up to third order) were identified. All 180 lung segments were imaged in diagnostic quality with at least one of the two sequences (T1-weighted GRE not diagnostic in 9 of 180, T2-weighted TSE in 4 of 180). Both sequences were found to be complementary: superior identification of gross lung anatomy with T1-weighted GRE and higher detail resolution in the periphery and the mediastinum with T2--weighted TSE.

Adult↗

[Vasculitis--interdisciplinary diagnosis: radiology].

Determination of disease extension and disease activity are in the foreground of diagnostic imaging in vasculitides. There are several radiologic modalities available each having specific indications. Magnetic resonance imaging (MRI) readily depicts granulomas and mucosal inflammations in the paranasal sinuses, nasal cavity and orbits. Computed tomography detects osseous lesions of the skull. Due to its superb sensitivity MRI is an established screening modality for CNS vasculitides, although there are limitations with regard to specificity. In spite of its limited accuracy in most institutions angiography is still required for radiological confirmation of CNS vasculitis. Perfusion and diffusion MR-imaging may combine the advantages of 'conventional' MRI and angiography. By now the method is not fully validated for vasculitides, however. Vascular disease in Takayasu's arteritis and in giant cell arteritis involving predominantly large and medium sized vessels is readily diagnosed by non invasive magnetic resonance angiography. Percutaneous transluminal angioplasty has proven to be an effective and save therapeutic modality for the cure of vascular stenoses and occlusions. Plain film radiography in two planes is the established modality for pulmonary imaging. In pulmonary vasculitides a more thorough analysis of lung disease is provided by high resolution computed tomography. Diagnostic imaging does substantially assist in the interdisciplinary management of patients suffering from vasculitides.

Angioplasty↗