Bioethics, the Surviving Sepsis Campaign and the industry.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to J Bion.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Multiple-antibiotic-resistant Acinetobacter baumanii, including meropenem resistance, was first isolated from a patient in the general intensive care unit of a tertiary-referral university teaching hospital in Birmingham in December 1998. Similar strains were subsequently isolated from 12 other patients, including those on another intensive care unit within the hospital. The outbreak followed an increase in the use of meropenem in both the units. Environmental screening revealed the presence of the multiple-resistant Acinetobacter species on fomite surfaces in the intensive care unit and bed linen. The major source appeared to be the curtains surrounding patients' beds. Typing by pulsed field gel electrophoresis demonstrated that the patients' isolates and those from the environment were indistinguishable. Rigorous infection control measures including increased frequency of cleaning of the environment with hypochlorite (1000 ppm) and twice-weekly changing of curtains were implemented, along with restriction of meropenem use in the units. Isolation of the multiple-resistant Acinetobacter spp. subsequently diminished and it was not detected over a follow-up period of 18 months. To our knowledge, this is the first reported outbreak of carbapenem-resistant Acinetobacter spp. from the UK. This outbreak also highlights environmental sources, particularly dry fabrics such as curtains, as an important reservoir for dissemination of acinetobacters.
Explore the source record for details and available documents.
OBJECTIVES: To test the feasibility of using a nominal group technique to establish clinical and health services research priorities in critical care and to test the representativeness of the group's views. DESIGN: Generation of topics by means of a national survey; a nominal group technique to establish the level of consensus; a survey to test the representativeness of the results. SETTING: United Kingdom and Republic of Ireland. SUBJECTS: Nominal group composed of 10 doctors (8 consultants, 2 trainees) and 2 nurses. MAIN OUTCOME MEASURE: Level of support (median) and level of agreement (mean absolute deviation from the median) derived from a 9 point Likert scale. RESULTS: Of the 325 intensive care units approached, 187 (58%) responded, providing about 1000 suggestions for research. Of the 106 most frequently suggested topics considered by the nominal group, 37 attracted strong support, 48 moderate support and 21 weak support. There was more agreement after the group had met-overall mean of the mean absolute deviations from the median fell from 1.41 to 1.26. The group's views represented the views of the wider community of critical care staff (r=0.73, P<0.01). There was no significant difference in the views of staff from teaching or from non-teaching hospitals. Of the 37 topics that attracted the strongest support, 24 were concerned with organisational aspects of critical care and only 13 with technology assessment or clinical research. CONCLUSIONS: A nominal group technique is feasible and reliable for determining research priorities among clinicians. This approach is more democratic and transparent than the traditional methods used by research funding bodies. The results suggest that clinicians perceive research into the best ways of delivering and organising services as a high priority.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We report a case of massive pulmonary embolism occurring at the time of graft reperfusion in a patient undergoing orthotopic liver transplantation. The clinical diagnosis of pulmonary embolus was aided by on-table echocardiography. Cardiopulmonary bypass and surgical embolectomy prevented her death. We discuss the differential diagnosis, possible aetiology of pulmonary embolism in this context and subsequent management.
Though there are reasonable data to suggest that certain countries, such as the United States, spend considerably more money on the provision of critical care services than others, there is little information regarding the added benefits accrued with this additional expense. Studies to date have suggested little if no difference in outcome but have been limited in their size, design, and choice of outcome measures. Furthermore, significant underlying societal priorities and philosophy may dictate that the optimal critical care delivery system is different for different countries. With the increasing availability of large patient databases, however, it will be more feasible in the future to design and conduct assessments of critical care delivery systems between countries taking appropriate account of the choice of study design, definition of at-risk populations, and choice of valuable measures of output and cost. The results of such assessments will hopefully drive wiser decision making in the design and management of critical care delivery systems worldwide.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVE: To compare the performance of three severity of illness scoring systems used commonly for intensive care unit (ICU) patients in a large international data set. The systems analyzed were versions II and III of the Acute Physiology and Chronic Health Evaluation (APACHE) system, versions I and II of the Simplified Acute Physiology Score (SAPS), and versions I and II of the Mortality Probability Model (MPM), computed at admission and after 24 hrs in the ICU. DESIGN: A multicenter, multinational cohort study. SETTING: One hundred thirty-seven ICUs in 12 European and North American countries. PATIENTS: During a 3-month period, 14,745 patients were consecutively admitted to 137 ICUs enrolled in the study. INTERVENTIONS: Collection of information necessary to compute the APACHE II and APACHE III scores, SAPS I and SAPS II, and MPM I and MPM II scores. Patients were followed until hospital discharges. Statistical comparison, including indices of calibration (goodness-of-fit) and discrimination (area under the receiver operating characteristic curve). MEASUREMENTS AND MAIN RESULTS: Despite having acceptable receiver operating characteristic areas, the older versions of the systems analyzed (APACHE II, SAPS, and MPM I computed at admission-MPM I computed after 24 hrs in the ICU) demonstrated poor calibration for the whole database. The new versions of the systems (SAPS II and MPM II) were superior to their older counterparts. This superiority is reflected by larger receiver operating characteristic areas and better fit. The APACHE III system improved its receiver operating characteristic area compared with the APACHE II system, which showed the best fit of the old systems analyzed. CONCLUSIONS: The new versions of the severity systems analyzed (APACHE III, SAPS II, MPM II) perform better than their older counterparts (APACHE II, SAPS I, and MPM I). APACHE II, SAPS II, and MPM II show good discrimination and calibration in this international database.
OBJECTIVE: To quantify the precision and bias for two standard blood gas analyzers when measuring PCO2 in five different test solutions (blood, normal saline, human albumin solution, succinylated gelatin 4%, and Hartmann's solution). DESIGN: A comparative laboratory study of two blood gas analyzers measuring known PCO2 in test solutions prepared with a thin film tonometer. MEASUREMENTS: The PCO2 was determined simultaneously in both blood gas analyzers. The precision and bias for both machines were calculated from the measured PCO2. RESULTS: Analyzer 1 showed a negative bias of between 66.4% and 39.2% when measuring PCO2 in saline. Under the same conditions, analyzer 2 showed a negative bias of between 17.7% and 17.9% for PCO2 in the mid- and high ranges of PCO2, but a positive bias in the low range. Both machines measured PCO2 with satisfactory bias and precision in blood. The use of succinylated gelatin 4% as a test solution improved the bias and precision of both machines. CONCLUSIONS: Because of the large bias and precision, neither of these machines is suitable for measuring PCO2 in saline solution. The use of succinylated gelatin 4% as a test solution improves the bias and precision of both machines and we favor this solution for nasogastric tonometry. Even with succinylated gelatin 4%, there is a large negative bias with analyzer 1 and our preference is to use analyzer 2. We recommend that other workers review critically the performance of blood gas electrode systems when measuring PCO2 in saline solution. Because of varying performance of "standard" machines, we also recommend that each institution determine its own reference range for intramucosal pH.
The United Kingdom spends less on health care than most other Western nations. Consequently, intensive care, which is seen as a service rather than as an independent discipline, has been neglected and under-resourced. Plans to develop intensive care as a multidisciplinary specialty may change the situation. However, the National Health Service is itself undergoing major organizational reforms with the development of an internal market. In addition, competition between hospital trusts may impose cost constraints that prevent the expansion of intensive care facilities and impede regionalization of intensive care services. Severity-adjusted outcomes indicate that the standard of intensive care in the United Kingdom is high, and good outcomes are achieved at comparatively low cost. However, there is evidence that the underfunding of intensive care is resulting in lost opportunities for preventing avoidable morbidity and mortality. Unless a modest increase in funding for intensive and high-dependency care is made available, formal strategies for rationing and triage may have to be adopted.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.