[5 years of "concerted action dose reduction in CT" -- what has been achieved and what remains to be done?].

In May 1998, the German "Concerted Action Dose Reduction in CT" was founded by all parties involved in CT. Its intention was to achieve a significant reduction of the radiation exposure caused by CT, a matter that has increasingly been considered a major challenge since the early nineties. As a result of a number of joint efforts, the essential preconditions have been established by now. The fifth anniversary of the Concerted Action gave rise for both retrospection and outlook on the tasks that have already been accomplished and those that still need to be done. For this purpose, a one-day symposium took place in Berlin on November 4, 2003. The contents of a total of 18 contributions will be outlined here in brief.

Adult↗

[Imaging of the coronary arteries by means of multislice helical CT: optimization of image quality with multisegmental reconstruction and variable gantry rotation time].

PURPOSE: To evaluate the potential of multisegmental reconstruction and variable gantry rotation time for reducing motion-induced artifacts in coronary artery imaging by multislice helical CT. MATERIALS AND METHODS: The data sets of 20 patients (8 with HR < 60 bpm, 12 with HR > 60 bpm) were analyzed. The patients underwent multislice helical CT (Aquilion 8, Toshiba, Otawara, Japan) using the following parameters: 0.5 mm slice thickness, 250 mA, 120 kV, pitch of 0.25 and variable gantry rotation times of 400, 500, or 600 msec. Images were generated by halfscan and multisegmental reconstruction. In 9 coronary segments of each patient, the presence and severity of motion artifacts were assessed and graded on a scale between 5 (no artifacts) and 1 (heaviest artifacts). RESULTS: Diagnostically relevant motion artifacts were rare at low heart rates (< 60 bpm) for both types of image reconstruction (4 % of all segments). Higher heart rates (> 60 bpm) were associated with an increase in motion artifacts on halfscan reconstructions (33% of all segments, p < 0.05) but not on multisegmental reconstructions (4% of all segments). At low heart rates mean image quality did not differ between multisegmental and halfscan reconstruction (4.28 +/- 0.37 vs. 4.22 +/- 0.41; p > 0.05), whereas at higher heart rates image quality was better for multisegmental reconstruction than for halfscan reconstruction (4.23 +/- 0.47 vs. 3.11 +/- 0.63; p < 0.05). CONCLUSION: Multisegmental reconstruction with variable gantry rotation times suppresses motion artifacts and thus improves assessment of the coronary arteries in patients with higher heart rates.

Artifacts↗

[Spatial and temporal resolution with 16-slice computed tomography for cardiac imaging].

The use of the CT scanner for cardiac imaging is mainly influenced by the spatial and temporal resolution that can be achieved with the applied technologies and procedures. The data acquisition with 16 x 0.5 mm scan slice thickness and a special multisegment image reconstruction procedure are a new combination for accurate imaging of the cardiac morphology. A 0.5 mm slice thickness and an overlapping pitch < 0.35 generate an isotropic image voxel of 0.35 x 0.35 x 0.35 mm. The object size of a coronary artery with a diameter of 2.5 mm amounts to a relative spatial blurring factor K (d) of approximately 15 %. The segment reconstruction with 4 segments from 4 consecutive cardiac cycles requires the optimum acquisition time of 50 ms for one frame. The relative exposure factor K (t) with reference to the R-R interval is an appropriate measure to validate the influence of coronary artery movement on the image quality at different heart rates. This relative exposure varies between 10 % and 20 % for a heart rate of 40 to 140 beats per minutes (bpm) and its mean is approximated by a linear trend function with K (t) = 14 %. A constant value in this linear trend function means a constant "blurring" of the imaged coronary arteries, independent of the actual heart rate. Thus, computed tomographic examinations can be carried out for heart rates between 40 and 140 bpm without using beta-blocking medication. Case studies of the 3D reconstruction and curved reformatting of coronary arteries with stents and calcifications show the achievable image quality at different heart rates.

Algorithms↗