Vascular restenosis. Basic science and clinical implications.

Cardiovascular interventions to correct arterial occlusive disease have excellent short-term results, but long-term patency is still seriously compromised by the development of restenosis. This review will provide a portrait of the mechanisms following vascular injury, define the clinical scope of the problem and outline developments of different therapeutical strategies to prevent restenosis.

Angioplasty, Balloon↗

Stent-graft replacement of chronic traumatic aneurysm of the thoracic aorta after blunt chest trauma.

Chronic traumatic aneurysm of the thoracic aorta is an unusual occurrence. Open-chest surgery for repair of chronic traumatic aneurysms results in mortality rate of 5-18%, and a morbidity rate of 11-50% also. The evolution of endovascular technology offers the promise of a new, less invasive method to achieve aneurysm exclusion. A case of chronic traumatic aneurysm of the near isthmus thoracic aorta discovered on a chest X-ray and evaluated with chest computed tomographic scanning is presented. Stent-grafting procedure is described. Stent-grafting in chronic traumatic aneurysm of the thoracic aorta seems to be a viable minimal invasive therapeutic option for traumatic rupture of the aortic isthmus.

Accidents, Traffic↗

Stent jail of the renal arteries in stent graft exclusion of AAA. An in vitro study of 3 different stent types.

BACKGROUND: The success of endoluminal stent grafts (ELG) is critically dependent on secure proximal fixation of the graft. Different types of stent grafts with uncovered proximal portions for transrenal fixation are obtainable. The present in vitro study was designed to elucidate how the flow parameters were altered by stent jail of the renal arteries with respect to different stent design. METHODS: The experiments were performed in an in vitro pulsatile circulation model. An aortic segment with bilateral side branches (like renal arteries) constructed of an ePTFE graft was perfused in the circulation model. The flow measurements were based on the ultrasound transit-time method. By varying the frequency from 30 to 100 bpm the flow parameters were altered and recorded continuously. Renal stent jailing was carried out using different stent types: Gianturco-Z-Stent, Palmaz-Stent, Powerlink Endologix. RESULTS: The flow in the aortic model increased from 1100 ml per minute to 3330 ml per minute depending on the pump frequency. In the control group without stent jail the renal flow was measured between 240 ml per minute up to 810 ml per minute. The ratio of renal flow was between 0.22 and 0.24 of the aortic flow. In the Palmaz group the ratio was between 0.21 and 0.24, in the Gianturco group between 0.23 and 0.25, and in the Powerlink group between 0.24 and 0.25 (unpaired-"t"-test: n.s.). CONCLUSIONS: The covering of the renal arteries and/ or superior mesenteric artery in case of long bared proximal stent raises the question whether the stent jail may result in flow reduction in the arteries covered or not. The present in vitro study demonstrated that the flow in the renal arteries is not decreased by these stent jails.

Aortic Aneurysm, Abdominal↗

[Stent prostheses in abdominal aortic aneurysm--pre-interventional exclusion of aneurysms of the internal iliac artery].

The technical success of endoluminal grafting in AAAs depends on the complete apposition of the fixation points of the stent graft with the proximal and distal aneurysm neck. Approximately 20% of patients presenting with AAAs have concomitant iliac artery aneurysms. To achieve a complete apposition at the distal landing zone without endoleak, intentional occlusion of the internal iliac artery is needed. To evaluate the inherent complications, our results of ELG were compared to those of the bibliography.

Aged↗

Endovascular repair of descending thoracic aortic aneurysms: an early experience with intermediate-term follow-up.

PURPOSE: The purpose of this study was to report an initial experience with the endovascular repair of descending thoracic aortic aneurysm. Complications and intermediate-term morphologic changes were identified with the intent of altering patient selection and device design. METHODS: Endografts were placed into 25 patients at high-risk for conventional surgical repair over a 3(1/2)-year period. Devices were customized on the basis of preoperative imaging information. Follow-up computed tomography scans were obtained at 1, 3, 6, and 12 months and yearly thereafter. Additional interventions occurred in the setting of endoleaks, migration, and aneurysm growth. RESULTS: The overall 30-day mortality rate was 20% (12.5% for elective cases; 33% for emergent cases). There were 3 conversions to open repair. Neurologic deficits developed in 3 patients; 1 insult resulted in permanent paraplegia. Neurologic deficits were associated with longer endografts (P =.019). Three endoleaks required treatment, and 1 fatal rupture of the thoracic aneurysm treated occurred 6 months after the initial repair. Migrations were detected in 4 patients. The maximal aneurysm size decreased yearly by 9.15% (P =.01) or by 13.5% (P =.0005) if patients with endoleaks (n = 3 patients) were excluded. Both the proximal and distal neck dilated slightly over the course of follow-up (P =.019 and P =.001, respectively). The length of the proximal neck was a significant predictor of the risk for endoleakage (P =.02). CONCLUSION: The treatment of descending thoracic aortic aneurysms with an endovascular approach is feasible and may, in some patients, offer the best means of therapy. Early complications were primarily related to device design and patient selection. All aneurysms without endoleaks decreased in size after treatment. Late complications were associated with changing aneurysm morphologic features and device migration. The morphologic changes remain somewhat unpredictable; however, alterations in device design may result in improved fixation and more durable aneurysm exclusion.

Aged↗

Endovascular healing is inadequate for fixation of Dacron stent-grafts in human aortoiliac vessels.

BACKGROUND: migration and kinking of stent-grafts can occur late after endovascular aneurysm repair. It is unknown if endovascular grafts incorporate enough to be permanently anchored. In this report, healing of aortic stent-grafts was assessed in humans. PATIENTS AND METHODS: we retrieved 23 Dacron stent-grafts from patients treated for an aortic aneurysm since 1993. Twelve stent-grafts were explanted at late conversion to open repair and 11 at autopsy. The deaths were unrelated to graft fixation. The median age of the patients was 74 years (IQR 55-84 years) and the grafts were explanted 9 months (1-31 months) after insertion. Microscopic slides were prepared by conventional techniques or by cutting and grinding arterial specimens embedded in plastic with the stent-grafts in situ. RESULTS: the stent-grafts detached readily from the native arteries at surgery or autopsy, except when the stents had hooks or barbs which engaged the vessel wall. A space filled with poorly organised blood components persisted between the graft and the aortic wall 2.5 years after implantation. No firm incorporation of the grafts was observed proximally in the aneurysm neck or distally in the iliac segment. A friable neo-intimal layer covered parts of the luminal aspect of the grafts. CONCLUSIONS: endovascular healing provides poor fixation of Dacron stent-grafts in humans. At present, fixation relies on the mechanical properties of the stent-grafts.

Aged↗

The impact of stent design on proximal stent-graft fixation in the abdominal aorta: an experimental study.

OBJECTIVE: to study the proximal fixation of different aortic stent grafts in comparison to a hand-sewn anastomosis. DESIGN: experimental study. MATERIAL: the infrarenal aorta of 16 human cadavers were exposed, left in situ and transected 3 cm above the aortic bifurcation to mimic an infrarenal aortic neck. Stent grafts were deployed through a sheath 5 cm into the aorta. Ancure, Talent, Vanguard, Zenith and a Palmaz based stent graft were assessed. In addition a polyester graft was anastomosed to the aorta by running sutures. Distal force was applied to the grafts in increments of 0.5 Newton until the stent grafts were completely dislodged from the aorta. The displacement force (DF) was thereby determined. RESULTS: a force of 150 N (140-160) applied to the hand-sewn graft resulted in tearing of the aorta, without breakage of the sutures. The median displacement force was for Talent 4.5 N (1.3-5.5), Vanguard 9.0 N (3. 5-12), Ancure 12.5 N (12-14), Zenith 24 N (23-26.5) and Palmaz 25 N (17-25). Ballooning the stent after deployment improved fixation in some cases. CONCLUSIONS: a sutured anastomosis fixates a graft better than any stent design tested. Hooks and barbs improve the fixation of self-expandable stents. Balloon dilatation of the proximal stent after deployment might increase fixation further. Balloon expandable stents seem to provide good fixation without the use of hooks and barbs.

Aged↗

Midterm changes in aortic aneurysm morphology after endovascular repair.

PURPOSE: To study midterm changes in aortic aneurysm morphology after endovascular aneurysm repair. METHODS: Of 94 patients with abdominal aortic aneurysms (AAAs) treated with endografts between November 1993 and August 1998, 84 were available for follow-up. Patients were evaluated preoperatively by spiral computed tomography (CT) and aortography; in follow-up, spiral CT scanning was performed at 1, 3, and 6 months and semiannually thereafter. Measurements of the aneurysm neck diameter, maximum aneurysm diameter, and the distance from the lowermost renal artery to the aortic bifurcation were made preoperatively and in follow-up. RESULTS: Mean follow-up was 17.5 +/- 1.1 months; 56 (67%) patients were followed for 1 year and 28 (33%) for > or = 2 years. There was a median 2-mm increase (interquartile range [IQR] 0 to 3) in neck diameter at 18 months. However, a > or = 3-mm increase was seen in 18 (46%) of 39 patients examined at 18 months (median 4 mm, IQR 3 to 4, p = 0.0001). The maximum AAA diameter decreased by 9 mm (IQR 4 to 16, p = 0.0003) at 24 months, but after 18 months, no further interval decrease was seen. Aneurysms with a persistent endoleak showed either increasing or unchanged AAA diameters. There was no change in the renal artery to bifurcation distance. CONCLUSIONS: The infrarenal aortic neck appears to dilate after AAA endografting, but only in a subset of patients. Shrinkage of aneurysms after successful stent-grafting seems to stop after 18 months, implying that the only indication of late failure in the absence of endoleak might be aneurysm enlargement. Graft-related endoleaks are often associated with an increase in aneurysm diameter.

Aged↗

Quality of life before and after endovascular and open repair of asymptomatic AAAs: a prospective study.

PURPOSE: To assess how patients perceive health-related quality of life (HRQOL) after endovascular and open abdominal aortic aneurysm (AAA) repair. METHODS: Forty-two consecutive patients (33 men; mean age 74 years, range 46-81) were assessed prospectively before and after elective endovascular (n = 21) and open (n = 21) AAA repair. Aneurysm morphology dictated the type of repair. The two patient groups were similar regarding age, gender, comorbidities, and cardiopulmonary function. Data concerning surgical trauma were compiled. The Nottingham Health Profile (NHP) score was used to assess the perceived HRQOL (criteria: pain, mobility, sleep, emotion, energy, and isolation) preoperatively and at 5, 30, and 90 days postoperatively. Specific treatment perception questions were added. RESULTS: One patient from each group died, leaving 40 patients to complete the study. Two patients with open repair and 1 patient with endovascular repair were unfit to answer the questionnaire on day 5. The HRQOL improved at 3 months compared with the preoperative values (p < 0.05). No significant difference was found at any time between the open and endovascular groups regarding the NHP score, although the operative time, blood loss, analgesic use, and hospital stay were significantly in favor of endovascular repair. Reinterventions were required in 5 patients with endovascular and 2 patients with open repair. CONCLUSIONS: In general, 3 months after AAA repair, the perceived HRQOL seems better than before treatment. Perceived HRQOL is similar after endovascular and open AAA repair despite greater surgical trauma in open surgery. This may reflect the higher number of reinterventions following endovascular repair but also difficulties in defining HRQOL.

Aged↗

Aneurysm expansion and retroperitoneal hematoma after thrombolysis for stent-graft limb occlusion caused by distal endograft migration.

PURPOSE: To describe a complication of thrombolytic therapy used to treat graft limb occlusion precipitated by distal migration and kinking of an abdominal aortic stent-graft. CASE REPORT: A 5.5-cm abdominal aortic aneurysm (AAA) in a 66-year-old woman was treated with Vanguard bifurcated stent-graft. At the 1-year follow-up, she complained of left leg claudication. Computed tomography (CT) showed a 36% reduction in maximum AAA diameter, but the stent-graft had migrated distally approximately 5 mm, and the left graft limb was occluded. Thrombolysis was initiated, but after approximately 8 hours, abdominal pain began. Emergent CT scanning revealed rapid aneurysm expansion and a retroperitoneal hematoma. Thrombolytic treatment was stopped; transfusions and thrombogenic drugs were given to restore hemodynamic stability. The aneurysm began to decrease in size. The occluded graft limb had been reopened by the lytic therapy, uncovering a stenosis in the native artery distal to the graft limb. Stent placement restored outflow. The retroperitoneal hematoma resolved over time, and the aneurysm sac shrank to its prelytic diameter. The patient is well with a functioning endograft 18 months after the occlusion (30 months after stent-grafting). CONCLUSIONS: Caution must be taken when using thrombolysis in patients with endovascular aortic grafts because unexpected bleeding complications might arise. Thrombectomy, femorofemoral bypass, or stent or stent-graft extensions might be safer alternatives for treating occluded stent-graft limbs.

Aged↗

Distal migration of stent-grafts after endovascular repair of abdominal aortic aneurysms.

PURPOSE: To analyze patients after endovascular repair of abdominal aortic aneurysm (AAA) with respect to distal migration of stent-grafts and its underlying causes. MATERIALS AND METHODS: Sixty-five patients underwent endovascular repair between January 1994 and February 1997. There were seven women and 58 men, with a mean age of 71 years (range, 51-84 years). Three patients died in the perioperative period (one of myocardial infarction and two of multiorgan failure) and two patients died within 4 months of the procedure of non-procedure-related causes. In addition, two patients were followed at another hospital. The remaining 58 patients were followed up with spiral computed tomography scans at 1, 3, and 6 months, and biannually thereafter. Angiography was performed at 1 month and 1 year after the procedure and additionally when deemed clinically necessary. Mean follow-up was 29 months (range, 1-49). Migration more than 5 mm was considered significant. RESULTS: Twenty-six patients (45%) showed distal migration of stent-grafts during follow-up. Mean follow-up time at detection of migration was 13 months (range, 1-36 months). Thirteen cases of migration were ascribed to dilatation of the proximal aneurysmal neck during follow-up. Ten cases of migration were ascribed to causes other than neck dilatation or poor patient selection. In three cases, no obvious cause for the migration was found. The migration was complete in eight cases, leading to late conversion to open surgical repair. On two of these occasions, complete migration lead to aneurysm rupture. In addition, four patients received additional stent-grafts as proximal extensions. CONCLUSIONS: Distal migration of stent-grafts after endovascular AAA repair occurred frequently in this series. Dilatation of the proximal aneurysmal neck is a major cause of distal migration of stent-grafts. Improved proximal fixation is needed to secure long-term durability.

Aged↗

Acute renal impairment due to a primary aortocaval fistula is normalised after a successful operation.

OBJECTIVES: To study renal function in patients with aortocaval fistula, before and after surgery. DESIGN: Retrospective study. MATERIAL AND METHODS: During the last 22 years nine male patients (median age 67, age range 50-72) with spontaneous aortocaval fistula in combination with AAA were operated upon. This constitutes 4% of the patients with ruptured AAA and 1.5% of all patients with AAA. RESULTS: A preoperative diagnosis of aortocaval fistula was established in three of the nine cases. The medium duration of symptoms prior to surgery was 5 days (range 4 h-14 days). The fistula was combined with an extravasating ruptured AAA in only three patients. Seven of the patients had acute renal insufficiency, with creatinine levels of in median 292 mumol (IQR 218-342). Creatinine declined to 172 mumol/l (IQR 170-313) on the fifth postoperative day in uncomplicated cases and to 86 mumol at discharge. One patient died due to multi-organ failure, whereas the other left hospital well and alive with normal renal function. CONCLUSION: Acute preoperative renal insufficiency due to an aortocaval fistula in patients with AAA is often due to venous congestion, and is normalised after successful surgery.

Acute Kidney Injury↗

Selective increase of the contractile response to endothelin-1 in subcutaneous arteries from patients with essential hypertension.

Endothelin-1 has been shown to contribute to basal vascular tone in man. Since endothelin-1 is a potent vasoconstrictor putatively involved in hypertension, we have compared the contractile responses of endothelin-1 and noradrenaline in relation to potassium chloride in subcutaneous resistance arteries from subjects with established essential hypertension with matched controls. Furthermore, with RT-PCR, the occurrence of mRNA for the ETA and ET(B) receptors was shown in the tunica media layer of subcutaneous arteries in controls and hypertensives. The maximum contractile response to endothelin-1 was significantly higher in the subcutaneous arteries of the hypertensives (by 88% with no change in potency) as compared to controls. The responses to noradrenaline, acetylcholine and potassium chloride did not differ between the groups. This selective increase in the contractile response to endothelin-1 might contribute to the development of essential hypertension.

Acetylcholine↗

Endovascular management of the juxtarenal aortic aneurysm: can uncovered stents safely cross the renal arteries?

A short or otherwise suboptimal neck precludes the use of endovascular repair in 30% to 50% of patients with abdominal aortic aneurysms. Stent-graft fixation in an unsuitable neck carries the risk of technical failure owing to development of a proximal endoleak or stent-graft migration. Furthermore, in some patients, the neck dilates postoperatively. Endovascular healing with tissue incorporation into the graft material seems in and of itself insufficient to fixate the stent-graft adequately or to prevent neck dilation. Therefore, neck dilation is often associated with detachment of the stent-graft from the aortic wall, which is followed by the development of a proximal endoleak or stent-graft migration. Fixation of stent-grafts can be improved by placing the proximal stent above one or both of the renal artery orifices. Current experimental and clinical data suggest that renal function is not impaired by suprarenal aortic stents during the first year; however, this finding may not apply to all types of stents. Fixation of stent-grafts also may be improved by using stents with barbs that pierce the aortic wall. Additionally, the force that is exerted on the anchoring device may well be reduced by fully stented grafts with an associated increase in column strength. In the future, the risk of neck dilation and stent-graft dislodgement might also be limited by novel techniques such as laparoscopic banding of the neck or endoluminal stapling devices.

Aortic Aneurysm, Abdominal↗

Persistent collateral perfusion of abdominal aortic aneurysm after endovascular repair does not lead to progressive change in aneurysm diameter.

PURPOSE: To differentiate between the phenomenon of collateral perfusion from a side branch versus graft-related endoleaks after endovascular repair of abdominal aortic aneurysms (AAA), with respect to aneurysm size and prognosis. METHODS: We successfully treated 64 AAA patients with endovascular grafting. We followed all the patients postoperatively with spiral computed tomography at one, three, six and 12 months, and biannually thereafter. We measured aneurysm diameters preoperatively and postoperatively. We calculated preoperatively the relation of maximum aortic diameter (D) to the thrombus-free lumen diameter (L) expressed as an L/D ratio. Median follow-up was 15 months. RESULTS: Sixteen patients had collateral perfusion during follow-up. We successfully treated two patients with embolization. One patient showed resolution of collateral perfusion after we stopped warfarin treatment. Two patients died of unrelated causes during follow-up. One patient was converted to surgical treatment, and two patients showed spontaneous resolution of their collateral perfusion. The group of patients with perfusion showed no statistically significant change of their aortic diameter on follow-up. The group of patients without perfusion showed a median decrease in aortic diameter of 8mm (p < 0.0001) at 18 months postoperatively. The group of patients with perfusion had significantly less thrombus in their aneurysm sac preoperatively than the group without perfusion, as expressed by the L/D ratio (mean L/D 0,61 versus 0,78, respectively; p=0.0021.) CONCLUSION: There was no significant increase in aortic diameter on an average 18 months postoperatively despite persistent collateral perfusion. This may indicate a halted disease progression in the short term. Embolization of collateral vessels is associated with risk of paraplegia. We recommend a conservative approach with close observation if aneurysm diameter is stable.

Adult↗

Reduced pulsatile wall motion of abdominal aortic aneurysms after endovascular repair.

PURPOSE: The reduced size of abdominal aortic aneurysms (AAAs) after endovascular repair suggests lowered intraaneurysmal pressure. In the presence of endoleaks, the size is not decreased. Although postoperative intraaneurysmal pressure is difficult to record, the pulsatile wall motion (PWM) of aneurysms can be measured noninvasively. The aim of this study was to assess the PWM of AAAs before and after endovascular repair and to relate the change in the PWM to aneurysmal size and presence of endoleaks. METHODS: Forty-seven patients underwent endovascular repair of an AAA. The aneurysm diameter and PWM were measured with the use of ultrasonic echo-tracking scans preoperatively; at 1, 3, and 6 months; and thereafter biannually. Fifteen aneurysms developed endoleaks, whereas 32 were completely excluded. The leaks were characterized with the use of computed tomographic scanning and angiography. Median follow-up was 12 months (interquartile range, 5 to 24 months). RESULTS: The preoperative PWM of the aneurysms was 1.0 mm (range, 0.8 to 1.3 mm). After complete endovascular exclusion, the PWM was 25% (range, 16% to 37%) of the preoperative value (p < 0.001), and aneurysm diameter decreased by 8 mm (range, 6 to 14 mm) (p < 0.001). After 18 months, no further diameter reduction occurred. In three patients without endoleaks but with enlarging aneurysms, the postoperative PWM showed less reduction (p < 0.05). Aneurysms with endoleaks showed no diameter decrease, and the postoperative PWM was 50% higher than that in the totally excluded cases (p < 0.01). In five patients with transient endoleaks, the PWM was reduced after leakage ceased (p < 0.05). Leaks of various sources displayed similar PWM. CONCLUSION: The size and PWM of aneurysms are reduced after endovascular repair. The diameter reduction may cease after 1.5 years. Endoleaks are associated with higher PWM than expected. Pressure may be transmitted without evidence of leaks.

Aged↗