PubMed Health⌕ Search

Biomedical subjects

J C Bergquist

Publications and source records attributed to J C Bergquist.

8 recordsLinked to original sources

Single-atom optical clock with high accuracy.

For the past 50 years, atomic standards based on the frequency of the cesium ground-state hyperfine transition have been the most accurate time pieces in the world. We now report a comparison between the cesium fountain standard NIST-F1, which has been evaluated with an inaccuracy of about 4 x 10(-16), and an optical frequency standard based on an ultraviolet transition in a single, laser-cooled mercury ion for which the fractional systematic frequency uncertainty was below 7.2 x 10(-17). The absolute frequency of the transition was measured versus cesium to be 1,064,721,609,899,144.94 (97) Hz, with a statistically limited total fractional uncertainty of 9.1 x 10(-16) the most accurate absolute measurement of an optical frequency to date.

Journal Article↗

Spectroscopy using quantum logic.

We present a general technique for precision spectroscopy of atoms that lack suitable transitions for efficient laser cooling, internal state preparation, and detection. In our implementation with trapped atomic ions, an auxiliary "logic" ion provides sympathetic laser cooling, state initialization, and detection for a simultaneously trapped "spectroscopy" ion. Detection is achieved by applying a mapping operation to each ion, which results in a coherent transfer of the spectroscopy ion's internal state onto the logic ion, where it is then measured with high efficiency. Experimental realization, by using 9Be+ as the logic ion and 27Al+ as the spectroscopy ion, indicates the feasibility of applying this technique to make accurate optical clocks based on single ions.

Journal Article↗

Measurement of the (199)Hg+ 5d9 6s2 (2)D(5/2) electric quadrupole moment and a constraint on the quadrupole shift.

The electric-quadrupole moment of the (199)Hg+ 5d9 6s2 (2)D(5/2) state is measured to be theta(D,5/2) = -2.29(8) x 10(-40) C m2. This value was determined by measuring the frequency of the (199)Hg+ 5d10 6s (2)S(1/2) --> 5d9 6s2 (2)D(5/2) optical clock transition for different applied electric-field gradients. An isolated, mechanically stable optical cavity provides a frequency reference for the measurement. We compare the results with theoretical calculations and discuss the implications for the accuracy of an atomic clock based upon this transition. We now expect that the frequency shift caused by the interaction of the quadrupole moment with stray electric-field gradients will not limit the accuracy of the Hg+ optical clock at the 10(-18) level.

Journal Article↗

Femtosecond-laser-based synthesis of ultrastable microwave signals from optical frequency references.

We use femtosecond laser frequency combs to convert optical frequency references to the microwave domain, where we demonstrate the synthesis of 10-GHz signals having a fractional frequency instability of < or =3.5 x 10(-15) at a 1-s averaging time, limited by the optical reference. The residual instability and phase noise of the femtosecond-laser-based frequency synthesizers are 6.5 x 10(-16) at 1 s and -98 dBc/Hz at a 1-Hz offset from the 10-GHz carrier, respectively. The timing jitter of the microwave signals is 3.3 fs.

Journal Article↗

Standards of time and frequency at the outset of the 21st century.

After 50 years of development, microwave atomic clocks based on cesium have achieved fractional uncertainties below 1 part in 10(15), a level unequaled in all of metrology. The past 5 years have seen the accelerated development of optical atomic clocks, which may enable even greater improvements in timekeeping. Time and frequency standards with various levels of performance are ubiquitous in our society, with applications in many technological fields as well as in the continued exploration of the frontiers of basic science. We review state-of-the-art atomic time and frequency standards and discuss some of their uses in science and technology.

Journal Article↗

Testing the stability of fundamental constants with the 199Hg+ single-ion optical clock.

Over a two-year duration, we have compared the frequency of the 199Hg+ 5d(10)6s (2)S(1/2)(F=0)<-->5d(9)6s(2) (2)D(5/2)(F=2) electric-quadrupole transition at 282 nm with the frequency of the ground-state hyperfine splitting in neutral 133Cs. These measurements show that any fractional time variation of the ratio nu(Cs)/nu(Hg) between the two frequencies is smaller than +/-7 x 10(-15) yr(-1) (1sigma uncertainty). According to recent atomic structure calculations, this sets an upper limit to a possible fractional time variation of g(Cs)(m(e)/m(p))alpha(6.0) at the same level.

Journal Article↗

An optical clock based on a single trapped 199Hg+ ion.

Microwave atomic clocks have been the de facto standards for precision time and frequency metrology over the past 50 years, finding widespread use in basic scientific studies, communications, and navigation. However, with its higher operating frequency, an atomic clock based on an optical transition can be much more stable. We demonstrate an all-optical atomic clock referenced to the 1.064-petahertz transition of a single trapped 199Hg+ ion. A clockwork based on a mode-locked femtosecond laser provides output pulses at a 1-gigahertz rate that are phase-coherently locked to the optical frequency. By comparison to a laser-cooled calcium optical standard, an upper limit for the fractional frequency instability of 7 x 10(-15) is measured in 1 second of averaging-a value substantially better than that of the world's best microwave atomic clocks.

Journal Article↗

Absolute frequency measurements of the Hg+ and Ca optical clock transitions with a femtosecond laser.

The frequency comb created by a femtosecond mode-locked laser and a microstructured fiber is used to phase coherently measure the frequencies of both the Hg+ and Ca optical standards with respect to the SI second. We find the transition frequencies to be f(Hg) = 1 064 721 609 899 143(10) Hz and f(Ca) = 455 986 240 494 158(26) Hz, respectively. In addition to the unprecedented precision demonstrated here, this work is the precursor to all-optical atomic clocks based on the Hg+ and Ca standards. Furthermore, when combined with previous measurements, we find no time variations of these atomic frequencies within the uncertainties of the absolute value of( partial differential f(Ca)/ partial differential t)/f(Ca) < or =8 x 10(-14) yr(-1) and the absolute value of(partial differential f(Hg)/ partial differential t)/f(Hg) < or =30 x 10(-14) yr(-1).

Journal Article↗