Quantitative microwave imaging with a 2.45-GHz planar microwave camera.

This paper presents microwave tomographic reconstructions of the complex permittivity of lossy dielectric objects immersed in water from experimental multiview near-field data obtained with a 2.45-GHz planar active microwave camera. An iterative reconstruction algorithm based on the Levenberg-Marquardt method was used to solve the nonlinear matrix equation which results when applying a moment method to the electric field integral representation. The effects of uncertainties in experimental parameters such as the exterior medium complex permittivity, the imaging system geometry and the incident field at the object location are illustrated by means of reconstructions from synthetic data. It appears that the uncertainties in the incident field have the strongest impact on the reconstructions. A receiver calibration procedure has been implemented and some ways to access to the incident field at the object location have been assessed.

Algorithms↗

Convergence and stability assessment of Newton-Kantorovich reconstruction algorithms for microwave tomography.

For newly developed iterative Newton-Kantorovitch reconstruction techniques, the quality of the final image depends on both experimental and model noise. Experimental noise is inherent to any experimental acquisition scheme, while model noise refers to the accuracy of the numerical model, used in the reconstruction process, to reproduce the experimental setup. This paper provides a systematic assessment of the major sources of experimental and model noise on the quality of the final image. This assessment is conducted from experimental data obtained with a microwave circular scanner operating at 2.33 GHz. Targets to be imaged include realistic biological structures, such as a human forearm, as well as calibrated samples for the sake of accuracy evaluation. The results provide a quantitative estimation of the effect of experimental factors, such as temperature of the immersion medium, frequency, signal-to-noise ratio, and various numerical parameters.

Algorithms↗

Microwave imaging of tissue blood content changes.

Active microwave imaging gives information on the dielectric properties of of the body, allowing the collection of data that are distinct from, but complementary to, those available from other imaging methods based on different radiations. Two types of microwave imaging systems have been developed. The first is a planar system that irradiates the object with a plane wave and collects scattered phase and amplitude data at 1024 points on a parallel plane. The data can be reconstructed using a back propagation technique to give an image of the object. The second type of system is a tomographic scanner, consisting of a multiplexed 64-element circular array of waveguides. The waveguides are electronically scanned, alternately as sources and receivers, to give a complete scan of the object with no mechanical movement. A tomographic 'slice' of the object is reconstructed using spectral domain interpolation. Both systems work at 2.45 GHz with an incident power less than 1 mW cm-2 at the object and require a coupling medium (usually water) between the object and the source/receiver. Imaging parameters are appropriate for clinical use: a spatial resolution of 1 cm, measurement time of a few seconds and contrast resolution of around 1%. The effects of changes in perfusion on images of isolated animal organs are presented. Images have also been obtained, with both systems, of the internal dielectric structure of the forearm and of variations in dielectric properties due to changes of tissue blood content effected by application and release of tourniquets to the upper arm. Results show that these changes are well demonstrated by microwave imaging, and possible clinical applications are discussed.

Animals↗

Active microwave tomographic imaging of isolated, perfused animal organs.

The relative transparency of biological materials to high-frequency electromagnetic waves has encouraged the development of new systems for imaging. This report describes experiments of microwave tomography conducted on a prototype. The object to be analyzed is submerged in water and is illuminated by a plane wave. The total electric field is analyzed by a microwave camera. The recorded data are then processed numerically in order to reconstruct the image that corresponds to the distribution of equivalent currents in a defined plane of a section. Experiments have been conducted on isolated kidneys with and without perfusion. The influence of the perfusing solution temperature has also been studied. These experiments show the potential of this system, especially through the correlation between microwave images and the biological structures. They also confirm previous results concerning spatial resolution and depth of exploration. Finally, the results demonstrate the influence of temperature and support the applicability of this imaging system in non-invasive thermometry, especially for clinical hyperthermia.

Animals↗

Microwave thermography--characteristics of waveguide applicators and signatures of thermal structures.

In this paper, we study the problem of the interpretation of the signals provided by microwave thermography, which allows the detection of the thermal gradients in living tissues. These signals correspond to the thermal noise measured by a radiometer when the probe scans the surface of the tissues (passive process). We describe how these signals can be computed by means of a new method based on the antenna reciprocity principle. This process requires a knowledge of the electrical field distribution in the lossy medium when the applicator is radiating a microwave signal (active process). Examples of computations of the thermal signals and experimental verifications are presented. Then, we introduce a new concept of 'thermal signature' and show how it is possible to reach a quantitative interpretation of the thermal signals such as those obtained in clinical investigations (thermal pattern recognition).

Microwaves↗

Electrical characteristics of waveguide applicators for medical applications.

This work concerns the electrical properties of waveguide applicators consisting of flanged rectangular waveguides filled with a dielectric, used in medical applications (microwave thermography and local hyperthermia). The reflection coefficient and the near field configuration in lossy materials were obtained in some cases analytically and in some other cases numerically. The validity of these methods was verified experimentally. The study shows that the matching of the applicator and the penetration depth in a lossy material, such as a living tissue, depend not only on the tissue characteristics but also on the characteristics of the applicator itself.