PubMed Health⌕ Search

Biomedical subjects

J C Gauthier

Publications and source records attributed to J C Gauthier.

12 recordsLinked to original sources

Complete characterization of a plasma mirror for the production of high-contrast ultraintense laser pulses.

Improving the temporal contrast of ultrashort and ultraintense laser pulses is a major technical issue for high-field experiments. This can be achieved using a so-called "plasma mirror." We present a detailed experimental and theoretical study of the plasma mirror that allows us to quantitatively assess the performances of this system. Our experimental results include time-resolved measurements of the plasma mirror reflectivity, and of the phase distortions it induces on the reflected beam. Using an antireflection coated plate as a target, an improvement of the contrast ratio by more than two orders of magnitude can be achieved with a single plasma mirror. We demonstrate that this system is very robust against changes in the pulse fluence and imperfections of the beam spatial profile, which is essential for applications.

Journal Article↗

MeV ion jets from short-pulse-laser interaction with thin foils.

Collimated jets of carbon and fluorine ions up to 5 MeV/nucleon ( approximately 100 MeV) are observed from the rear surface of thin foils irradiated with laser intensities of up to 5 x 10 (19)W/cm(2). The normally dominant proton acceleration could be surpressed by removing the hydrocarbon contaminants by resistive heating. This inhibits screening effects and permits effective energy transfer and acceleration of other ion species. The acceleration dynamics and the spatiotemporal distributions of the accelerating E fields at the rear surface of the target are inferred from the detailed spectra.

Journal Article↗

Direct observation of the ponderomotive force effects in short-scale-length laser plasmas by frequency-domain interferometry.

We report on single-shot frequency-domain interferometric measurements showing space- and time-resolved ponderomotive electron density profile steepening of a short-scale-length ultraintense laser-produced plasma. The density gradient scale length is varied by applying a time-delayed laser prepulse. The measured absolute position of the critical density surface is found to be in agreement with one-dimensional hydrodynamic simulations for the range of scale lengths studied.

Journal Article↗

Non-thermal melting in semiconductors measured at femtosecond resolution.

Ultrafast time-resolved optical spectroscopy has revealed new classes of physical, chemical and biological reactions, in which directed, deterministic motions of atoms have a key role. This contrasts with the random, diffusive motion of atoms across activation barriers that typically determines kinetic rates on slower timescales. An example of these new processes is the ultrafast melting of semiconductors, which is believed to arise from a strong modification of the inter-atomic forces owing to laser-induced promotion of a large fraction (10% or more) of the valence electrons to the conduction band. The atoms immediately begin to move and rapidly gain sufficient kinetic energy to induce melting--much faster than the several picoseconds required to convert the electronic energy into thermal motions. Here we present measurements of the characteristic melting time of InSb with a recently developed technique of ultrafast time-resolved X-ray diffraction that, in contrast to optical spectroscopy, provides a direct probe of the changing atomic structure. The data establish unambiguously a loss of long-range order up to 900 A inside the crystal, with time constants as short as 350 femtoseconds. This ability to obtain the quantitative structural characterization of non-thermal processes should find widespread application in the study of ultrafast dynamics in other physical, chemical and biological systems.

Journal Article↗

Study of the ion-distribution dynamics of an aluminum laser-produced plasma with picosecond resolution.

The ion-distribution dynamics of an expanding aluminum plasma produced by a nanosecond laser pulse at moderate intensity (10(13) W cm(-2)) is studied by point-projection x-ray absorption spectroscopy with unprecedented, picosecond, time resolution. We show that the ionic populations measured as a function of distance to the target and at different probing times differ markedly from those predicted by widely accepted collisional radiative models coupled to hydrodynamic simulations. We discuss the effects of radiation, conduction, and expansion cooling on the spatiotemporal ionic distribution evolution.

Journal Article↗

Comparison of measured and calculated X-ray and hot-electron production in short-pulse laser-solid interactions at moderate intensities.

Ultrashort pulse laser-solid interaction experiments with 4x10(16) W/cm(2),120 fs, 45 degrees incidence angle, p-polarized pulses are theoretically analyzed with the help of 1(1/2)-dimensional (1(1/2) D) particle-in-cell (PIC) simulations. The laser impinges upon preformed plasmas with a precisely controlled density-gradient scale-length. PIC electron distribution functions are used as an input to 3D Monte Carlo simulations to interpret measured electron distributions and Kalpha radiation emission. Satisfactory agreement between the experimental and simulation results is obtained for the measured absorption coefficient, the energy distribution of the back-scattered hot electrons, the hot-electron temperature in the bulk of the target, and the Kalpha yield, when the preplasma scale-length is varied.

Journal Article↗

Hot-electron distribution functions in a subpicosecond laser interaction with solid targets of varying initial gradient scale lengths.

We have studied the distribution function of the hot electrons produced during the interaction of a 120-fs, 60-mJ, 800-nm wavelength and a p-polarized laser pulse with bilayered Al/Fe targets. The main pulse interacts with a preformed plasma, obtained with a controlled prepulse, whose density gradient scale length has been measured. The electron distribution function is characterized by means of the Kalpha emission of the two materials of the target as a function of the Al-layer thickness. The low-energy region (<50 keV) of the hot-electron distribution function shows no dependency in shape on the gradient scale length, but only a variation in the total number of the generated electrons. The comparison between the experimental results and the particle-in-cell and Monte Carlo calculations of the electron distribution function and the Kalpha emission is gratifying.

Journal Article↗

Children's self-report of postoperative pain intensity and treatment threshold: determining the adequacy of medication.

OBJECTIVE: Many studies have shown indirectly that children are undermedicated for postoperative pain. In this study, we used a pain self-report scale to examine this more directly. METHODS: We performed a survey with 63 children who were postoperative from minor, uncomplicated surgery. Using the self-report scale, we determined the pain intensity at time of interview, the worst pain experienced postoperatively, and the intensity of pain that the subject felt to warrant pharmacologic intervention (the "treatment threshold"). A subgroup of 48 children was asked to indicate on the scale the intensities that represented mild, moderate, and severe pain. RESULTS: Mean (SD) pain at time of interview was 1.9 (1.7) on the 0-6 scale. Mean worst postoperative pain was 3.8 (1.8). The mean for treatment threshold was 3.2 (1.8). We found gender differences in regard to the judgments about the intensities representing mild, moderate, and severe pain, with girls rating these lower than did boys. Twenty-five percent of subjects reported pain that was mild, 29% reported moderate pain, and 46% reported severe pain. CONCLUSIONS: We found that 51% of subjects were undermedicated for postoperative pain, being required to suffer pain that was above their treatment threshold. By determining each subject's treatment threshold and estimate of moderate pain, we have better defined the intensity at which pain becomes clinically significant.

Adolescent↗

Metabolic activation of the nitroaromatic antiandrogen flutamide by rat and human cytochromes P-450, including forms belonging to the 3A and 1A subfamilies.

The in vitro metabolic activation of flutamide, a nitroaromatic antiandrogen which produces hepatitis in a few recipients, was first studied with male rat liver microsomes. There was no electron spin resonance evidence for the reduction of flutamide by reduced nicotinamide adenine dinucleotide phosphate (NADPH)-cytochrome P-450 reductase into a nitro anion free radical. In contrast, flutamide was oxidatively transformed by cytochrome P-450 into reactive metabolite(s) that covalently bound to microsomal proteins. Covalent binding required oxygen and NADPH, and was decreased by the nucleophile glutathione and by the cytochrome P-450 inhibitors SKF 525-A, piperonyl butoxide and troleandomycin (an inhibitor of the cytochrome P-450 3A subfamily). Covalent binding was increased markedly by pretreatment with dexamethasone (an inducer of the cytochrome P-450 3A subfamily) and moderately by pretreatment with beta-naphthoflavone (an inducer of the 1A family). Covalent binding was immunoinhibited markedly by anticytochrome P-450 3A immunoglobulin G and moderately by anticytochrome P-450 1A immunoglobulin G. Covalent binding was much lower with liver microsomes from female rats (not expressing P-450 3A2). Covalent binding of flutamide also occurred with human liver microsomes (where it was inhibited by troleandomycin), and with yeast microsomes expressing human liver cytochromes P-450 1A1, 1A2 or 3A4. We concluded that flutamide was oxidatively transformed into chemically reactive metabolite(s) by rat and human cytochromes P-450, including forms belonging to the 3A and 1A subfamilies.

Animals↗

Rat adult hepatocytes in primary pure and mixed monolayer culture. Comparison of the maintenance of mixed function oxidase and conjugation pathways of drug metabolism.

The stabilities of several drug oxidation and conjugation pathways in adult rat hepatocytes were investigated in two systems: a primary pure culture lasting 3 days and a primary mixed culture (hepatocytes co-cultured with epithelial cells) lasting 10 days. The cytochrome P450 content in hepatocytes drastically declined within 48 hr in both culture systems. Cytochrome P450-dependent mixed function oxidase was measured by the O-dealkylation of ethoxyresorufin (EROD) and of pentoxyresorufin (PROD). UPD-glucuronosyl transferase (UDP-GT) activity was measured using 1-naphthol and morphine as substrates. In both culture systems, the activities of enzymes belonging to the 3-methylcholanthrene-inducible family, namely EROD and 1-naphthol UDP-GT, were much better maintained than those of PROD and morphine UDP-GT, which belong to the phenobarbitone-inducible family: in pure cultures, EROD and 1-naphthol UDP-GT activities declined to 60% of initial values within 3 days; in mixed cultures, EROD activity was stable throughout the 10 day culture period, whereas that of 1-naphthol UDP-GT was stable until day 4 but had declined to 70% of the initial value by day 8. In contrast, PROD and morphine UDP-GT activities declined to approx. 30% of the initial values within 2 days in both culture systems, and had dropped to approx. 10% of the initial value within 8 days in mixed culture. Reduced glutathione (GSH) levels fluctuated, but remained high throughout culture. GSH conjugation declined to 40% of initial values within 3 days in pure culture, whereas it remained relatively constant in mixed culture. Comparison of these two culture systems therefore showed that although the inclusion of epithelial cells did prolong hepatocyte viability, there was a change in relative enzyme activities in both systems, suggesting a shift towards a more de-differentiated drug metabolism pattern.

Animals↗