PubMed Health⌕ Search

Biomedical subjects

J C Goh

Publications and source records attributed to J C Goh.

46 records · Page 3Linked to original sources

Principles and applications of Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) technology in orthopaedics.

The principles involved in Computer-Aided Design (CAD) and Computer-Aided Manufacturing (CAM) technology is presented in this article. It also highlights the current advances and capability of this technology. Application of the CAD/CAM technology in orthopaedics is relatively new. Three broad areas of applications can be defined: (1) three-dimensional reconstructions of skeletal structure based on any of the imaging technique, i.e. CT scan, MRI or X-ray, to analyse, simulate, design and evaluate orthopaedic procedures without having to actually perform the surgery; (2) the production of plastic or wax models for surgeons to have global impressions and understanding of complex cases of bone and joint disorders and the possibility of using the physical models as templates to sculpt allograft pre-operatively; and (3) to design and manufacture geometrically optimal standard and customised implants. CAD/CAM technology is also rapidly developing in the field of prosthetics, orthotics and orthopaedics footwear. The advantages offered include shorter delivery time, more consistent design, quantifiable rectification and "modern" or remote manufacturing. Apart from these applied usage, the CAD/CAM technology is also an effective tool for education and training. The application of CAD/CAM technology in orthopaedics and its related fields has been shown to have tremendous potential, but may appear to be too esoteric, complex and costly at the present moment. However, with improved generality, simplicity and cost-effectiveness of the system, it will become more practical.

Computer Simulation↗

Postnatal development of the Sertoli cell barrier, tubular lumen, and cytoskeleton of Sertoli and myoid cells in the rat, and their relationship to tubular fluid secretion and flow.

The postnatal development of the Sertoli cell barrier, tubular lumen, fluid flow, and cytoskeletal elements in Sertoli and myoid cells was investigated in the Sprague-Dawley rat. With the aid of hypertonic fixatives, a barrier to the rapid entry of fluid was noted in the majority of tubules on the 15th and 16th postnatal (p.n.) days and was completely formed in all tubules prior to p.n. day 18. The actin forming the ectoplasmic specialization (ES), a cytoskeletal complex related to the occluding junctions composing the barrier, began its development during the period of initial barrier formation (16 p.n. day) and progressively attained its adult prominence. The ES developed its characteristic adult pattern and adult fluorescent intensity at about p.n. day 22. Some seminiferous tubules showed very small lumina as early as p.n. day 10. All tubules were not open until p.n. day 30. The size (diameter) of the lumen increased slowly from p.n. day 10 until p.n. day 30 when it started to increase rapidly until about p.n. day 50. Fluid flow in seminiferous tubules was detected as early as p.n. day 20 and increased in amount thereafter. Myoid cell actin filament bundles, running in parallel, were present at p.n. day 10. Actin formed a meshwork pattern characteristic of the adult on, or slightly prior to, p.n. day 22. These data indicate that there is a temporal relationship between the development of the actin cytoskeleton within the Sertoli cell and initial formation of the Sertoli cell barrier. Similarly, there is a temporal relationship between the development of the actin cytoskeleton of myoid cells and tubular fluid flow. The rapid increase in tubular lumen diameter, however, does not correlate with the initial development of Sertoli and myoid cytoskeletal elements.

Actin Cytoskeleton↗

Effect of preservation medium on the mechanical properties of cat bones.

Mechanical properties of long cat bones after freezing at -20 degrees C and after storage in 10 percent buffered formalin were investigated. The right humeri and femora from 48 adult cats were divided into four groups: Groups 1 and 2 were stored in a freezer at -20 degrees C for 3 and 21 days, respectively, while Groups 3 and 4 were stored in 10 percent buffered formalin for 3 and 21 days, respectively. The control left bones were tested fresh. The humeri were subjected to a torsion test and the femora to a four-point bending test. Freezing had no effect on the mechanical properties evaluated, while formalin storage caused a 50 percent reduction in energy absorption and increased the brittleness of the bones.

Animals↗

Biofeedback device for patients on axillary crutches.

The axillary crutch is commonly prescribed as an ambulatory aid to patients with temporal or permanent disability in the lower extremity. When fitting the axillary crutch, it is important that the user be instructed not to bear excessive weight on the axillary bar. Excessive weight bearing on the axillary bar can result in a sevenfold increase in the reaction force under the armpit. This force may be a contributory factor to crutch paralysis or thrombosis of the axillobrachial artery. In order to prevent this occurrence an electronic biofeedback device was designed and developed for use in the training of 3-point swing-through axillary crutch ambulation. It detects excessive weight bearing on the axillary bar during crutch ambulation and produces an audible signal which prompts the patient to make necessary adjustment to relieve load bearing on the axillary bar. The design and development of the biofeedback device is discussed in this paper.

Biofeedback, Psychology↗

The consequences of actin disruption at Sertoli ectoplasmic specialization sites facing spermatids after in vivo exposure of rat testis to cytochalasin D.

Cytochalasin D (CD) was used to perturb actin filaments of the Sertoli ectoplasmic specialization (ES)--a cytoskeletal complex of the Sertoli cell related to spermatids. CD (500 microM for 6 h) produced a loss of 88% of the ES facing the head region of early (Step 8) elongating spermatids as compared to vehicle (dimethylsulfoxide:saline) controls. Nitrobenzoxadiazole-phallacidin staining of F-actin revealed a CD-related loss of uniform fluorescence over the head of elongated spermatids. To examine for a possible relationship between the presence of actin and cell attachment at ES sites, hypertonic fixatives were introduced to provoke cell shrinkage and stress ES-associated junctions. After osmotic stress, cell-to-cell adhesion at ES sites remained intact in vehicle-treated animals. CD treatment caused Sertoli cells to separate from elongating spermatids at sites where ES had been lost from the Sertoli cell surface. It is suggested that actin of the ES plays a role in cell-to-cell interaction analogous to its possible role at the Sertoli cell barrier. In CD-treated animals, structures resembling tubulobulbar complexes frequently developed at sites where ES was lost, suggesting that the loss of ES has a facilitatory role in tubulobulbar complex formation. It is hypothesized that tubulobulbar complexes are devices that rid the cells of ES-associated junctional links to effect dissociation of the spermatid from the Sertoli cell during spermiation. Spermatids at Step 8 of development are known to become oriented with their acrosomes facing the base of the Sertoli cell. After CD treatment, a 5.8-fold increase in malorientation of Step 8 spermatids was noted. A role for the ES cytoskeletal complex in orienting the spermatid acrosome toward the basal aspect of the Sertoli cell is also suggested.

Actins↗

Effects of electrical stimulation on the biomechanical properties of fracture healing in rabbits.

One hundred fifteen white rabbits with an average weight of 2.0 kg were used to study the influence of electrical stimulation on osteogenesis. They were divided into three groups: Group I was electrically stimulated with a constant direct current of 20 microamperes delivered to the fracture site; Group II was the control group having the same protocol as Group I except that the stimulator was not switched on; and Group III was the normal fracture healing group (no introduction of electrodes to the fracture site). Roentgenologic and histologic assessment showed that new bone formation in the electrical stimulation group was more exuberant than those in the other two groups in observation periods from three to eight weeks. However, at 12 weeks no difference was observed among the three groups. Biomechanical analysis showed definite increases in the breaking strength and bending stiffness of the fracture healing tibia in Group I, especially at six weeks after surgery. However, at 12 weeks no significant difference was observed among the three groups. Therefore, electrical stimulation of fracture healing has a positive effect only at the midphase of the healing process, and it does not lead to faster fracture healing.

Animals↗

Biomechanical study on axillary crutches during single-leg swing-through gait.

This paper describes a kinetic and kinematic study on axillary crutches during one-leg swing-through gait. The primary objective is to evaluate the interplay of forces at the crutch and body interfaces and to relate them in the understanding of problems associated with the use of axillary crutches. Ten normal adult male subjects with simulated left leg impairment participated in the study. For data acquisition, the VICON kinematic system, a Kistler force plate and an instrumented crutch (with force transducers at the two upper struts close to the axillary bar and one near the crutch tip) were used. Results showed that the peak ground reaction force on the weight-bearing leg during lower limb stance increased by 21.6 percent bodyweight. The peak reaction force transmitted to the arm during crutch stance was 44.4 percent bodyweight. These increased loadings could be detrimental to patients with unsound weight-bearing leg and upper extremities respectively. When the crutches were used incorrectly, 34 percent bodyweight was carried by the underarm. This could cause undue pressure over the neurovascular structures at the axillary region.

Adult↗

Surface morphology of Asian cadaveric hips.

The joint surfaces of 60 hips obtained from the cadavers of elderly Asians were studied to determine the incidence, the grade and the distribution of both non-progressive (age-related) and progressive degenerative changes. It was observed that in the Asian population of 40 to 90 years of age, non-progressive changes were common, being seen in 66% of the acetabular specimens and 50% of the femoral heads. Only one specimen of the 60 showed unexplained progressive degenerative change. We conclude that primary osteoarthritis of the hip is rare in Asians.

Acetabulum↗

Biomechanical evaluation of SACH and uniaxial feet.

A review of prosthetic prescription practice reveals that in the United Kingdom about 85% of below and above-knee amputees are fitted with uniaxial feet, whereas in the United States about 80% are fitted with SACH feet. An evaluation method was developed to assess the performance of these two different types of feet. This included a subjective assessment procedure and a biomechanical evaluation of the function of the two feet and their effects on whole body gait kinematics and lower limb kinetics. Data were acquired by three Bolex H16 cine cameras and two Kistler force plates. This set-up allowed three-dimensional analysis on the prosthetic and contralateral sides of the subject. Investigations were undertaken in which an experimental prosthesis permitted the interchange of the ankle/foot while keeping the rest of the components the same. Altogether, six below knee and five above knee amputees were tested. No clear trend for preference for either type of foot was evident from the subjective survey; in general the patients showed a preference for the foot that they were accustomed to. Kinematic and kinetic analysis showed some differences in the function between the two prosthetic feet. It is the purpose of this paper to discuss these differences and their significance.

Ankle Joint↗