Development of an integrated CAD-FEA process for below-knee prosthetic sockets.

BACKGROUND: Computer-aided design and manufacturing has been successfully used in prosthetic applications since 1980s. It simplifies the socket rectification process and improves reproducibility but does not introduce any new principle into socket design. Integrating finite element analysis to CAD will provide a more objective assessment of socket fit and improve the chance of a successful first fitting. METHODS: Current study aims to establish a finite element model generation technique directly from geometrical information of commercial prosthetic CAD workstation. A program developed in-house automatically performs meshing of the stump geometry and assigns suitable material properties, load and boundary conditions to the model. The model was validated by comparing predicted pressure with experimentally measured values for one amputee subject. FINDINGS: The predicted pressure distribution has an root-mean-square error of 8.8 kPa compared to experimental values at 10%, 25% and 50% of the gait cycle. INTERPRETATION: Current method was able to develop a finite element model to predict interface pressure reasonably well and can be integrated with prosthetic CAD system to provide quantitative feedback to the prosthetist in an automated process.

Artificial Limbs↗

Measurement of the visual contribution to postural steadiness from the COP movement: methodology and reliability.

We studied the reliability of different measures of the visual contribution to postural steadiness by recording the postural sway during standing with eyes open (EO) or eyes closed (EC). The COP trajectory was recorded in 21 subjects aged 42-61 standing on a firm or foam support. The improvement of postural steadiness due to vision was measured with a higher reliability (i.e. lower intra- and inter-subject variabilities) with the sway velocity V, than with the position RMS. Due to the increase of the variability of V and RMS with their own mean values, we quantified the visual contribution to posture by the stabilization ratio (SR), based on a logarithm transform of V or RMS. As compared to the Romberg quotient (EC/EO), SR improved the reliability of the measurement of the visual contribution to posture within individuals, across subjects, and even across different studies in the literature. Our method led to decrease the inter-subject coefficient of variation of this measurement to about 25%, using a foam support. It leads to a similar accuracy in binocular and monocular vision, and it also applies to the quantification of other non-visual sensory contributions to posture.

Adult↗

Characterization of knitted polymeric scaffolds for potential use in ligament tissue engineering.

Different scaffolds have been designed for ligament tissue engineering. Knitted scaffolds of poly-L-lactic acid (PLLA) yarns and co-polymeric yarns of PLLA and poly(glycolic acid) (PLGA) were characterized in the current study. The knitted scaffolds were immersed in medium for 20 weeks, before mass loss, molecular weight, pH value change in medium were tested; changes in mechanical properties were evaluated at different time points. Results showed that the knitted scaffolds had 44% porosity. There was no significant pH value change during degradation, while there was obvious mass loss at initial 4 week, as well as smooth molecular weight drop of PLLA. PLGA degraded more quickly, while PLLA kept its integrity for at least 20 weeks. Young's modulus increased while tensile strength and strain at break decreased with degradation time; however, all of them could maintain the basic requirements for ACL reconstruction. It showed that the knitted polymeric structures could serve as potential scaffolds for tissue-engineered ligaments.

Biodegradation, Environmental↗

Mesenchymal stem cells in musculoskeletal tissue engineering: a review of recent advances in National University of Singapore.

A key factor in the tissue engineering approach to tissue repair and regeneration is the use of appropriate cells. Mesenchymal stem cells (MSCs) are derived from bone marrow stroma or connective tissues and they have the potential to differentiate into various mesenchymal cell lines in vitro and in vivo. These cells hold great promise for musculoskeletal tissue engineering. This review is based mainly on the work which has been done in the National University of Singapore on the use of MSCs for engineering cartilage, growth plate, bone and tendon/ligament as well as the clinical trail of autologous chondrocyte implantation. It can help to shape future research on musculoskeletal tissue engineering.

Animals↗

Biomechanical strength of deep-frozen versus lyophilized large cortical allografts.

OBJECTIVE: To compare biomechanical strength of deep-frozen versus lyophilized large cortical allografts. DESIGN: In vivo transplantation studies performed in tibia of adult cats using 4 cm deep-frozen and lyophilized, gamma-irradiated allografts to bridge large cortical defect model. BACKGROUND: Bridging large cortical bone defect is a challenging problem. Options include autografts, allografts, bioceramics and prostheses. Allografts provide a suitable option. METHODS: Forty mature cats were used. A large defect (4 cm) was created in mid-diaphysis of right tibia. In 16 cats, cortical defect was reconstructed using deep-frozen allografts (-80 degrees C) with intra-medullary rodding. In another 16 cats, lyophilized, gamma-irradiated allografts were used. Observation periods include 8, 12, 16 and 24 weeks. The specimens were procured together with unoperated legs as controls. Mechanical testing was performed using a materials testing machine with torsion test device of up to 500 Nm at speed of 0.18 rpm. Parameters studied included maximum torque, torsional stiffness and energy of absorption. RESULTS: Deep-frozen allografts did not reach 100% strength, achieving only 64% at 6 months. In marked contrast, lyophilized allografts were significantly weaker with only 12% maximum torque strength at 6 months. Lyophilized allografts were significantly weaker than deep-frozen allografts in all observation periods (p < 0.05). CONCLUSION: Deep-frozen allografts did not reach 100% normal strength and were significantly weaker than non-vascularised autografts. Lyophilized allografts were significantly weaker than deep-frozen allografts. RELEVANCE: For the reconstruction of massive cortical bone defects, only deep-frozen cortical allografts should be used. Lyophilized allografts are not suitable.

Animals↗

Stump/socket pressure profiles of the pressure cast prosthetic socket.

OBJECTIVE: The aim was to evaluate stump/socket interface pressure in amputees wearing a socket developed by a pressure casting system.Design. Five unilateral transtibial amputees wore a pressure cast socket and walked at a self-selected speed. BACKGROUND: The socket produces equally distributed pressure at the stump/socket interface, deviating from the conventional belief that pressure varies in proportion to the pain threshold of different tissues in the stump. METHODS: The socket was fabricated while the subject placed his stump in a pressure chamber. Pressure was applied while he adopted a normal standing position. A specially built strain gauged type pressure transducer was used for measuring pressure distribution. Pressure and gait parameters were measured simultaneously while the subjects were standing and walking. RESULTS AND CONCLUSION: The pressure cast technique was able to provide comfortable fitting sockets. A hydrostatic pressure profile was not evident during standing or gait. Results also showed that no standard pressure profile for the pressure cast socket was observed. This was expected as no rectifications were done on the pressure cast socket. Pressure profiles at 10%, 25% and 50% of gait cycle did not correlate with the pressure profiles previously proposed. RELEVANCE: The hydrostatic theory is an attractive concept in socket design as it produces a stump/socket pressure profile that is evenly distributed. Furthermore, it is a method that is easily implemented, independent of a prosthetist's skill and experience and reduces manufacturing time. However, there is still controversy surrounding the efficacy of this hydrostatic theory.

Adult↗

Static and dynamic pressure profiles of a patellar-tendon-bearing (PTB) socket.

The purpose of this study was to evaluate the pressure distribution at the stump/socket interface in amputees wearing the patellar-tendon-bearing socket. A specially built strain gauged type pressure transducer was used for measuring this pressure distribution in four unilateral transtibial amputees. Pressure and gait parameters were measured simultaneously while they were standing and walking. Pressure profiles were compiled at 10, 25 and 50 per cent of gait cycle and compared with the pressure profiles predicted by Radcliffe in 1961. The subject's anterior-posterior pressure profiles were different from each other. However, at toe-off, each subject exhibited an increase in pressure at the patellar tendon. Their medial-lateral pressure profiles were similar: exhibiting high pressure at the medial proximal and lateral distal regions except for one subject who exhibited high pressure at the lateral proximal region instead. The subjects' pressure profiles did not resemble Radcliffe's anticipated pressure profiles. This was because ground reaction force was not the only factor affecting the resulting pressure profiles.

Adult↗

In vivo mesenchymal cell recruitment by a scaffold loaded with transforming growth factor beta1 and the potential for in situ chondrogenesis.

The objectives of this study were (1) to develop a biphasic implant made of a bioresorbable polymeric scaffold in combination with TGF-beta1-loaded fibrin glue for tissue-engineering applications, and (2) to determine whether the implant made of a polycaprolactone (PCL) scaffold and TGF-beta1-loaded fibrin glue could recruit mesenchymal cells and induce the process of cartilage formation when implanted in ectopic sites. Twenty-four 6-month-old New Zealand White rabbits were used. Scaffolds loaded with various doses of TGF-beta1 in fibrin glue were implanted subcutaneously, intramuscularly, and subperiosteally. The rabbits were killed and implants were removed at 2, 4, and 6 weeks postoperatively. The specimens were subjected to various staining techniques for histological analysis. Light microscopic examination of all specimens revealed that the entire pore space of the scaffolds was filled with various tissues in each group. The entire volume of the scaffolds in the groups loaded with TGF-beta1 and implanted intramuscularly and subcutaneously was populated with mesenchymal cells surrounded with an abundant extracellular matrix and blood vessels. The scaffold loaded with TGF-beta1 and implanted subperiosteally was found to be richly populated with chondrocytes at 2 and 4 weeks and immature bone formation was identified at 6 weeks. We conclude that scaffolds loaded with TGF-beta1 can successfully recruit mesenchymal cells and that chondrogenesis occurred when this construct was implanted subperiosteally.

Animals↗

Structural integrity of polypropylene prosthetic sockets manufactured using the polymer deposition technique.

Rapid prototyping (RP) technology has been used recently as a means for automated socket fabrication. Although the technology has proven to be promising and has truly automated the socket fabrication process, the structural integrity of RP sockets remains questionable. For the long term, unsupervised use of these 'unconventional' sockets, their material properties and structural integrity must be determined. This study investigated the structural integrity of polypropylene sockets manufactured using a polymer deposition technique, in which a socket is formed by a continuous strand of partially melted polypropylene that is spirally deposited according to the socket's cross-sectional contour. To investigate the problem of delamination of the socket, the tensile properties of the socket material were determined according to ASTM D638-99. The ultimate tensile strength was found to be approximately 13-23 per cent lower than that of polypropylene sheets that are at present normally used for socket fabrication. In order to improve the load-bearing capacity of the socket, it was reinforced using a double-wall arrangement at the distal region, where failure normally occurs. The structural integrity of the complete prosthesis was then investigated according to ISO 10328 (loading condition II). The prosthesis passed the static loading test registering only 12 mm permanent deformation, and it successfully completed a preliminary cyclic test of 250,000 cycles with no observable failure.

Computer-Aided Design↗

Biomechanical study on femoral neck fracture fixation in relation to bone mineral density.

Twenty pairs of fresh-frozen cadaveric femurs were used in the study. The left femurs were used as control for the mechanical testings and bone mineral content scans, the right femurs were divided into two experimental groups, i.e. 'fractured' group and 'healed' group. In the 'fractured' group, twelve right femurs were osteotomized at the plane perpendicular to the femoral neck shaft axis, through the mid-cervical area of the femoral neck. The artificially created fractures were fixed with the AO dynamic hip screw system using a 4-hole plate and a compression screw. In the 'healed' group, the dynamic hip screws were applied to eight intact right femurs to simulate healed fractures. Bone mineral density scans and mechanical testings were performed on all the femurs. Good correlation was observed between bone mineral density and femoral neck strength in the control group. There was a decrease of 43.5% in strength in the 'fractured' group when compared to the control group. However, in the 'healed' group the failure load was found to be 15.2% lower than the control group. The femoral fixation strength in the 'fractured' and 'healed' groups had good correlation with the bone mineral density. RELEVANCE--:Results from this study indicated that bone mineral density is an important predictive factor in fracture fixation failure. Therefore it may be appropriate to consider the bone mineral density of a patient with proximal femoral fracture treated with fixation devices, as a criterion in prescribing a more protective postoperative management, with respect to weight bearing protocol.

Journal Article↗