PubMed Health⌕ Search

Biomedical subjects

J C Hoffman

Publications and source records attributed to J C Hoffman.

At least 109 records · Page 6Linked to original sources

Diagnosis of cerebral metastases: double-dose delayed CT vs contrast-enhanced MR imaging.

For patients suspected of having cerebral metastases, double-dose delayed CT (DDD-CT) has proved significantly more sensitive than CT scans obtained immediately after administration of a lesser dose of iodinated contrast material. Previous reports confirm the advantages of postcontrast MR imaging over contrast-enhanced CT, but data comparing DDD-CT and contrast-enhanced MR have not been reported. This study describes comparative imaging results in 23 patients who had contrast-enhanced MR imaging to clarify equivocal findings on DDD-CT studies. Contrast-enhanced MR demonstrated more than 67 definite or typical parenchymal metastases. T2-weighted MR revealed more than 40, while DDD-CT revealed only 37 typical metastatic lesions. Three patients had five or fewer lesions on DDD-CT and lesions "too numerous to count" on MR. The frequency of equivocal or unconvincing lesions was similar on DDD-CT (11) and contrast-enhanced MR (10). On T2-weighted images, we noted a substantially higher number of equivocal lesions (19), fewer definite metastases, and a number of definite metastases that had no corresponding lesion on the enhanced studies, confirming the inability of T2-weighted imaging to specifically identify cerebral metastases. In one case, multiple tiny lesions on T2-weighted images were not apparent on DDD-CT scans and were recognized only in retrospect on contrast-enhanced MR images. In this series, MR with enhancement proved superior to DDD-CT for lesion detection, anatomic localization of lesions, and differentiation of solitary vs multiple lesions. Cost-benefit considerations precluded a comparison between the two techniques in all patients suspected of having cerebral metastases.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Gadopentetate dimeglumine-enhanced MR imaging in children following surgery for brain tumor: spectrum of meningeal findings.

Gadopentetate dimeglumine-enhanced MR imaging was performed in 51 consecutive postoperative pediatric neurosurgical patients with a diagnosis of brain tumor. These studies were examined retrospectively to determine the spectrum of meningeal findings in this patient population. Patterns of enhancement were correlated with type of surgery, interval since surgery, clinical and CSF findings, and the use of radiation and steroid therapies. Normal postoperative meningeal findings include no meningeal enhancement or mild focal or diffuse dural enhancement. More moderate dural or subdural enhancement may be seen in clinically well children who have postsurgical subdural collections, or who have a remote history of serious meningeal disease (meningitis or subarachnoid hemorrhage). In all six cases in which nodular dural, leptomeningeal, or ependymal enhancement was seen, recurrent local tumor, leptomeningeal metastases, or infection were present. Leptomeningeal tumor or infection should be suspected if such patterns of enhancement are noted. Parameters that did not appear to affect the pattern of meningeal enhancement included type of surgery, interval since surgery, or therapeutic radiation.

Adolescent↗

MR measurement of intracranial CSF volume in 41 elderly normal volunteers.

A noninvasive nonplanimetric MR protocol was used to measure the total intracranial CSF volume in 41 normal subjects, aged 60-84 years, who were intensively screened to eliminate CNS disease. The protocol entailed application of MR imaging data acquired with a spin-echo sequence in a single thick slice encompassing the head. The results show a strong correlation between increased intracranial CSF volume and increasing age, and a weaker correlation between increased intracranial CSF volume and increasing total intracranial volume. The possibility of employing a CSF volume measurement as a reflection of brain atrophy to help diagnose dementia is discussed.

Aged↗

Intracranial ganglioglioma: MR, CT, and clinical findings in 18 patients.

Eighteen cases of pathologically proved intracranial gangliogliomas were reviewed to determine their MR, CT, and clinical characteristics. Seventeen patients were evaluated with contrast-enhanced CT and 14 were studied by MR imaging. Eight tumors were predominantly cystic; half of these demonstrated some contrast enhancement, and five contained calcifications. These cystic gangliogliomas were located, in order of decreasing frequency, in the cerebellum, temporal, frontal, and parietal lobes. Ten tumors were solid; eight of these showed contrast enhancement, and only one contained calcifications. Small cysts were present in one solid mass. Solid gangliogliomas occurred preferentially in the temporal lobes. On MR, the findings were nonspecific and reflected the CT findings. In one patient who received gadolinium-DTPA the lesion did not enhance. Clinically, all patients presented with nonfocal long-standing symptoms and all but three were alive an average of 18 months after the initial diagnosis. Pathologists are recognizing ganglioglioma with increasing frequency, and although its radiographic characteristics vary, it should be included in the differential diagnosis when the above-described findings are encountered.

Adolescent↗

Primary cerebral neuroblastoma: CT and MR findings in 12 cases.

A retrospective CT, MR, and clinical study was performed in 12 patients, five children and seven adults, with histologically proved primary CNS neuroblastoma. The CT and MR appearances of these neoplasia were more variable than generally recognized. Although seven tumors were predominantly intraparenchymal masses with calcification and cyst formation, five were intra- or juxtaventricular. CT was preferable to noncontrast MR both at initial diagnosis and follow-up for identification of calcification, recurrent tumor at surgical sites, and leptomeningeal disease. Noncontrast MR was useful primarily for localization of peri- and intraventricular lesions. We conclude that primary CNS neuroblastoma has a more variable radiographic appearance than is generally recognized, and that an intra- or periventricular epicenter is common.

Adult↗

The bright intervertebral disk: an indirect sign of abnormal spinal bone marrow on T1-weighted MR images.

Two phantoms were constructed and imaged for the purpose of reproducing and understanding the relatively increased signal intensity of intervertebral disks on T1-weighted MR images in three patients with diffuse vertebral metastases. The first phantom simulated a normal spine and showed that the disks and vertebral bodies were of similar intensity. The second phantom simulated an abnormal spine and showed that the disks were brighter than the vertebrae. Prolonged relaxation times from the vertebral bodies as well as manipulation of the window width and level are the factors responsible for the presence of bright disks on T1-weighted images. Variations in the window width and level can accentuate the apparent increase in signal intensity from the disks but not reverse it. Although the presence of bright disks may be subtle, recognition of this sign should raise the possibility of diffuse replacement of normal fatty bone marrow in the vertebrae.

Aged↗

Duplex Doppler sonography of the carotid artery: false-positive results in an artery contralateral to an artery with marked stenosis.

Anecdotal reports have described a false-positive "jet effect" or velocity increase in the carotid artery contralateral to an artery with significant stenosis or occlusion when using duplex Doppler sonography. In this study, the frequency, significance, and possible reasons for this finding were evaluated by a retrospective comparison of duplex sonography and angiography. Twenty-three patients with unilateral 81-100% carotid artery stenosis who underwent both duplex sonography (16 Acuson, seven Quantum) and angiography were evaluated. In 14 patients, there was an accurate or slight underestimate (less than 20%) of stenosis present in the internal carotid artery contralateral to an artery with tight stenosis/occlusion. In nine, a velocity increase in the internal carotid artery resulted in overestimation (10-80%) of the actual degree of stenosis. In one of these nine patients, real-time images were sufficient to explain the velocity increase on the basis of vessel tortuosity. In one, falsely elevated velocity resulted from inaccurate assignment of the Doppler angle of incidence in a patient in whom real-time visualization of a distal internal carotid lesion was poor. In four of the nine patients, cross filling via the circle of Willis toward the side of greater stenosis occurred. However, seven of 14 patients in whom there was duplex sonography/angiography agreement or slight duplex sonography underestimation also had cross filling. Vertebral artery patency did not correlate well with the presence of a "jet effect."(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

CT-surgical correlation in pituitary adenomas: evaluation in 113 patients.

A retrospective study was undertaken in 113 patients with surgically proven pituitary adenomas to correlate the frequency, type, and location of computed tomographic (CT) abnormalities with surgical findings. There were 63 prolactin-secreting, 19 growth-hormone-secreting, 12 adrenocorticotropic-hormone-secreting, two thyroid-stimulating-hormone-secreting, and 17 nonfunctioning adenomas. The 51 functioning and nonfunctioning macroadenomas had similar CT appearances. Only 34 secretory adenomas presented as discrete, focal, hypodense lesions; the rest were isodense with the adjacent pituitary gland. Secretory adenomas were clinically apparent earlier, and accordingly the abnormalities seen on CT were less developed. The location of the normal pituitary gland could not be determined by attenuation characteristics; only by infundibulum displacement or opposite to a discrete, focal, hypodense lesion could the gland location be predicted reliably. Adenomas with hemorrhage, infarction, and cyst formation were indistinguishable from those without these findings. CT was helpful in identifying the mass effect of macroadenomas; however, in microadenomas of all types CT abnormalities were uncommon. Thus, the diagnostic evaluation of the patient suspected of harboring a pituitary adenoma, particularly a microadenoma, must remain a joint effort based on clinical, radiographic, and endocrinologic data.

Adenoma↗

A prospective comparison of duplex sonography vs angiography of the vertebral arteries.

A prospective blind comparison was completed between duplex sonography and angiography of the vertebral arteries. Thirty-two vertebral arteries were studied for direction of flow, degree of origin plaque or stenosis, Doppler characteristics, and vessel size. The vertebral arteries were reliably identified by imaging their course from the subclavian artery into the transverse foramina and by identifying a Doppler signal similar in waveform to the internal carotid artery. With Doppler, a 90% accuracy was obtained for direction of blood flow. Nonvisualization of origins was primarily due to vessel depth and/or tortuosity. In 12 vessel origins that were well seen with both techniques, angiography and sonography agreed in two-thirds of the cases. In four cases, origin plaque was underestimated with duplex imaging. Interestingly, no Doppler frequency or velocity elevation was identified distal to significant stenoses. One false-positive diagnosis of occlusion occurred with sonography, in which a 99% origin stenosis resulted in no detectable Doppler signal. By comparing sonography with angiography, sonography was shown to be 80% accurate in determining vertebral artery size. Our preliminary results indicate that duplex scanning is a reasonably accurate screening technique for size, patency, and direction of blood flow in the vertebral arteries. Duplex evaluation of the vertebral artery origin was limited by vessel depth, tortuosity, and calcifications.

Adult↗

The behavior of Pantopaque on MR: in vivo and in vitro analysis.

MR imaging is considered by many to be the procedure of choice in imaging the spinal cord; yet we encountered an important pitfall of this procedure in the form of a patient with retained intraspinal Pantopaque. The results of this case are presented as well as those obtained in another patient with retained Pantopaque. Also described is the behavior of this contrast material when using in vitro imaging data obtained from a CSF/Pantopaque phantom. When T1-weighted imaging sequences are used, Pantopaque gives a high signal and CSF gives a low signal. With long repetition time, (e.g., 4000 ms), the CSF signal is high and the Pantopaque signal is not. With repetition time around 1000 to 2000, both may be isointense. The implications of these findings are discussed.

Adult↗

MR of Leigh's disease (subacute necrotizing encephalomyelopathy).

MR images of three patients with Leigh's disease (subacute necrotizing encephalomyelopathy) were compared with CT findings. In all patients typical lesions in the basal ganglia were identified with both MR and CT. In two patients MR permitted identification of additional lesions not detected with CT. In one patient progression of MR abnormalities over a 4-month period correlated well with clinical deterioration in neurologic status. T2-weighted images with a repetition time (TR) greater than 1950 msec and an echo time (TE) greater than or equal to 60 msec or inversion-recovery images with a 50-msec TE, 1213-msec inversion time, and 3000-msec TR were advantageous in identifying multiple necrotic lesions in the brainstem, deep gray matter, periventricular white matter, and cerebral cortex. In this series MR was more sensitive in detecting and localizing multifocal necrotic lesions of Leigh's disease than CT was, and thus may be a useful diagnostic tool for patients with the appropriate clinical and laboratory abnormalities.

Brain Diseases, Metabolic↗

Gadolinium-DTPA and MR imaging of pituitary adenoma: a preliminary report.

Gadolinium-DTPA MR imaging (Gd-MR), unenhanced MR imaging, and contrast-enhanced CT studies were compared prospectively in six patients with surgically confirmed pituitary adenomas and three patients without sellar pathology to determine the utility of Gd-MR in the diagnosis of pituitary adenoma. In normal patients, the pituitary gland, cavernous sinus, and infundibulum enhanced by T1 shortening after gadolinium. In adenoma patients, two of four focal lesions identified with contrast-enhanced CT were identified with Gd-MR, and one was identified with unenhanced MR. The earliest short repetition-time sequence performed after gadolinium injection was best for focal lesion detection. Normal cavernous sinus enhancement by gadolinium made identification of cavernous sinus extension of adenoma difficult. Infundibulum displacement was better seen with contrast-enhanced CT (two vs one); however, unenhanced and Gd-MR were better than contrast-enhanced CT for demonstrating chiasmal compression (four vs three). Contrast-enhanced CT, Gd-MR, and plain MR were equally able to identify gland enlargement, sellar floor erosion, and abnormalities of the diaphragma sellae. In this preliminary series, we found Gd-MR to be promising for imaging adenomas; however, modifications in Gd-MR technique including thinner slices and immediate scanning after gadolinium injection are necessary for the best detection of focal lesions.

Adenoma↗

A phantom study of intracranial CSF signal loss due to pulsatile motion.

MR imaging of the head often reveals localized areas of decreased signal intensity (flow voids) within the CSF. These flow voids are caused by turbulence within the CSF resulting from its pulsatile back-and-forth flow through the cerebral aqueduct and foramina. We describe a phantom that mimics the essential features of the CSF flow, and discuss its use in studying the dependence of the CSF flow void (CFV) on spin-echo (SE) and inversion-recovery pulse sequence parameters. The phantom had fluid-filled spaces to represent ventricles, and channels connecting these spaces to represent the aqueduct and foramina. A pump pushed the fluid in a pulsing manner through the phantom at various rates. The CFV was quantified by measuring signal loss relative to nonflowing fluid. The CFV did not appear to depend on repetition time or inversion time. The CFV was, however, strongly dependent on echo time (TE), and for single-echo SE sequences CFV became less severe as TE decreased. An even-echo rephasing effect was observed for multiecho sequences. Slice thickness and field of view also affected the appearance of the CFV, as did gating with respect to the pulsatile motion. These results imply that TE, field of view, slice thickness, and gating must be considered when using the appearance or absence of the CFV in diagnosis.

Cerebrospinal Fluid↗