Improvement of radiotherapy treatment delivery accuracy using an electronic portal imaging device.

Reliable application of advanced external beam techniques for the treatment of patients with cancer, such as intensity modulated radiotherapy, requires an adequate quality assurance programme for the verification of the dose delivery. Accurate patient positioning is mandatory because of the steep dose gradients outside the tumour volume. Owing to the increased complexity of the treatment planning and delivery techniques, verification of the dose delivery before and during the actual patient treatment is equally important. For this purpose, a quality assurance programme has been established in our clinic that is primarily based on measurements with electronic portal imaging devices. To minimise systematic set-up errors, the patient positioning is measured in the first few treatment fractions and a set-up correction is applied in the subsequent ones. Before the first treatment fraction, portal dose measurements are performed for each treatment field with the electronic portal imaging device to verify that the planned fluence distribution is correctly delivered at the treatment unit. Dosimetric measurements are also performed during patient treatment to derive the actually delivered fluence maps. By combining this information with knowledge on the patient set-up, the delivered 3-D dose distribution to both the tumour and sensitive organs may be assessed. However, for the highest accuracy, exact knowledge on the (internal) patient geometry during treatment, e.g. using a cone-beam CT, is required.

Humans↗

A novel approach to accurate portal dosimetry using CCD-camera based EPIDs.

A new method for portal dosimetry using CCD camera-based electronic portal imaging devices (CEPIDs) is demonstrated. Unlike previous approaches, it is not based on a priori assumptions concerning CEPID cross-talk characteristics. In this method, the nonsymmetrical and position-dependent cross-talk is determined by directly imaging a set of cross-talk kernels generated by small fields ("pencil beams") exploiting the high signal-to-noise ratio of a cooled CCD camera. Signal calibration is achieved by imaging two reference fields. Next, portal dose images (PDIs) can be derived from electronic portal dose images (EPIs), in a fast forward-calculating iterative deconvolution. To test the accuracy of these EPI-based PDIs, a comparison is made to PDIs obtained by scanning diode measurements. The method proved accurate to within 0.2+/-0.7% (1 SD), for on-axis symmetrical and asymmetrical fields with different field widths and homogeneous phantom thicknesses, off-axis Alderson thorax fields and a strongly modulated IMRT field. Hence, the proposed method allows for fast, accurate portal dosimetry. In addition, it is demonstrated that the CEPID cross-talk signal is not only induced by optical photon reflection and scatter within the CEPID structure, but also by high-energy back-scattered radiation from CEPID elements (mirror and housing) towards the fluorescent screen.

Algorithms↗

Characteristics relevant to portal dosimetry of a cooled CCD camera-based EPID.

Our EPIDs have recently been equipped with Peltier-cooled CCD cameras. The CCD cooling dramatically reduced deteriorating effects of radiation damage on image quality. Over more than 600 days of clinical operation, the radiation induced noise contribution has remained stable at a very low level (1 SD < or = 0.15% of the camera dynamic range), in marked contrast with the previously used noncooled cameras. The camera response (output signal versus incident EPID radiation exposure) can be accurately described with a quadratic function. This response reproduced well, both in short and long term (variation < 0.2% respectively < 0.4% (1 SD)), rendering the cooled camera well-suited for EPID dosimetry applications.

Cold Temperature↗

A new approach to off-line setup corrections: combining safety with minimum workload.

Off-line patient setup correction protocols based on electronic portal images are an effective tool to reduce systematic patient setup errors. Recently, we have introduced the no action level (NAL) protocol which establishes a significant error reduction at a very small workload. However, this protocol did not include an explicit verification of the applied setup corrections. Systematic mistakes in the execution of setup corrections (e.g., a setup correction is always executed in the +X direction whereas a correction in the -X direction was prescribed) may introduce large systematic setup errors (irrespective of the setup protocol) and may seriously impair treatment outcome. We have therefore extended the NAL protocol with a correction verification (COVER) stage, solely aimed at detecting such mistakes. In short, COVER tests the magnitude of the postcorrection setup error in each relevant direction. If these residue errors are below the acceptance threshold T, no more electronic portal images are required and the protocol has finished. If not, the origin of this result should be investigated; if no obvious mistakes are present, the procedure is repeated for one more treatment fraction. If the residue setup errors are confirmed to be larger than T, the entire protocol is restarted. Using both Monte Carlo simulations and analytical calculations, we performed a risk analysis and evaluated the workload for various choices of T. A threshold T = 3 x sigma(r), where sigma(r) is the mean standard deviation of the random setup errors, ensured that (1) COVER introduces only a small additional workload (1.05 measurement per patient, while the absolute minimum is 1.0) and (2) serious correction mistakes are detected with high probability. Even if setup corrections are wrongly applied in each patient (worst case scenario), COVER ensures that the final distribution of systematic errors is not wider than the precorrection distribution of systematic errors; for realistic frequencies of correction mistakes (<< 1 per patient) this distribution becomes much more narrow. The combination of NAL and COVER thus provides a highly efficient as well as safe method to reduce systematic setup errors.

Algorithms↗