PubMed Health⌕ Search

Biomedical subjects

J C Klein

Publications and source records attributed to J C Klein.

At least 19 recordsLinked to original sources

[Fatal familial insomnia: case presentation and discussion of typical clinical and imaging findings].

Fatal familial insomnia (FFI) is a hereditary prion disease caused by a mutation in codon 178 of the prion protein gene PRNP on chromosome 20. It is characterized by disturbed night sleep, resulting in daily vigilance perturbations and a variety of other neurological symptoms. We present the case of a 46-year-old woman deteriorating despite immunosuppressive treatment which was initiated suspecting cerebral vasculitis as the cause of her progressive neurological symptoms. The correct diagnosis was established only post mortem. Based on the case presented here, we discuss typical clinical symptoms and imaging findings. In particular, we outline how modern diagnostic methods such as positron emission tomography with [(15)O]H(2)O and [(18)F]FDG and single photon emission computed tomography can add valuable information to results from conventionally performed imaging techniques and genetic testing.

Fatal Outcome↗

Dementia in Parkinson disease: functional imaging of cholinergic and dopaminergic pathways.

OBJECTIVE: To assess neurochemical deficits in patients with Parkinson disease (PD) associated dementia (PDD) in vivo. METHODS: The authors performed combined PET with N-[11C]-methyl-4-piperidyl acetate (MP4A) and 18F-fluorodopa (FDOPA) for evaluation of cholinergic and dopaminergic transmitter changes in 17 non-demented patients with PD and 10 patients with PDD. Data were compared to 31 age-matched controls by a combined region-of-interest and voxel-based Statistical Parametric Mapping analysis. RESULTS: The striatal FDOPA uptake was significantly decreased in PD and PDD without differences between the groups. The global cortical MP4A binding was severely reduced in PDD (29.7%, p < 0.001 vs controls) and moderately decreased in PD (10.7%, p < 0.01 vs controls). The PDD group had lower parietal MP4A uptake rates than did patients with PD. Frontal and temporo-parietal cortices showed a significant covariance of striatal FDOPA reduction and decreased MP4A binding in patients with PDD. CONCLUSIONS: While non-demented patients with Parkinson disease had a moderate cholinergic dysfunction, subjects with Parkinson disease associated dementia (PDD) presented with a severe cholinergic deficit in various cortical regions. The finding of a closely associated striatal FDOPA and cortical MP4A binding reduction suggests a common disease process leading to a complex transmitter deficiency syndrome in PDD.

Acetates↗

Calibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients. Part 2. Superiority of the one-point calibration method.

UNLABELLED: Calibration, i.e. the transformation in real time of the signal I(t) generated by the glucose sensor at time t into an estimation of glucose concentration G(t), represents a key issue for the development of a continuous glucose monitoring system. OBJECTIVE: To compare two calibration procedures. In the one-point calibration, which assumes that I(o) is negligible, S is simply determined as the ratio I/G, and G(t) = I(t)/S. The two-point calibration consists in the determination of a sensor sensitivity S and of a background current I(o) by plotting two values of the sensor signal versus the concomitant blood glucose concentrations. The subsequent estimation of G(t) is given by G(t) = (I(t)-I(o))/S. RESEARCH DESIGN AND METHODS: A glucose sensor was implanted in the abdominal subcutaneous tissue of nine type 1 diabetic patients during 3 (n = 2) and 7 days (n = 7). The one-point calibration was performed a posteriori either once per day before breakfast, or twice per day before breakfast and dinner, or three times per day before each meal. The two-point calibration was performed each morning during breakfast. RESULTS: The percentages of points present in zones A and B of the Clarke Error Grid were significantly higher when the system was calibrated using the one-point calibration. Use of two one-point calibrations per day before meals was virtually as accurate as three one-point calibrations. CONCLUSION: This study demonstrates the feasibility of a simple method for calibrating a continuous glucose monitoring system.

Biosensing Techniques↗

Calibration of a subcutaneous amperometric glucose sensor. Part 1. Effect of measurement uncertainties on the determination of sensor sensitivity and background current.

The calibration of a continuous glucose monitoring system, i.e. the transformation of the signal I(t) generated by the glucose sensor at time (t) into an estimation of glucose concentration G(t), represents a key issue. The two-point calibration procedure consists of the determination of a sensor sensitivity S and of a background current I(o) by plotting two values of the sensor signal versus the concomitant blood glucose concentrations. The estimation of G(t) is subsequently given by G(t) = (I(t)-I(o))/S. A glucose sensor was implanted in the subcutaneous tissue of nine type 1 diabetic patients during 3 (n = 2) and 7 days (n = 7). For each individual trial, S and I(o) were determined by taking into account the values of two sets of sensor output and blood glucose concentration distant by at least 1 h, the procedure being repeated for each consecutive set of values. S and I(o) were found to be negatively correlated, the value of I(o) being sometimes negative. Theoretical analysis demonstrates that this phenomenon can be explained by the effect of measurement uncertainties on the determination of capillary glucose concentration and of sensor output.

Biosensing Techniques↗

Intestinal toxicity and carcinogenic potential of the food mutagen 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) in DNA repair deficient XPA-/- mice.

The effects of the food mutagen 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) were studied in DNA repair deficient XPA(-/-) mice. The nullizygous XPA-knockout mice, which lack a functional nucleotide excision repair (NER) pathway, were exposed to dietary concentrations ranging from 10 to 200 p.p.m. The results show that PhIP is extremely toxic to XPA(-/-) mice, even at doses 10-fold lower than tolerated by wild-type C57BL/6 mice. XPA(-/-) mice rapidly lost weight and died within 2 and 6 weeks upon administration of 200 and 100 p.p.m., respectively. Intestinal abnormalities like distended and overfilled ileum and caecum, together with clear signs of starvation, suggests that the small intestines were the primary target tissue for the severe toxic effects. Mutation analysis in XPA(-/-) mice carrying a lacZ reporter gene, indicated that the observed toxicity of PhIP might be caused by genotoxic effects in the small intestine. LacZ mutant frequencies appeared to be selectively and dose-dependently increased in the intestinal DNA of treated XPA(-/-) mice. Furthermore, DNA repair deficient XPC(-/-) mice, which are still able to repair DNA damage in actively transcribed genes, did not display any toxicity upon treatment with PhIP (100 p.p.m.). This suggests that transcription coupled repair of DNA damage (PhIP adducts) in active genes plays a crucial role in preventing the intestinal toxicity of PhIP. Finally, PhIP appeared to be carcinogenic for XPA(-/-) mice at subtoxic doses. Upon treatment of the mice for 6 months with 10 or 25 p.p.m. PhIP, significantly increased tumour incidences were observed after a total observation period of one year. At 10 p.p.m. only lymphomas were found, whereas at 25 p.p.m. some intestinal tumours (adenomas and adenocarcinomas) were also observed.

Adenocarcinoma↗

Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring.

The changes in plasma glucose concentration and in interstitial glucose concentration, determined with a miniaturized subcutaneous glucose sensor, were investigated in anesthetized nondiabetic rats. Interstitial glucose was estimated through two different calibration procedures. First, after a glucose load, the magnitude of the increase in interstitial glucose, estimated through a one-point calibration procedure, was 70% of that in plasma glucose. We propose that this is due to the effect of endogenous insulin on peripheral glucose uptake. Second, during the spontaneous secondary decrease in plasma glucose after the glucose load, interstitial glucose decreased faster than plasma glucose, which may also be due to the effect of insulin on peripheral glucose uptake. Third, during insulin-induced hypoglycemia, the decrease in interstitial glucose was less marked than that of plasma glucose, suggesting that hypoglycemia suppressed transfer of glucose into the interstitial tissue; subsequently, interstitial glucose remained lower than plasma glucose during its return to basal value, suggesting that the stimulatory effect of insulin on peripheral glucose uptake was protracted. If these observations obtained in rats are relevant to human physiology, such discrepancies between plasma and interstitial glucose concentration may have major implications for the use of a subcutaneous glucose sensor in continuous blood glucose monitoring in diabetic patients.

Animals↗

A multimodal registration algorithm of eye fundus images using vessels detection and Hough transform.

Image registration is a real challenge because physicians handle many images. Temporal registration is necessary in order to follow the various steps of a disease, whereas multimodal registration allows us to improve the identification of some lesions or to compare pieces of information gathered from different sources. This paper presents an algorithm for temporal and/or multimodal registration of retinal images based on point correspondence. As an example, the algorithm has been applied to the registration of fluorescein images (obtained after a fluorescein dye injection) with green images (green filter of a color image). The vascular tree is first detected in each type of images and bifurcation points are labeled with surrounding vessel orientations. An angle-based invariant is then computed in order to give a probability for two points to match. Then a Bayesian Hough transform is used to sort the transformations with their respective likelihoods. A precise affine estimate is finally computed for most likely transformations. The best transformation is chosen for registration.

Algorithms↗

Lack of mammalian mutagenicity of the potent bacterial mutagen tris(2,3-dibromopropyl) phosphate and its metabolite 2-bromoacrolein.

The flame retardant tris(2,3-dibromopropyl)phosphate (Tris-BP) and its metabolite 2-bromoacrolein (2BA) are very potent bacterial mutagens in Salmonella typhimurium (S. typhimurium) TA 100. In this study, we showed that 2BA and Tris-BP are also mutagenic in S. typhimurium TA 104, which detects mutations at AT base pairs, while TA 100 detects mutations at CG basepairs. We also studied the mutagenicity of 2BA in mammalian cells in vitro and in the rat in vivo. Firstly, 2BA was tested in the human lymphoblastoid cell line TK6. The results showed that there was no increase in mutation frequency at the hprt locus, whereas there was a large decrease in cell survival. Secondly, a shuttle vector system was used to study the induction of mutations by 2BA:DNA adducts. The vector was modified by insertion of a single-stranded oligonucleotide containing on average one 2BA:DNA adduct. No increase in mutation frequency above background was detected after replication of this vector in SV40 transformed normal human fibroblasts. Because the liver is a major site for bioactivation of Tris-BP to 2BA in vivo, we tested the initiating capacity of Tris-BP in the rat liver in a modified Solt & Farber initiation and promotion system. Administration of Tris-BP resulted in a small increase in the number of preneoplastic gamma-glutamyl-transpeptidase positive (GGT+) foci in the liver compared to control animals (only significant in the lowest size class). Modification of the experimental protocol by performing partial hepatectomy 24 h after the administration of Tris-BP, did not increase the number of GGT+ or glutathione S-transferase-P (GST-P+) positive foci above the control level. Taken together, these results indicate that, in spite of a high mutagenicity in S. typhimurium, 2BA and Tris-BP have low or negligible mutagenic effects in mammalian systems. The lack of mutagenic activity may explain why Tris-BP is not a carcinogen in the rat liver.

Acrolein↗

Continuous glucose monitoring in the free-moving rat.

The aim of this work was to set up an experimental model of glycemic fluctuations for assessing in the conscious freely moving rat, the performance of a continuous glucose-monitoring system, using a pocket-calculator-size electronic control unit and a miniaturized subcutaneous glucose sensor. The well-known triphasic glycemic pattern following streptozotocin injection (initial peak and secondary hypoglycemia preceding the establishment of permanent hyperglycemia) was used as a way to obtain spontaneous changes in blood glucose level over a wide concentration range. This report demonstrates that streptozotocin injection produced highly reproducible changes in the current generated by the sensor: an initial peak and a secondary nadir, during which blood sampling provided the evidence of hyperglycemia associated with immunoreactive hypoinsulinemia, and of hypoglycemia associated with hyperinsulinemia, respectively. This reproducible experimental model should be valuable for the assessment of a continuous glucose-monitoring system.

Animals↗

A user-friendly method for calibrating a subcutaneous glucose sensor-based hypoglycaemic alarm.

A crucial step in developing a glucose monitoring system using a subcutaneous implanted glucose sensor is the transformation of the sensor signal (a current) into an estimation of a blood glucose concentration. We have developed an Electronic Control Unit (ECU) able to recognize, before and after a glucose load, that the sensor current presents a plateau, thus triggering an alarm asking for blood glucose determination. The system, fed with these results, subsequently transforms the current into an estimation of glucose concentration by linear extrapolation based on the sensor sensitivity and the background current computed from the two sets of current and glycaemia values (two-point calibration). In addition, the system is able to trigger an alarm when this estimation decreases below a threshold that can be set by the user. This system was evaluated in experiments performed in 12 normal rats. The quality of the calibration was assessed by comparing, by error grid analysis, the data displayed on the liquid-crystal display of the ECU to concomitant plasma glucose concentration determined at frequent intervals, 65 +/- 6 and 26 +/- 5% of the values were in zones A (good) and B (acceptable estimation) of the grid, respectively. The system was set to trigger an alarm when the estimation of glucose concentration decreased below 70 mg/dl. Following an insulin administration, the alarm was triggered when the system displayed a 64 +/- 2 mg/dl glucose concentration. The concomitant plasma glucose concentration was 59 +/- 5 mg/dl (NS). In conclusion, this work validates experimentally the new, user-friendly method for calibrating the glucose sensor integrated into the ECU, based on an automatic detection of plateaus. The quality of the sensor calibration performed with this procedure is compatible with the appropriate functioning of this continuous glucose monitoring system, which was demonstrated by its ability to detect mild hypoglycaemia following insulin injection.

Animals↗

Use of a subcutaneous glucose sensor to detect decreases in glucose concentration prior to observation in blood.

The development of a hypoglycemic alarm system using a subcutaneous glucose sensor implies that a decrease in blood glucose is rapidly followed by a decrease in the signal generated by the sensor. In a first set of experiments the linearity and the kinetics of the response of sensors implanted in the subcutaneous tissue of normal rats were investigated during a progressive increase in plasma glucose concentration: the sensitivities determined between 5 and 10 mM and between 10 and 15 mM were not significantly different, and a 5-10 min delay in the sensor's response was observed. In a second set of experiments, performed in diabetic rats, the kinetics of the decrease in subcutaneous glucose concentration following insulin administration was monitored during a decrease in plasma glucose level, from 15 to 3 mmol/L. During the 20 first min following insulin administration, the sensor monitored glucose concentration in subcutaneous tissue with no lag time. Subsequently, the decrease in the estimation of subcutaneous glucose concentration preceded that of plasma glucose. This phenomenon was not observed when the same sensors were investigated in vitro during a similar decrease in glucose concentration and may be due to a mechanism occurring in vivo, such as the effect of insulin on glucose transfer from the interstitial space to the cells surrounding the sensor. It reinforces the interest of the use of implantable glucose sensors as a part of a hypoglycemic alarm.

Scintillation Counting↗

Irradiated (15N)DNA as an internal standard for analysis of base-oxidized DNA constituents by isotope dilution mass spectrometry.

A simple and convenient procedure for the preparation of isotopically labeled DNA enriched in oxidized deoxynucleosides is described. 15N-Labeled DNA was isolated from Escherichia coli cells grown in an isotopically enriched medium, and the level of oxidative damage was increased by in vitro irradiation under oxygen. The resulting DNA was hydrolyzed and subsequently analyzed by GC/MS. Results indicated that the DNA was 99% 15N-enriched and that 1% of the total 2'-deoxyguanosine was converted into 8-hydroxy-2'-deoxyguanosine (8-OHdG). When applied to the analysis of 8-OHdG, [15N]DNA as internal standard gave a better reproducibility (CV, 7.9%; n = 5) as compared to the monomeric 8-[18O]hydroxy-2'-deoxyguanosine (CV, 16%; n = 4). Background levels of 8-OHdG in rat colon DNA determined with [15N]DNA and 8-18OHdG as internal standard were 26 +/- 11 and 15 +/- 7 8-OHdG per 10(6) deoxynucleosides, respectively.

Animals↗

Role of nucleotide excision repair in processing of O4-alkylthymines in human cells.

O4-Alkylthymines have been implicated as potential carcinogenic DNA lesions. We have studied the effects of O4-methylthymine, O4-ethylthymine, and O4-n-propylthymine in a model system in which a single lesion was located at a defined position on a SV40-based shuttle vector and have found large differences in the effects of these lesions in repair-proficient and nucleotide excision repair-deficient cells. In repair-competent human HeLa cells, normal fibroblasts, and XP-A (2OS) revertant cells, all 3 residues were highly mutagenic; a mutation frequency of approximately 20% was found for both O4-methylthymine and O4-ethylthymine, whereas that of O4-n-propylthymine was approximately 12%. These frequencies were independent of the activity of the O6-alkylguanine DNA alkyltransferase. All three O4-alkylthymines induced T-->C transitions exclusively. In nucleotide excision repair-deficient XP-A cells, however, these lesions were not mutagenic but strongly inhibited plasmid replication (> 90%). These results indicate that O4-alkylthymines are efficiently recognized by the nucleotide excision repair system and cause a complete cessation of plasmid replication if this system is deficient. Nevertheless, proficiency in the nucleotide excision repair pathway correlates with a high frequency of mutation induction by these lesions.

Alkyl and Aryl Transferases↗

Reduction of acetaminophen interference in glucose sensors by a composite Nafion membrane: demonstration in rats and man.

Amperometric glucose sensors typically monitor the production of hydrogen peroxide generated in the course of the enzymatic oxidation of glucose. At the applied potential necessary to oxidize the peroxide produced, other species are also electroactive and contribute to the signal. Interference of ascorbate or urate has been effectively eliminated, but that resulting from the widely used analgesic acetaminophen is not. The aim of this work was to reduce this interference, which was found to be possible by introducing a membrane constructed of Nafion. We compared the in vitro sensitivity to acetaminophen of five Nafion sensors with that of five non-Nafion sensors with identical glucose sensitivity (2.0 +/- 0.4 vs 1.9 +/- 0.1 nA.mmol-1.l-1, NS): sensitivity to acetaminophen was 12.2 +/- 2.7 vs 30.8 +/- 6.3 nA.mmol-1.l-1, respectively (p < 0.05). These sensors were tested in rats by implanting in each animal one Nafion and one non-Nafion sensors. The in vivo sensitivity to glucose was similar (0.33 +/- 0.09 vs 0.30 +/- 0.05 nA.mmol-1.l-1, NS). The current generated by an acetaminophen infusion (plasma acetaminophen plateau = 140 +/- 10 mumol/l) was much decreased in the case of the Nafion sensor: 0.5 +/- 0.3 vs 2.0 +/- 0.7 nA, p < 0.05). Five Nafion sensors were implanted in the subcutaneous tissue of normal human volunteers who were given on oral dose of 500 mg acetaminophen.(ABSTRACT TRUNCATED AT 250 WORDS)

Acetaminophen↗